General Electric

General Electric IC698RMX016 PACSystems RX7i Redundancy Memory Xchange Module

SKU IC698RMX016

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric

  • Product No.: IC698RMX016

  • Country of origin:United States

  • Product Type: Redundancy Memory Module

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 23.3 x 16.0 x 4.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The General Electric IC698RMX016 is a PACSystems RX7i Redundancy Memory Xchange Module designed to function as a high-performance node within a reflective memory network or serve as a dedicated deterministic link connecting dual CPUs in a fault-tolerant redundant controller architecture. Engineered for high-speed data sharing, this module enables rapid, deterministic data synchronization across multiple automation systems and external computational devices without loading the main backplane or CPU communication resources.

Occupying a single slot within the PACSystems RX7i VME-based rack enclosure, the IC698RMX016 provides 16 megabytes of reflective memory capacity. It interfaces seamlessly with VMIC 5565 compatible reflective memory infrastructure, utilizing high-speed multimode fiber optic cabling to maintain low-latency data transmission over distances up to 300 meters. The module handles real-time memory updates independently, ensuring rapid switchover capabilities and continuous process synchronization in critical industrial control applications.

Features

  • 16 MB of high-speed reflective memory for real-time data exchange and node synchronization
  • Compatible with VMIC 5565 reflective memory standards and network topologies
  • Supports multimode fiber optic network connections up to 300 meters in length
  • Single-slot hardware footprint in PACSystems RX7i VME-based chassis racks
  • Deterministic data transfer independent of controller scan times for redundant system coordination

Applications

  • Hot-standby redundant CPU controller synchronization and failover management
  • High-speed deterministic data distribution across distributed PLC and SCADA nodes
  • Real-time process data logging and shared memory architectures in heavy industrial automation
  • Multi-controller integration requiring low-latency inter-processor communication

Technical Specifications

Parameter Specification
Brand General Electric
Product Series PACSystems RX7i
Catalog Number / SKU IC698RMX016
Module Type Redundancy Memory Xchange Module
Reflective Memory Capacity 16 MB
Backplane Voltage (5V) +5 VDC
Backplane Current Draw 1.8 A
Fiber Optic Interface Multimode fiber optic (compatible with VMIC 5565)
Maximum Cable Distance 300 meters
Slot Requirement 1 single RX7i rack slot
Operating Temperature 0 degC to 60 degC
Storage Temperature -40 degC to 85 degC
Country of Origin United States

Compliance and Certifications

  • UL Listed Industrial Control Equipment
  • CE compliant for applicable EU directives
  • FCC Part 15, Class A

FAQ

What is the primary function of the GE IC698RMX016 module?

The IC698RMX016 functions as a reflective memory node or a dedicated high-speed link connecting two CPUs in a redundant PACSystems RX7i control system, enabling deterministic data sharing and system synchronization.

How much memory does the IC698RMX016 provide?

The module provides 16 megabytes of high-speed reflective memory capacity for real-time data exchange across automation nodes.

What type of cabling is used for network connections?

It utilizes multimode fiber optic cables to connect with compatible VMIC 5565 reflective memory devices over distances up to 300 meters.

How many slots does this module occupy in an RX7i rack?

The IC698RMX016 occupies a single VME slot within a PACSystems RX7i rack enclosure.

What are the power requirements for the IC698RMX016?

The module operates on +5 VDC supplied by the RX7i rack backplane, with a current draw of approximately 1.8 A.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 12 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.