Description

The General Electric IC660TBA021 is a Genius I/O terminal assembly specifically engineered to support RTD (Resistance Temperature Detector) input blocks within industrial automation architectures. Operating on a 24/48 Volts DC nominal supply range, this terminal assembly provides reliable signal termination and interfacing capabilities for demanding process control and data acquisition environments. It is designed to seamlessly integrate with compatible Genius network interface modules, such as QBIM and PCIM, facilitating robust distributed I/O communications across the plant floor.

This terminal assembly features six individual RTD input circuits organized into three isolated, independent groups of two circuits each. It natively supports multiple sensor types—including platinum, nickel, and copper RTDs—and performs internal linearization based on the selected sensor profile. Temperature data is processed and reported directly to the system CPU in engineering units, delivering high-resolution feedback in tenths of degrees Celsius or Fahrenheit, tenths of ohms, or raw counts.

Engineered for high reliability and ease of maintenance, the IC660TBA021 includes factory calibration, eliminating the need for periodic field calibration procedures. The unit incorporates comprehensive built-in diagnostic capabilities that actively monitor for open wires, input shorts, high and low input alarms, wiring errors, and external faults, ensuring fast troubleshooting and maximum system uptime.

Features

  • Six RTD input circuits divided into three independent, isolated groups of two
  • Compatible with 24/48 Volts DC input power and signal ranges
  • Native support for platinum, nickel, and copper RTDs with automatic linearization
  • Factory-calibrated design requiring no manual adjustments or field calibration
  • Advanced onboard diagnostics for open wires, short circuits, wiring errors, and high/low alarms
  • Designed for seamless integration with Genius network interface modules including QBIM and PCIM

Applications

  • Distributed temperature monitoring and data acquisition
  • Process control systems in chemical and petrochemical plants
  • Power generation and turbine monitoring
  • Manufacturing automation and environmental testing chambers

Technical Specifications

Parameter Specification
Manufacturer General Electric
Catalog Number / SKU IC660TBA021
Product Type Genius Terminal Assembly
Series Genius I/O
Input Channels 6 RTD inputs (3 independent groups of 2)
Nominal Voltage 24/48 VDC
Supported Sensor Types Platinum, Nickel, Copper RTDs
Diagnostics Open wire, short circuit, wiring errors, high/low alarms
Calibration Factory calibrated (no field calibration required)
Country of Origin United States

Connections / Interfaces

  • Genius Bus Interface: Connects directly to compatible Genius block modules and network communication cards.
  • Sensor Terminations: Secure screw terminal blocks for field-wiring connection of 2-wire, 3-wire, or 4-wire RTD inputs depending on configuration requirements.
  • Group Isolation: Electrically isolated input groups to minimize ground loops and common-mode noise interference.

Installation Guidelines

    Ensure all power to the Genius I/O block and associated terminal assemblies is disconnected before installation or removal.
    Mount the terminal assembly securely to its designated panel or backplate following standard industrial enclosure guidelines.
    Verify proper polarity and correct signal wiring for all RTD sensors prior to energizing the system.
    Confirm network termination and address switch settings on the associated block module for proper communication on the Genius bus.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the IC660TBA021?
The IC660TBA021 is a Genius terminal assembly designed to interface and process RTD temperature sensor inputs in General Electric industrial automation systems.
How many input channels does this terminal assembly support?
It supports a total of 6 RTD input circuits, which are separated into 3 independent groups of 2 circuits each.
What types of RTDs are compatible with the IC660TBA021?
The module natively supports platinum, nickel, and copper RTDs with automatic linearization for each type.
Does the IC660TBA021 require field calibration?
No, the unit is factory calibrated and does not require any manual field calibration during setup or operation.
What diagnostic features are included?
The module features automatic diagnostics that detect open wires, input shorts, wiring errors, external faults, and high/low input alarms.
Reviews

IC660TBA021

Stock & lead time on request

Call
1 of 1

General Electric IC660TBA021 Genius Terminal Assembly

Only 15 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IC660TBA021

  • Country of origin:United States

  • Product Type: Terminal Assembly

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 15.2 x 10.2 x 6.4 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The General Electric IC660TBA021 is a Genius I/O terminal assembly specifically engineered to support RTD (Resistance Temperature Detector) input blocks within industrial automation architectures. Operating on a 24/48 Volts DC nominal supply range, this terminal assembly provides reliable signal termination and interfacing capabilities for demanding process control and data acquisition environments. It is designed to seamlessly integrate with compatible Genius network interface modules, such as QBIM and PCIM, facilitating robust distributed I/O communications across the plant floor.

