Description

Designed for seamless integration within safety monitoring architectures, the Honeywell 05704-A-0133 serves as a highly configurable Fire Relay Interface Assembly. This module consists of an Expansion Relay Card fitted directly onto a Hex Relay Interface Card, providing comprehensive signaling capabilities for industrial monitoring systems. It acts as a rugged interface between logic controllers and field alarm devices, enabling flexible contact switching across diverse electrical environments.

The Honeywell 05704-A-0133 incorporates multiple relay contact styles to accommodate various load requirements. Users can configure individual relay actions to adapt to specific system demands, selecting between latching or non-latching states as well as normally energised or normally de-energised states. High-quality field terminals facilitate secure termination for heavy-duty field cabling, ensuring long-term operational integrity in critical safety configurations.

Features

  • Dual-card configuration consisting of an Expansion Relay Card mated to a Hex Relay Interface Card.
  • Comprehensive contact arrays featuring 10 x SPCO (Single Pole Change Over), 4 x SPST (Single Pole Single Throw), and 2 x DPCO (Double Pole Change Over) relays.
  • User-selectable relay configurations, supporting latching/non-latching and energised/de-energised logic.
  • High-capacity contact performance rated for up to 5A at 110V/250V AC and 5A at 32V DC under non-inductive loads.
  • Integrated field terminal blocks rated for conductors up to 2.5 mm² (14 AWG).

Applications

  • Industrial fire and gas detection networks.
  • Emergency shutdown (ESD) signaling and alarming systems.
  • Process safety interlocks and hazard mitigation controls.
  • Control room annunciator panel routing.

Technical Specifications

Manufacturer Honeywell
Part Number 05704-A-0133
Module Type Fire Relay Interface Assembly
Sub-Component Architecture Expansion Relay Card + Hex Relay Interface Card
Relay Contact Configurations 10 x SPCO, 4 x SPST, 2 x DPCO
Selectable Relay Operations Latching/Non-Latching, Energised/De-Energised
Relay Contact Rating (AC) 5A at 110V/250V AC (non-inductive)
Relay Contact Rating (DC) 5A at 32V DC (non-inductive)
Field Terminal Wire Size 2.5 mm² (14 AWG)
Power Consumption (Maximum) 7W
Power Consumption (Typical) 4W
Dimensions (L x W x H) 12.2 cm x 5.2 cm x 13.2 cm
Weight 0.51 kg

Installation Guidelines

  • Isolate all power sources before mounting or servicing the assembly.
  • Ensure the card assembly is correctly aligned and seated firmly into its designated rack slot or backplane interface.
  • Use suitable crimp ferrules on all field-wire terminations to ensure robust connectivity and prevent wire strand separation.
  • Separate low-voltage signal wiring from high-voltage relay switching lines to avoid inductive noise interference.

FAQ

What sub-modules comprise the Honeywell 05704-A-0133 assembly?

The Honeywell 05704-A-0133 consists of an Expansion Relay Card fitted directly to a Hex Relay Interface Card.

What are the configuration options for the relays on this module?

The relay operation modes are selectable. You can configure them to run as latching or non-latching, and as normally energised or normally de-energised.

What is the contact configuration breakdown for the 05704-A-0133?

The assembly features a total of 16 relays: 10 x SPCO (Single Pole Change Over), 4 x SPST (Single Pole Single Throw), and 2 x DPCO (Double Pole Change Over).

What size field wires can the terminals accommodate?

The field terminals on this assembly support wire cross-sections up to 2.5 mm² (14 AWG).

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

IC693DSM324 Replacement Checks: FSSB, Firmware and Follower Control

A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.

HIMA F3430 Replacement Checks: Contact Ratings and Safety Limits

A field-focused HIMA F3430 replacement guide covering relay contact ratings, DC load derating, fusing, F3330/F3331 differences, safety restrictions and commissioning records.

IC697PWR710 Replacement Checks: Load Budget and Dual-Rack Limits

A field-focused IC697PWR710 replacement guide covering 5 V load calculations, dual-rack limits, extension cables, input checks, protection behavior and hardware revision risks.

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.