Description

The General Electric IC693MDL660 is a high-density 24-volt DC input module designed for the Series 90-30 programmable logic controller (PLC) platform. This module provides 32 discrete input points arranged in four isolated groups of eight inputs, offering efficient space utilization and high-density signal processing for industrial automation systems. It features a removable terminal block design that allows direct field device wiring without requiring intermediate transition bases and cables.

Engineered for reliable performance in demanding control environments, the IC693MDL660 supports selectable input filter times from 0.5 to 100 milliseconds to help suppress electrical noise. Configuration of this module requires Proficy Machine Edition Version 5.00 Service Pack 2 Logic Developer-PLC or later.

Features

  • 32 discrete input points per module, organized into four isolated groups of eight
  • Rated input voltage of 24 VDC with an input voltage range of 0 to 30 VDC
  • Selectable input filter times ranging from 0.5 to 100 ms for flexible noise rejection
  • Optical isolation rated at 250 VAC continuous and 1,500 VAC for one minute (field to backplane and group to group)
  • Removable terminal block compatibility (Box-style IC694TBB032 and spring clamp IC694TBS032 available separately)
  • Compatible with Series 90-30 baseplates and PACSystems RX3i modular systems using Series 90-30 I/O

Applications

  • Discrete manufacturing and assembly lines
  • Process control and monitoring systems
  • Machine automation requiring high-density digital signal acquisition
  • Conveyor and material handling control panels
  • Water and wastewater treatment facilities

Technical Specifications

Parameter Specification
Manufacturer General Electric
Catalog Number / Model IC693MDL660
Product Platform Series 90-30 PLC
Module Type High Density DC Input Module
Number of Inputs 32 inputs (4 isolated groups of 8 inputs)
Rated Voltage 24 VDC
Input Voltage Range 0 to 30 VDC
Input Current (Typical) 7.0 mA per point at rated voltage
On-State Voltage 11.5 to 30 VDC
Off-State Voltage 0 to 5 VDC
On-State Current (Max) 3.2 mA
Off-State Current (Max) 1.1 mA
Input Filter / Response Time 0.5 to 100 ms (selectable)
Backplane Power Consumption 300 mA from 5V bus (all inputs on)
Isolation (Field to Backplane) 250 VAC continuous; 1,500 VAC for 1 minute (optical)
Isolation (Group to Group) 250 VAC continuous; 1,500 VAC for 1 minute
Country of Origin United States

Connections / Interfaces

The module connects directly to a Series 90-30 baseplate slot. Field wiring is terminated externally using a removable terminal block (RTB), which must be ordered separately. Compatible terminal blocks include the IC694TBB032 (box-style) and IC694TBS032 (spring clamp).

Installation Guidelines

  • Always disconnect rack power before installing or removing the module from the Series 90-30 baseplate.
  • Ensure proper seating of the module into the baseplate connector and secure retention screws.
  • Use shielded cables for field wiring in high-electromagnetic-interference (EMI) environments to maintain signal integrity.
  • Verify configuration settings in Proficy Machine Edition match physical switch or software parameters before system startup.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the General Electric IC693MDL660 module and how many inputs does it feature?
The General Electric IC693MDL660 is a high-density 24-volt DC input module designed specifically for the Series 90-30 programmable logic controller platform. It provides a total of 32 discrete input points, which are conveniently arranged into four isolated groups of eight inputs each. This configuration ensures efficient space utilization and reliable digital signal acquisition in demanding industrial automation environments.
What are the electrical input characteristics and voltage ranges for this module?
The General Electric IC693MDL660 operates at a rated input voltage of 24 VDC with an allowable input voltage range spanning from 0 to 30 VDC. The on-state voltage threshold ranges from 11.5 to 30 VDC, while the off-state voltage is defined between 0 and 5 VDC. Additionally, the typical input current draws approximately 7.0 mA per point at the rated voltage.
How does the General Electric IC693MDL660 handle electrical noise and signal filtering?
The General Electric IC693MDL660 supports selectable input filter times ranging from 0.5 to 100 milliseconds to effectively suppress electrical noise in harsh industrial settings. Users can adjust these filter settings to optimize response times and maintain signal integrity. Proper configuration of these parameters helps prevent false triggering caused by electromagnetic interference.
What software is required to configure the General Electric IC693MDL660 input module?
Configuration of the General Electric IC693MDL660 requires Proficy Machine Edition Version 5.00 Service Pack 2 Logic Developer-PLC or later. This programming environment allows engineers to set up input filter times and map the 32 discrete input points correctly within the control system architecture. Technicians should always verify that software parameters match physical system setups prior to startup.
What isolation ratings and terminal block options are available for the General Electric IC693MDL660?
The General Electric IC693MDL660 features optical isolation rated at 250 VAC continuous and 1,500 VAC for one minute, protecting both field-to-backplane and group-to-group circuits. For field device wiring, the module utilizes a removable terminal block design that accommodates separately ordered accessories. Compatible options include the box-style IC694TBB032 and the spring clamp IC694TBS032 terminal blocks.
Reviews

