General Electric

General Electric IS200VRTDH1DAC Mark VI RTD Input Board

SKU IS200VRTDH1DAC

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric

  • Product No.: IS200VRTDH1DAC

  • Country of origin:United States

  • Product Type: RTD Input Board

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 300g

  • Dimensions: 2cm x 18.5cm x 26.1cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The IS200VRTDH1DAC operates as a high-density RTD input board developed by General Electric for deployment within the Mark VI Speedtronic turbine control platform. This assembly functions as a specialized temperature monitoring component that interfaces directly with external thermal resistance elements, supporting up to sixteen 3-wire RTD inputs through remote terminal boards. The IS200VRTDH1DAC routes field temperature measurements into the central VME rack architecture, facilitating integrated software linearization for precise closed-loop thermal regulation across gas and steam turbine configurations.

Features

  • Multi-Channel RTD Scalability: Built to handle sixteen independent 3-wire RTD inputs via remote terminal board interfacing.
  • Integrated Software Linearization: Provides automated correction profiles tailored for 10 Ohm copper, 100/200 Ohm platinum, or 120 Ohm nickel RTD sensing configurations.
  • Flexible Grounding Topology: Supports both grounded and ungrounded field sensor installation structures to suit localized system baselines.
  • Onboard Signal Isolation and Density: Populated with over 200 capacitors, several hundred resistors, and more than 200 integrated circuits including high-capacity Field Programmable Gate Arrays (FPGAs).
  • Conformal Surface Layering: Treated with a thin, protective conformal coating to preserve connection lines against continuous industrial environmental variables.

Applications

  • Mark VI Speedtronic gas and steam turbine thermal monitoring
  • High-density bearing and stator winding temperature measurement loops
  • VME rack configuration data acquisition systems

Technical Specifications

Item Description / Value
OEM General Electric
Series Mark VI Speedtronic
Part Number IS200VRTDH1DAC
Functional Acronym VRTD
Functional Description VME RTD Card
PCB Coating Conformal Coating
Functional Revision 1 D
RTD Inputs Capacity 16 channels (3-wire configuration)
Supported Sensor Types 10 Ohm copper, 100/200 Ohm platinum, 120 Ohm nickel
Status Monitoring Indicators Run (Green), Fail (Red), Status (Orange) LEDs
Physical Slot Profile Single-slot VME faceplate assembly

Installation Guidelines

  • VME Rack Fastening: Guide the card into its designated VME rack mounting assembly slot until the rear connectors mate with the backplane, then lock the metallic single-slot faceplate via the three structural fixing screws.
  • Signal Line Routing: Do not connect RTD field wires directly to this module. Route all external sensor loops to the companion RTD terminal board, and bridge the signals using the specified high-density cable assemblies.
  • Thermal Mitigation: Verify that the drilled cooling pathways surrounding targeted processing chips remain clear of obstructions during rack cabinet panel layout execution.

FAQ

Can field RTD sensors be wired directly onto the front faceplate of the device?

No, the sixteen 3-wire RTD inputs must be wired to an external RTD terminal board first and then linked to the VME rack via specialized interface cables.

What sensor materials are compatible with the software linearization feature on the device?

The integrated software linearization supports 10 Ohm copper, 100/200 Ohm platinum, and 120 Ohm nickel RTD configurations.

What is the function of the three colored LEDs on the single-slot faceplate?

The green, red, and orange LEDs provide immediate visual diagnostic status indicators for Run, Fail, and Status conditions respectively.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Dots
Country of origin
United States
Power source
DC Power

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.