General Electric

GE Multilin UR-9NH / UR9NH UR Series CPU Module

SKU UR-9NH

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric

  • Product No.: UR-9NH

  • Country of origin:United States

  • Product Type: CPU Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 6cm x 19.5cm x 17.2cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The GE Multilin UR-9NH is a central processing unit module designed for the UR Series (Universal Relay) platform, acting as the core management, control, and computational processor for high-performance automation and protection devices like the T60 Transformer Protection System. This module handles severe protection algorithms, manages system logic via programmed algorithms, and drives interfaces between field variables and network devices.

The UR-9NH provides comprehensive processing and digital communication capabilities. On its integrated communications interface, it is equipped with a dual setup featuring an RS485 port alongside a high-speed 10/100Base-T Ethernet interface. This network assembly accommodates multiple key utility automation protocols, including Modbus TCP/IP and DNP 3.0, allowing efficient integration into industrial SCADA and modern substation communication architectures. Additionally, this specific module variant comes equipped with a wide-range, substation-hardened 125 / 250 V AC/DC power supply integrated into the hardware group. Constructed as part of GE Multilin's version 4.0x or higher hardware refreshes, it features a blue label on the faceplate to facilitate accurate field deployment and prevent hardware version mismatching across legacy systems.

Features

  • Advanced Central Processing: Drives the complete central logic execution, protection routines, and diagnostic procedures for compatible UR series relay chassis.
  • Versatile Connectivity: Equipped with a serial RS485 port combined with a 10/100Base-T Ethernet connector to facilitate high-speed industrial data communication.
  • Integrated Power Supply: Built with a high-voltage 125 / 250 V AC/DC primary power module embedded directly on the assembly.
  • EnerVista Software Compatibility: Interfaces seamlessly with EnerVista software tools for configuration, backup, tracing, and parameter setup via standard network links.
  • Distinct Visual Identification: Uses a vivid blue identification label to represent compatibility with modern high-speed DSP and CT/VT diagnostic cards.

Applications

  • Substation Grid Protection: Serves as the high-speed logic and processing core in systems like the B30 or T60 Transformer Protection System within power utility generation or transmission environments.
  • Substation SCADA Integration: Bridges field-level measurements and control indicators to network master stations over 10/100Base-T Ethernet or RS485 via Modbus or DNP 3.0 lines.
  • Industrial Plant Automation: Deployed in demanding power plant, mining, or manufacturing facilities requiring a robust central relay controller powered by standard 125 / 250 V AC/DC station grids.

Technical Specifications

Parameter Specification
Manufacturer GE Multilin 
Model UR-9NH 
Product Series UR Series (Universal Relay) 
Module Type CPU Module with Power Supply 
Communication Ports RS485 and 10/100Base-T Ethernet 
Supported Communication Protocols Modbus RTU, Modbus TCP/IP, DNP 3.0 
Integrated Power Supply Voltage 125 / 250 V AC/DC 
Hardware Release Level Version 4.0x or higher compatible 
Visual Identification Indicator Blue Module Label 
Manufacturing Location Markham, Ontario, Canada 

Installation Guidelines

  • Control Power Safety: Module withdrawal or insertion must only be initiated when the main control power feeding the relay chassis has been entirely isolated and verified dead.
  • Electrostatic Grounding: Technicians must utilize an approved electrostatic discharge (ESD) prevention wrist strap when touching internal cards or chassis parts to prevent electrostatic shock damage.
  • Hardware Label Validation: Verify the visual blue label on the CPU matches the blue label configuration of existing CT/VT or DSP components. Inserting mismatched cards across legacy tiers halts the device and generates a "DSP ERROR" or "HARDWARE MISMATCH" code.
  • Cable Disconnection: Unplug the 10/100Base-T Ethernet cable from the front/rear ports of the module before loosening mounting screws or attempting card withdrawal from the internal backplane.
  • Module Seating: Align the card along the designated enclosure tracks, slide carefully until fully locked into the backplane, and secure the top/bottom ejector clips into place.

FAQ

Can the UR-9NH module be hot-swapped while the system is under voltage?

No. Removing or inserting any card while control power is applied can cause equipment damage, personal injury, or unexpected device operation. Ensure control power is removed beforehand.

What network interface is provided on the UR-9NH card for Ethernet operations?

This module is equipped with a standard 10/100Base-T copper Ethernet interface alongside its traditional RS485 serial communication channel.

What indicates that the UR-9NH belongs to the modern hardware release platform?

The module is fitted with a distinctive blue label on its faceplate assembly, showing it belongs to version 4.0x or higher hardware families.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

GE Multilin UR-9NH / UR9NH UR Series CPU Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...