IC693MDL660

Stock & lead time on request

Call
1 of 1

General Electric IC693MDL660 Series 90-30 24 Volt DC High Density Input Module

Only 20 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IC693MDL660

  • Country of origin:United States

  • Product Type: Input Module

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The General Electric IC693MDL660 is a high-density 24-volt DC input module designed for the Series 90-30 programmable logic controller (PLC) platform. This module provides 32 discrete input points arranged in four isolated groups of eight inputs, offering efficient space utilization and high-density signal processing for industrial automation systems. It features a removable terminal block design that allows direct field device wiring without requiring intermediate transition bases and cables.

Engineered for reliable performance in demanding control environments, the IC693MDL660 supports selectable input filter times from 0.5 to 100 milliseconds to help suppress electrical noise. Configuration of this module requires Proficy Machine Edition Version 5.00 Service Pack 2 Logic Developer-PLC or later.

Features

  • 32 discrete input points per module, organized into four isolated groups of eight
  • Rated input voltage of 24 VDC with an input voltage range of 0 to 30 VDC
  • Selectable input filter times ranging from 0.5 to 100 ms for flexible noise rejection
  • Optical isolation rated at 250 VAC continuous and 1,500 VAC for one minute (field to backplane and group to group)
  • Removable terminal block compatibility (Box-style IC694TBB032 and spring clamp IC694TBS032 available separately)
  • Compatible with Series 90-30 baseplates and PACSystems RX3i modular systems using Series 90-30 I/O

Applications

  • Discrete manufacturing and assembly lines
  • Process control and monitoring systems
  • Machine automation requiring high-density digital signal acquisition
  • Conveyor and material handling control panels
  • Water and wastewater treatment facilities

Technical Specifications

Parameter Specification
Manufacturer General Electric
Catalog Number / Model IC693MDL660
Product Platform Series 90-30 PLC
Module Type High Density DC Input Module
Number of Inputs 32 inputs (4 isolated groups of 8 inputs)
Rated Voltage 24 VDC
Input Voltage Range 0 to 30 VDC
Input Current (Typical) 7.0 mA per point at rated voltage
On-State Voltage 11.5 to 30 VDC
Off-State Voltage 0 to 5 VDC
On-State Current (Max) 3.2 mA
Off-State Current (Max) 1.1 mA
Input Filter / Response Time 0.5 to 100 ms (selectable)
Backplane Power Consumption 300 mA from 5V bus (all inputs on)
Isolation (Field to Backplane) 250 VAC continuous; 1,500 VAC for 1 minute (optical)
Isolation (Group to Group) 250 VAC continuous; 1,500 VAC for 1 minute
Country of Origin United States

Connections / Interfaces

The module connects directly to a Series 90-30 baseplate slot. Field wiring is terminated externally using a removable terminal block (RTB), which must be ordered separately. Compatible terminal blocks include the IC694TBB032 (box-style) and IC694TBS032 (spring clamp).

