Product Overview

The GE IC670ALG630 (IC670ALG630) is a high-performance 8-channel analog input module designed for the GE Field Control decentralized I/O systemThis specialized module accepts 8 independent thermocouple or millivolt inputs, providing precise temperature monitoring for critical industrial processes such as power generation, chemical refining, and metal processingBy converting analog thermal signals into a 16-bit digital format (15 bits plus sign), the IC670ALG630 ensures high-resolution data acquisition, which is essential for maintaining system stability and reducing energy-intensive thermal fluctuations. Its ability to interface directly with various thermocouple types without external converters makes it a cost-effective solution for large-scale distributed temperature sensing.

Technical Configuration

The module architecture is built around a solid-state, optically-coupled multiplexer and an internal microprocessor that handles scaling, linearization, and advanced diagnostics.

  • Input Versatility: Supports a wide range of thermocouples including Types J, K, T, E, S, R, B, N, G, C, D, and Platinel II.
  • Cold Junction Compensation (CJC): Offers four flexible methods—Local (via thermistor), Remote (via BIU), Fixed (configured value), or None.
  • Data Processing: Features self-calibration at power-up and every minute thereafter to compensate for ambient temperature shifts.
  • Intelligent Diagnostics: Automatically detects and reports open thermocouple circuits, over-range/under-range conditions, and high/low alarm levels for each channel.
  • Configurable Sampling: Users can select data acquisition rates based on 50 Hz or 60 Hz line frequencies to optimize normal mode noise rejection

Technical Specifications

Attribute Specification
Model

IC670ALG630


Brand GE (General Electric)
Series

Field Control


Module Type

Thermocouple Analog Input


Number of Channels

8 (Individually configurable)


Resolution

15 bits + sign


Origin USA
Weight 0.38 kg
Dimensions 135 x 45 x 100 mm
Operating Temp

0 to 55 deg C ambient


Power Consumption

195 mA maximum from BIU


Isolation

1500 VAC (Input to Logic/Frame Ground)


Scan Time (60 Hz)

Approximately 60 ms per point


Technical FAQs

How is data reported in the PLC memory?

Each channel can be configured to report either linearized temperature (in tenths of degrees Celsius or Fahrenheit) or raw millivolt values (reported as 1/100 of a millivolt).

What happens if a sensor wire breaks during operation?

Unless suppressed in the configuration, the module performs an "Open Thermocouple" check every time a channel is readIf a break is detected, a diagnostic bit is set in the discrete input table, and further processing of that channel is halted to prevent false readings.

Can this module operate without a separate power supply?

Yes, this module does not require a separate field power supply; it draws its required operating current (up to 195 mA) directly from the Bus Interface Unit (BIU) backplane.


Engineering & Installation Guide

  • Cold Junction Accuracy: To ensure maximum precision when using local compensation, use the Thermocouple Terminal Block (IC670CHS004)If using standard terminal blocks, a 10K Ohm BetaTHERM thermistor must be installed at the terminals to avoid erroneous temperature reporting.
  • Thermal Management: Avoid installing the IC670ALG630 and its terminal blocks in the same cabinet as high heat-dissipation assembliesTemperature transients near the terminal connections can introduce CJC errors; maintaining a stable ambient environment is key to the +/-0.25 deg C CJC accuracy.
  • Noise Mitigation: The module provides 120dB of Common Mode Rejection. For best results, use shielded thermocouple extension wire and terminate the shield at the terminal block ground. Ensure the DIN rail is properly grounded to chassis ground to facilitate the assembly’s internal grounding path.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Field Control IC670ALG630 Thermocouple Input Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...