General Electric

GE Multilin UR-8HH UR Series CT/VT Module

SKU UR-8HH

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric

  • Product No.: UR-8HH

  • Country of origin:Canada

  • Product Type: CT/VT Input Module 

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 177.0 mm x 482.6 mm x 234.0 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The GE Multilin UR-8HH is an engineering-grade analog input module designed for the UR Series protection relay platform. Engineered to process critical alternating current signals, the UR-8HH function delivers a dedicated high-density Standard 8CT configuration that manages eight current transformer inputs on a single slot card. It operates by interfacing directly with primary power system lines via external current transformers, providing comprehensive current measurement coverage across multiple zones or parallel three-phase circuits without requiring auxiliary intermediate CT components. By supporting versatile, software-configurable 1A / 5A ground current transformer settings, the module enables precision ground and phase fault monitoring across diverse low-voltage, medium-voltage, and high-voltage electrical substation operations. This module communicates directly via the system internal bus to feed raw high-speed digitized analog samples to the primary CPU processor, supporting advanced protection elements, true RMS metering, oscillography capture, and detailed current harmonic tracking.

Features

  • Provides a compact high-density hardware architecture housing 8 Current Transformer (8CT) analog inputs within one full-height rack slot.
  • Features dual-rated secondary compatibility supporting both 1 A and 5 A standard current transformer secondary loops.
  • Implements direct high-speed analog-to-digital signal processing feeding synchronous samples into the relay internal calculation path.
  • Eliminates the need for external auxiliary current transformers through software-adjustable internal scale matching.
  • Integrates automatic mechanical shorting mechanisms across the external CT circuitry to guarantee technician safety during module withdrawal sequences.
  • Designed with distinctive blue identification labels and explicit safety warning markers to prevent system mismatching with legacy CPU architectures.

Applications

  • Multi-winding transformer differential protection configurations within utility substations.
  • High-density current monitoring for ring-bus configurations and breaker-and-a-half power distribution schemes.
  • Comprehensive ground fault, neutral current tracking, and phase-overcurrent monitoring networks.
  • Raw current waveform capture and high-resolution dynamic oscillography logging for power system diagnostic applications.

Technical Specifications

Parameter Category Specification Details
Manufacturer GE Multilin (General Electric) 
Country of Origin Canada 
Module Type CT/VT Input Module 
Input Configuration Standard 8 Current Transformers (8CT) 
Supported CT Rating 1 A and 5 A (Ground and Phase CT inputs)
System Compatibility UR Series Hardware (CPU Codes 9E and higher) 
Sampling Performance 64 samples per power cycle for precise true RMS metering 
Data Diagnostics Integrates with internal 1024-event recorder and 64 oscillography records 
Hardware Keying Blue identification label matching with strict warning verification 
Circuit Safety Protection Automatic internal shorting of external CT secondary loops upon card extraction 

Connections/Interfaces

The rear terminal layout of the UR Series uses a structured three-character coordinate identification code assigned based on the selected slot housing the UR-8HH card.

  • Current Transformer Screw Terminals: High-torque block headers equipped with dedicated underlying shorting bars designed to safely route continuous AC current loop configurations.
  • Dedicated Channel Mapping: Pin configurations split across eight distinct current input channels, each accepting dual phase-polarity (Inlet / Outlet) instrumentation paths.

Installation Guidelines

  • Power Precaution: Complete system control power must be physically disconnected and isolated from the main relay chassis prior to initiating any module insertion or withdrawal tasks.
  • Hardware Cohesiveness: The UR-8HH belongs to the modern generation of UR components. It must only be paired with a CPU module designated with code 9E or higher. Mixing this card with legacy CPU modules (e.g., 9A, 9C, 9D) will result in a fatal DSP ERROR or HARDWARE MISMATCH state.
  • Electrostatic Grounding: Technicians are strictly required to employ fully grounded anti-static wrist straps during handling to guard internal circuit layers against ESD stress.
  • Seating and Locking: Fully open the wide-angle hinge faceplate, align the card with the tracking slot, slide smoothly inside until the outer frame clears the lip, and then engage both top and bottom ejector/inserter clips simultaneously to fully lock the internal backplane connection.

FAQ

What happens if a UR-8HH module is mixed with an older legacy CPU module?

The UR Series relay will fail to initialize, block standard protection functions, and immediately trigger a DSP ERROR or HARDWARE MISMATCH fault notification on the faceplate screen.

Is it safe to pull out a UR-8HH module while the primary CT circuits are energized?

Yes, because the module is manufactured with automatic mechanical shorting features that automatically close external current transformer loops upon card extraction. However, system control power must always be shut down prior to physical module removal.

What is the primary indicator used to identify this newer generation module from older versions?

The module is built with a bright blue identification label on its frame along with a high-visibility warning sticker specifying that the CPU and DSP module label colors must match.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Multilin UR-8HH UR Series CT/VT Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
Canada
Power source
AC-powered

Technical knowledge

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.