Installation Guidelines

  • Always disconnect rack power before installing or removing the module from the Series 90-30 baseplate.
  • Ensure proper seating of the module into the baseplate connector and secure retention screws.
  • Use shielded cables for field wiring in high-electromagnetic-interference (EMI) environments to maintain signal integrity.
  • Verify configuration settings in Proficy Machine Edition match physical switch or software parameters before system startup.
Loading product navigation…

What is the General Electric IC693MDL660 module and how many inputs does it feature?

The General Electric IC693MDL660 is a high-density 24-volt DC input module designed specifically for the Series 90-30 programmable logic controller platform. It provides a total of 32 discrete input points, which are conveniently arranged into four isolated groups of eight inputs each. This configuration ensures efficient space utilization and reliable digital signal acquisition in demanding industrial automation environments.

What are the electrical input characteristics and voltage ranges for this module?

The General Electric IC693MDL660 operates at a rated input voltage of 24 VDC with an allowable input voltage range spanning from 0 to 30 VDC. The on-state voltage threshold ranges from 11.5 to 30 VDC, while the off-state voltage is defined between 0 and 5 VDC. Additionally, the typical input current draws approximately 7.0 mA per point at the rated voltage.

How does the General Electric IC693MDL660 handle electrical noise and signal filtering?

The General Electric IC693MDL660 supports selectable input filter times ranging from 0.5 to 100 milliseconds to effectively suppress electrical noise in harsh industrial settings. Users can adjust these filter settings to optimize response times and maintain signal integrity. Proper configuration of these parameters helps prevent false triggering caused by electromagnetic interference.

What software is required to configure the General Electric IC693MDL660 input module?

Configuration of the General Electric IC693MDL660 requires Proficy Machine Edition Version 5.00 Service Pack 2 Logic Developer-PLC or later. This programming environment allows engineers to set up input filter times and map the 32 discrete input points correctly within the control system architecture. Technicians should always verify that software parameters match physical system setups prior to startup.

What isolation ratings and terminal block options are available for the General Electric IC693MDL660?

The General Electric IC693MDL660 features optical isolation rated at 250 VAC continuous and 1,500 VAC for one minute, protecting both field-to-backplane and group-to-group circuits. For field device wiring, the module utilizes a removable terminal block design that accommodates separately ordered accessories. Compatible options include the box-style IC694TBB032 and the spring clamp IC694TBS032 terminal blocks.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Commissioning a Linear Axis Without Hiding Mechanical Faults

A linear axis should be proven mechanically before aggressive tuning begins. This commissioning workflow covers scaling, direction, limits, homing, STO, low-speed tests, and evidence-based tuning for...

Interposing Relays: Isolation, Load Matching, and Diagnostics

Interposing relays protect PLC and DCS interfaces by separating voltage domains, matching output capacity to field loads, and making faults easier to isolate. This guide explains selection,...

Filtering Noisy PLC Signals Without Hiding Real Faults

Input filtering can stabilize PLC data, but excessive smoothing delays alarms and masks process changes. Learn how to diagnose noise, select hardware or software filters, and validate response time.

SCR or PWM? Choosing a Drive for Brushed DC Motors

SCR and PWM drives regulate brushed DC motors differently. Compare current ripple, low-speed torque, field control, feedback, reversing, braking energy, electromagnetic effects, and retrofit risks...

How Industrial Inverters Build AC From a DC Bus

Industrial inverters synthesize controlled AC from a DC bus, but reliable operation depends on PWM, motor control, cable effects, braking energy, thermal limits, protection, and commissioning across...

Robot Force Control: From Contact Detection to Stable Process

Robot force control adapts contact processes to real variation. This guide compares sensing methods and control modes, then explains tuning, safety boundaries, PLC integration, commissioning, and...