General Electric

GE Multilin C60-K03-HKH-F8L-H67-M67-P6D Breaker Protection System

SKU C60-K03-HKH-F8L-H67-M67-P6D

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric

  • Product No.: C60-K03-HKH-F8L-H67-M67-P6D

  • Country of origin:United States

  • Product Type: Protection Relays

  • Payment: T/T, Western Union

  • Weight: 4200g

  • Dimensions: 483 mm x 177 mm x 274 mm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The GE Multilin C60-K03-HKH-F8L-H67-M67-P6D is a substation-hardened breaker protection system designed for the integrated protection, control, and monitoring of circuit breakers. Part of the Universal Relay (UR) family, the GE Multilin C60-K03-HKH-F8L-H67-M67-P6D supports complex dual-breaker busbar configurations including breaker-and-a-half and ring bus arrangements. It features advanced automation capabilities via programmable logic engine (FlexLogic) and provides comprehensive digital I/O options alongside high-speed peer-to-peer communication. The device integrates high-accuracy AC metering, fault disturbance recording, and advanced IEC 61850 protocol support, making it suitable for direct integration into DCS and SCADA systems.

Features

  • Complete protection, control, and monitoring for single and dual breaker schemes in a single platform.
  • High-speed peer-to-peer communication for inter-device messaging and trip/close commands.
  • Integrated 7-inch color graphic HMI with bay mimic, annunciator functionality, and graphical phasor displays.
  • Powerful FlexLogic engine with up to 1024 lines of programmable logic for custom control automation.
  • Comprehensive protection functions including breaker failure, synchrocheck, multi-shot autoreclose, directional power, and overcurrent/thermal elements.
  • Advanced IEC 61850 Ed. 1 and Ed. 2 implementation, routable GOOSE (R-GOOSE), and PRP zero-failover redundancy support.
  • Continuous device health diagnostics monitoring internal hardware and CT/VT circuitry.
  • High-capacity disturbance recording including 1024 SOE events, COMTRADE waveform capture, and data logging.

Applications

  • Stand-alone circuit breaker monitoring and control.
  • Breaker-and-a-half and ring bus multiple breaker configuration management.
  • Automatic bus transfer schemes (main-tie-main) using a single device.
  • Substation automation and distributed bay control systems.

Ordering Information

Ordering Code Element Selected Option Description
Base Unit C60 Breaker Protection System Base Unit
CPU K RS485 + two 100BaseFX Eth, Multimode ST + one 10/100BaseT Eth, RJ-45
Software Options 03 Ethernet Global Data
Mount H Horizontal (19" rack) - Standard
User Interface KH Enhanced English Front Panel with User-Programmable Pushbuttons
Power Supply F 125/250 V AC/DC
CT/VT DSP 8L Sensitive Ground 4CT/4VT w/ enhanced diagnostics
Digital I/O Slot H H67 8 Form-A (No Monitoring) Outputs
Digital I/O Slot M M67 8 Form-A (No Monitoring) Outputs
Digital I/O Slot P P6D 16 Digital Inputs

Technical Specifications

Parameter Specification
Manufacturer GE Grid Solutions (GE Multilin)
Device Family Universal Relay (UR) Series
Power Supply Voltage 125/250 V AC/DC
CT/VT Input Configuration Sensitive Ground 4CT/4VT with enhanced diagnostics
Digital Outputs Form-A Outputs (Slot H and Slot M)
Digital Inputs Digital Inputs (Slot P)
Display 7-inch color graphic HMI with pushbuttons
Communication Protocols Modbus RTU/TCP, DNP 3.0, IEC 61850 Ed. 1/Ed. 2, IEC 60870-5-103/104, EGD, HTTP, SFTP, MMS
Time Synchronization IEEE 1588, SNTP
Event Recorder 1024 time-stamped events
Oscillography IEEE C37.111-1999/2013, IEC 60255-24 COMTRADE (64 digital, up to 40 analog channels)

Installation Guidelines

  • Mounting: Ensure proper panel cutouts for standard 19-inch rack horizontal installation.
  • Grounding: Solidly ground the relay frame to the main station ground bus using the dedicated grounding terminal.
  • Wiring: Connect CT and VT secondary circuits securely using verified terminal wiring diagrams. Ensure polarity alignment for directional power and overcurrent elements.
  • Communication: Connect Ethernet networks using multimode ST fiber cables for 100BaseFX connections or RJ-45 copper cables for 10/100BaseT connections. Maintain shield integrity on RS485 serial buses.
  • Power Connection: Verify control voltage matches the 125/250 V AC/DC rating before applying power to the terminal blocks.

FAQ

What primary functions does the device perform in substation automation?

The device provides complete integrated protection, control, and monitoring for circuit breakers, supporting configurations like breaker-and-a-half and ring bus schemes.

Which communication protocols are supported by the unit?

It supports IEC 61850, Modbus RTU/TCP, DNP 3.0, IEC 60870-5-103/104, Ethernet Global Data (EGD), and standard file transfer protocols.

How does the system record fault events for troubleshooting?

It features a sequence of events recorder capturing up to 1024 time-stamped events, alongside COMTRADE waveform oscillography and fault logging.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Multilin C60-K03-HKH-F8L-H67-M67-P6D Breaker Protection System

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Designing Current Shunt Measurements That Stay Accurate

A practical guide to current-shunt measurement covering resistor sizing, high-side and low-side placement, Kelvin sensing, error budgets, thermal effects, protection and commissioning tests.

Engineering Logix Produced and Consumed Tags

A field-ready guide to Logix produced and consumed tags, covering data contracts, RPI selection, connection status, stale-data handling, commissioning and controller-to-controller troubleshooting.

Commissioning AS-Interface Networks Without Guesswork

A practical AS-Interface commissioning method covering topology, power and voltage-drop checks, addressing, PLC mapping, fault tests and maintenance records for reliable actuator-sensor networks.

Selecting Line Reactors and Output Filters for VFDs

Learn how line reactors, harmonic filters, output reactors, dV/dt filters, and sine filters address different VFD power-quality and motor-cable problems—and how to select them safely.

Light-On and Dark-On Photoelectric Sensor Logic

Learn how light-on and dark-on photoelectric sensor modes interact with through-beam, retroreflective, and diffuse sensing, PNP/NPN wiring, PLC logic, commissioning, and fault detection.

Designing H-Bridge Motor Drives Without Shoot-Through

A practical guide to H-bridge motor drives covering switching states, dead time, inductive current paths, PWM choices, protection, PCB layout, PLC interfacing, and staged commissioning tests.