General Electric

GE IS200TSVOH1BDC Mark VI Speedtronic Servo Termination Board

SKU IS200TSVOH1BDC

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric

  • Product No.: IS200TSVOH1BDC

  • Country of origin:United States

  • Product Type: Servo Termination Board

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 560g

  • Dimensions: 33cm x 17.7cm x 2.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The IS200TSVOH1BDC is a specialized servo termination board manufactured by General Electric as part of the Mark VI Speedtronic turbine control system series. This terminal board acts as the foundational structural interface layer linking external turbine instrumentation—such as electro-hydraulic servo valves and Linear Variable Differential Transformers (LVDTs)—to the main internal VME rack control cards. By establishing direct signal routing paths, the IS200TSVOH1BDC handles the clean transmission of valve current regulation demands, pulse rate flow signals, and critical LVDT feedback loops while minimizing single-point interface failures across automated steam or gas turbine systems.

Engineered to perform in demanding power generation environments, the IS200TSVOH1BDC features robust terminal blocks that accommodate stable, field-pluggable electrical wiring connections. The module coordinates with active servo processor boards to support real-time position tracking, sensor excitation control, and automated loop diagnostic synchronization under both simplex and Triple Modular Redundant (TMR) control architectures.

Features

  • Dedicated Actuator Loop Termination: Expressly designed to provide secure termination points for multi-channel electro-hydraulic actuator servo control wiring.
  • LVDT Instrumentation Support: Facilitates accurate signal mapping for high-frequency LVDT excitation outputs and position feedback tracing inputs.
  • Pluggable Barrier Blocks: Outfitted with heavy-duty, barrier-type terminal block rows that maintain solid contact pressure and can be unplugged for fast component testing or replacement.
  • Dual Architecture Configuration: Fully compatible with simplex configurations and fault-tolerant Triple Modular Redundant system layouts.
  • Industrial Noise Suppression: Component orientation and path trace layouts are optimized to protect delicate analog instrumentation data from local electromagnetic interference.

Applications

  • Mark VI Speedtronic steam and gas utility turbine control installations
  • Field wiring termination for electro-hydraulic servo valve loop actuators
  • Interface coupling for LVDT position feedback and pulse rate flow sensors

Technical Specifications

Item Description / Value
Manufacturer General Electric / GE Energy
Series Mark VI Speedtronic
Model IS200TSVOH1BDC
Base Hardware Part Number IS200TSVOH1B
Product Type Servo Termination Board
System Redundancy Support Simplex and Triple Modular Redundant (TMR)
Terminal Block Style Pluggable, barrier-type blocks
Interface Compatibility Electro-hydraulic servo valves and LVDT sensors

 

Installation Guidelines

  • Field Terminal Connection: Secure the field instrumentation and actuator wiring leads into the matching pluggable barrier terminal slots on the IS200TSVOH1BDC card face. Tighten all screw contacts to industry standard specifications to guarantee continuity.
  • Interconnecting Cable Routing: Utilize the specified multi-pin computer-grade ribbon cables with D-type connectors to bridge the IS200TSVOH1BDC board with its designated VME rack control counterpart.
  • Electrostatic Discharge Mitigation: Ensure a verified electrostatic grounding strap is attached to the technician before executing any mounting, handling, or connection changes on the module.

FAQ

What is the core purpose of this termination board in the control loop?

The board serves as the structural wiring interface between field devices, such as electro-hydraulic servo valves or LVDT sensors, and the internal VME rack control electronics.

Does the device support fault-tolerant system setups?

Yes, the board is fully compatible with both single-channel simplex control architectures and high-availability Triple Modular Redundant systems.

What type of connection blocks are provided for field instrumentation wiring?

The card is equipped with pluggable, barrier-type terminal blocks that allow secure attachment and simple removal during system maintenance or field expansion.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
United States
Power source
DC Power

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.