This terminal assembly features six individual RTD input circuits organized into three isolated, independent groups of two circuits each. It natively supports multiple sensor types—including platinum, nickel, and copper RTDs—and performs internal linearization based on the selected sensor profile. Temperature data is processed and reported directly to the system CPU in engineering units, delivering high-resolution feedback in tenths of degrees Celsius or Fahrenheit, tenths of ohms, or raw counts.

Engineered for high reliability and ease of maintenance, the IC660TBA021 includes factory calibration, eliminating the need for periodic field calibration procedures. The unit incorporates comprehensive built-in diagnostic capabilities that actively monitor for open wires, input shorts, high and low input alarms, wiring errors, and external faults, ensuring fast troubleshooting and maximum system uptime.

Features

  • Six RTD input circuits divided into three independent, isolated groups of two
  • Compatible with 24/48 Volts DC input power and signal ranges
  • Native support for platinum, nickel, and copper RTDs with automatic linearization
  • Factory-calibrated design requiring no manual adjustments or field calibration
  • Advanced onboard diagnostics for open wires, short circuits, wiring errors, and high/low alarms
  • Designed for seamless integration with Genius network interface modules including QBIM and PCIM

Applications

  • Distributed temperature monitoring and data acquisition
  • Process control systems in chemical and petrochemical plants
  • Power generation and turbine monitoring
  • Manufacturing automation and environmental testing chambers

Technical Specifications

Parameter Specification
Manufacturer General Electric
Catalog Number / SKU IC660TBA021
Product Type Genius Terminal Assembly
Series Genius I/O
Input Channels 6 RTD inputs (3 independent groups of 2)
Nominal Voltage 24/48 VDC
Supported Sensor Types Platinum, Nickel, Copper RTDs
Diagnostics Open wire, short circuit, wiring errors, high/low alarms
Calibration Factory calibrated (no field calibration required)
Country of Origin United States

Connections / Interfaces

  • Genius Bus Interface: Connects directly to compatible Genius block modules and network communication cards.
  • Sensor Terminations: Secure screw terminal blocks for field-wiring connection of 2-wire, 3-wire, or 4-wire RTD inputs depending on configuration requirements.
  • Group Isolation: Electrically isolated input groups to minimize ground loops and common-mode noise interference.

Installation Guidelines

    Ensure all power to the Genius I/O block and associated terminal assemblies is disconnected before installation or removal.
    Mount the terminal assembly securely to its designated panel or backplate following standard industrial enclosure guidelines.
    Verify proper polarity and correct signal wiring for all RTD sensors prior to energizing the system.
    Confirm network termination and address switch settings on the associated block module for proper communication on the Genius bus.
Loading product navigation…

What is the primary function of the IC660TBA021?

The IC660TBA021 is a Genius terminal assembly designed to interface and process RTD temperature sensor inputs in General Electric industrial automation systems.

How many input channels does this terminal assembly support?

It supports a total of 6 RTD input circuits, which are separated into 3 independent groups of 2 circuits each.

What types of RTDs are compatible with the IC660TBA021?

The module natively supports platinum, nickel, and copper RTDs with automatic linearization for each type.

Does the IC660TBA021 require field calibration?

No, the unit is factory calibrated and does not require any manual field calibration during setup or operation.

What diagnostic features are included?

The module features automatic diagnostics that detect open wires, input shorts, wiring errors, external faults, and high/low input alarms.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...

Commissioning a Linear Axis Without Hiding Mechanical Faults

A linear axis should be proven mechanically before aggressive tuning begins. This commissioning workflow covers scaling, direction, limits, homing, STO, low-speed tests, and evidence-based tuning for...

Interposing Relays: Isolation, Load Matching, and Diagnostics

Interposing relays protect PLC and DCS interfaces by separating voltage domains, matching output capacity to field loads, and making faults easier to isolate. This guide explains selection,...

Filtering Noisy PLC Signals Without Hiding Real Faults

Input filtering can stabilize PLC data, but excessive smoothing delays alarms and masks process changes. Learn how to diagnose noise, select hardware or software filters, and validate response time.

SCR or PWM? Choosing a Drive for Brushed DC Motors

SCR and PWM drives regulate brushed DC motors differently. Compare current ripple, low-speed torque, field control, feedback, reversing, braking energy, electromagnetic effects, and retrofit risks...