Product Overview

The EVD4903-E (EVD4903-E) is a high-performance DC drive controller within the classic Lenze 4900-series, engineered to provide precise speed and torque regulation for industrial DC motors. Delivering an adjustable output range of 310-420 V with current capacities spanning 3.5 to 25 A, this unit is a critical component for heavy-duty applications such as continuous steel casting, industrial paper mills, and plastic extrusion lines. In these high-stakes B2B environments, the EVD4903-E acts as the primary power regulator, translating 400 V mains input into controlled kinetic energy. Its robust German engineering ensures reliable operation in centralized control cabinets, where its ability to maintain constant motor flux and reactive current compensation is vital for reducing unplanned downtime and maximizing the operational lifespan of legacy DC motor assets.

Technical Configuration

The EVD4903-E architecture is designed around a fully controlled thyristor bridge configuration, optimized for 3-phase mains operation. It features integrated field supply and armature voltage regulation, providing superior linearity across the entire speed range. The hardware is built for durability, weighing 12.80 kg, which reflects the substantial copper and aluminum heat-sinking required for managing up to 25 A of continuous current. The internal control logic supports various feedback modes, including tachogenerator or armature voltage feedback, ensuring stability even under fluctuating load conditions. Its 12.8 cm depth is specifically tailored for space-efficient mounting on backplates, while the terminal layout facilitates straightforward wiring for both power electronics and low-voltage control signals.

Technical Specifications

Attribute Specification Details
Model EVD4903-E
Brand Lenze
Origin Germany
Product Range 4900-series
Input Voltage 3 x 400 VAC (50/60 Hz)
Output Armature Voltage 310 - 420 VDC
Rated Current Range 3.5 - 25 A
Weight 12.80 kg
Dimensions (Depth) 12.8 cm
Product Status Obsolete (Legacy Support)
Control Type Thyristor-controlled DC Drive
Commodity Code 85044095

Technical FAQs

How do I adjust the current limit on the EVD4903-E for a specific motor?

The current limit (I-max) is typically adjusted via on-board potentiometers or through the parameterization interface. You must calibrate this to the rated current on your motor nameplate to prevent thermal overload and protect the motor's commutator.

Is this controller compatible with both shunt-wound and permanent magnet DC motors?

Yes. While optimized for shunt-wound motors requiring an external field supply, the EVD4903-E can be configured for permanent magnet motors by disabling or not utilizing the internal field regulator terminals.

What are the primary indicators for a phase loss fault on this unit?

A phase loss or mains failure is typically signaled by an internal diagnostic LED or a dedicated fault relay output. This protection prevents the thyristor bridge from operating under unbalanced loads, which could otherwise damage the internal SCR modules.

Can I replace an EVD4903-E with a newer Lenze AC drive series?

Direct replacement is complex because this unit drives DC motors. Moving to a newer AC series would require replacing the motor itself or utilizing a high-power AC-to-DC conversion interface, which is rarely cost-effective compared to installing a refurbished or new-old-stock 4900-series unit.


Engineering & Installation Guide

For the EVD4903-E, a vertical mounting orientation on a solid metal backplane is mandatory to facilitate natural convection through the large internal heat sink. Maintain a minimum clearance of 150 mm above and below the unit for unobstructed airflow. Because DC drives generate significant brush-fire noise and electrical harmonics, use shielded motor cables and ensure a 360-degree ground connection at the cabinet entry point. To protect the thyristors against high-energy mains transients, the installation of a 3-phase line reactor is highly recommended. During maintenance, check for carbon dust accumulation around the terminals, especially in environments with high motor brush wear, as this can lead to creepage currents and tracking faults.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White Silver
Country of origin
Germany

Recently Viewed Products

Technical knowledge

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...

Single-Axis Motion Control Setup with CMZ Servo Drives

This tutorial explores the commissioning of a single-axis servo motion system using a CMZ SBD drive, covering hardware setup, axis scaling, homing configuration, and safe motion verification for...

Mitsubishi FX PLC Integration With FR-D700 VFD and HMI Control

This tutorial explains how Mitsubishi FX PLCs integrate with FR-D700 VFDs and HMI panels for forward/reverse motor control. It covers wiring logic, parameter configuration, ladder programming, and...