Danfoss

ETS 50 (034G0501) Danfoss Electric Expansion Valve

SKU 034G0501

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Danfoss

  • Product No.: 034G0501

  • Country of origin:United States

  • Product Type: Electric Expansion Valve

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The ETS 50 (034G0501) is a high-precision electric expansion valve (EEV) engineered for the precise injection of liquid refrigerant into evaporators for air conditioning and refrigeration systems. As a critical component in high-efficiency B2B thermal management solutions, the Danfoss 034G0501 (034G0501) utilizes a bipolar motor actuator to provide accurate flow control, which is essential for optimizing Superheat (SH) and reducing energy consumption. Its bi-flow capability makes it an ideal choice for heat pump systems, where refrigerant flow directions must be maintained with equal precision in both heating and cooling cycles. By integrating this valve, operators can ensure stable system performance and enhanced protection for compressors against liquid slugging.

Technical Configuration

The technical architecture of the ETS 50 series is centered on a balanced internal design that provides linear flow characteristics. The valve is driven by a precision stepper motor that translates electronic pulses from a controller into precise needle positioning. The 034G0501 configuration features a factory-installed 2 meter (6.6 ft) cable, simplifying integration into control panels. The internal mechanism is hermetically sealed to prevent refrigerant leakage, and the entire actuator assembly is rated at IP67, ensuring reliable operation in high-humidity environments or areas prone to condensation. Its bi-flow flow direction logic ensures that the valve maintains calibrated control regardless of the refrigerant path, a necessity for modern reversible HVAC units.

Technical Specifications

Feature Specification
Model ETS 50 (034G0501)
Brand Danfoss
Product Type Electric Expansion Valve (EEV)
Flow Direction Bi-flow
Actuator Type Bipolar Stepper Motor
Enclosure Rating IP67
Cable Length 2 m (6.6 ft)
Operating Temp -40 to 65 Celsius
Max Working Pressure 45.5 bar
Compatibility R410A, R407C, R404A, R134a, R22
Weight 1.0 kg
Shipping Weight 3.0 kg

Technical FAQs

What are the advantages of the Bi-flow capability in the 034G0501?

The bi-flow design allows the ETS 50 to regulate refrigerant flow in both directions with the same high degree of accuracy. This eliminates the need for two separate expansion valves and check valves in heat pump circuits, reducing system complexity and potential leak points.

Does this valve require a specific type of controller?

Yes, as a stepper motor valve, the 034G0501 requires a compatible electronic EKD or EKE series controller (or a third-party PLC with a bipolar stepper driver) to provide the necessary pulses for opening and closing the valve.

What is the significance of the IP67 enclosure rating?

The IP67 rating ensures the actuator and cable connection are completely dust-tight and protected against the effects of temporary immersion in water. This is vital for refrigeration applications where heavy frost and subsequent defrost cycles create a high-moisture environment.


Engineering & Installation Guide

  • Brazing Safety: During installation, it is imperative to use a wet cloth to wrap the valve body and keep the temperature below 100 Celsius. Excessive heat during the brazing process can damage the internal needle assembly and the stepper motor magnets.

  • Mounting Orientation: For the most reliable oil return and to prevent refrigerant liquid from pooling in the actuator, mount the valve with the motor housing in a vertical position (upward). Ensure there is sufficient clearance for the 2 meter cable to be routed without tension.

  • Electrical Driver Setup: When configuring the controller, ensure the bipolar drive settings match the Danfoss motor specifications (typically 100 mA RMS). Setting the current too high will cause the motor to overheat, while setting it too low will result in missed steps and inaccurate flow regulation.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States
Power source
AC-powered

Technical knowledge

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.