Honeywell

Honeywell 8C-TAIXA1 51307125-175 Series 8 Non-Redundant Analog Input IOTA Assembly Coated

SKU 8C-TAIXA1

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: 8C-TAIXA1
  • Origin United States
  • Product Type: Analog Input IOTA
  • Payment: T/T, Western Union
  • Weight: 0.45 kg
  • Dimensions: 152 x 125 x 40 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The Honeywell 8C-TAIXA1 (Part Number 51307125-175) is a non-redundant Analog Input I/O Termination Assembly (IOTA) within the Experion PKS Series 8 C300 control system platform. Designed for compact panel layouts, this 6-inch termination assembly provides physical field wiring connection terminals and mounting carrier infrastructure for 16-channel analog input modules, specifically supporting HART-enabled analog input modules such as the 8C-PAIHA1.

The Honeywell 8C-TAIXA1 51307125-175 interfaces 4-20 mA current loops from 2-wire loop-powered or 4-wire self-powered transmitters directly into the C300 controller architecture. It features factory conformal coating to shield physical traces, terminal blocks, and passive components from industrial airborne contaminants, corrosive gases, and humidity.

Serving as the physical mounting foundation, the non-redundant IOTA assembly allows field wiring to remain permanently attached to screw terminals while facilitating seamless I/O Module Removal and Insertion Under Power (RIUP). This architecture minimizes downtime during maintenance and streamlines cabinet field wiring.

Features

  • Compact Form Factor: Measures 6 inches in width, saving space on panel DIN rails while providing termination points for up to 16 analog input channels.
  • Factory Conformal Coating: Conformal coating protects trace layouts, solder joints, and terminal interconnections against aggressive chemical environments and humidity.
  • Single-Module IOTA Carrier: Built for non-redundant control configurations, accommodating a single 16-channel Series 8 Analog Input module.
  • Direct Field Transmitter Interface: Connects 4-20 mA DC signals from 2-wire loop-powered and self-powered process instrumentation.
  • Online Maintenance Support: Enables Module Removal and Insertion Under Power (RIUP) without disconnecting field wiring or interrupting power to adjacent assemblies.
  • Integral Bus Interconnects: Provides internal routing for 24 VDC system distribution and high-speed communication buses to the C300 execution environment.

Applications

  • Experion PKS Series 8 Cabinet Integration: Serves as the physical termination base for non-redundant 16-channel analog input modules.
  • Process Instrumentation Wiring: Terminates field signals from pressure transmitters, temperature transmitters, flowmeters, and level sensors.
  • Hazardous & Corrosive Plant Enclosures: Deployed in process environments requiring conformal coated termination hardware to withstand harsh atmospheric conditions.
  • Continuous Control Strategies: Relays high-density analog loop measurements directly to C300 controllers for real-time monitoring and process logic.

Technical Specifications

General

Parameter Specification
Manufacturer Honeywell
Model Number 8C-TAIXA1
Part Number 51307125-175
Product Type Non-Redundant Analog Input I/O Termination Assembly (IOTA)
System Architecture Experion PKS Series 8 C300
Redundancy Non-Redundant (Single Module)
Surface Protection Factory Conformal Coated
Supported I/O Module 8C-PAIHA1 (Analog Input with HART, 16-Channel)

Electrical & Signal Properties

Parameter Specification
Channel Capacity 16 Channels
Input Signal Type Current (4-20 mA DC through 250 Ohm)
Field Device Support 2-wire (loop-powered) or self-powered transmitters
Operating Voltage Rating 24 VDC
Maximum Input Voltage Rating +/- 30 Volts (any input referenced to common, no damage)

Physical & Mechanical

Parameter Specification
Mounting Base Width 6 inches
Hot Swappability Supports Module Removal and Insertion Under Power (RIUP)
Field Termination Type Screw-type terminal block connections

Connections / Interfaces

Interface Function
Field Terminal Blocks Terminal strip connections for 16-channel 4-20 mA transmitter loops
I/O Module Socket Multi-pin backplane connector for mounting the 8C-PAIHA1 module
System Power Bus Internal 24 VDC bus routing for module power distribution

Installation Guidelines

  1. Ensure panel DC power supplies are isolated before mounting or wiring the IOTA assembly.
  2. Secure the 8C-TAIXA1 6-inch termination assembly onto standard panel enclosure DIN rail structures using appropriate end stops.
  3. Wire field transmitters to designated channel terminals according to 2-wire or self-powered device wiring diagrams.
  4. Verify field wiring polarity and ensure proper grounding/shielding practices are implemented across signal lines.
  5. Align the corresponding Series 8 I/O module (e.g., 8C-PAIHA1) with the socket headers on the 8C-TAIXA1 assembly.
  6. Press the module firmly into place until retaining mechanical latches click into place.
  7. Apply 24 VDC system power and verify power and channel status indicators on the mounted module.

Configuration / Commissioning / Replacement Guidelines

Configuration Guidelines

  • Assign physical channel numbers in Honeywell Control Builder to match the field terminal assignments on the 8C-TAIXA1 assembly.
  • Select correct input channel modes (4-20 mA current loop settings) within the Experion software environment.

Commissioning Recommendations

  • Perform loop checks by verifying current signals at the 8C-TAIXA1 field terminal screws with a calibrated process calibrator prior to system sign-off.
  • Ensure all field signal shield lines are ground-terminated at the dedicated cabinet ground bar and isolated from the IOTA base.

Replacement Recommendations

  • Module Removal and Insertion Under Power (RIUP) allows replacing the mounted I/O module without removing field wires from the 8C-TAIXA1 assembly.
  • If replacing the 8C-TAIXA1 termination base itself, turn off 24 VDC field power, disconnect field signal terminals, unlatch the mounted I/O module, and unmount the base from the DIN rail.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the function of the Honeywell 8C-TAIXA1 51307125-175 termination assembly?
The Honeywell 8C-TAIXA1 51307125-175 Series 8 non-redundant Analog Input IOTA serves as a 6-inch mounting base and field wiring connection point for 16-channel analog input modules like the 8C-PAIHA1 within Honeywell Experion PKS C300 DCS networks.
Which I/O module mounts onto the Honeywell 8C-TAIXA1 51307125-175 base?
The Honeywell 8C-TAIXA1 51307125-175 non-redundant IOTA is engineered specifically to host 16-channel Series 8 analog input modules, such as the 8C-PAIHA1 HART-enabled analog input module.
What is the key difference between 8C-TAIXA1 and 8C-TAIXB1 IOTA assemblies?
The Honeywell 8C-TAIXA1 51307125-175 is a 6-inch non-redundant single-module IOTA base, whereas the 8C-TAIXB1 is a 12-inch redundant IOTA assembly designed to hold two redundant analog input modules.
Does the Honeywell 8C-TAIXA1 51307125-175 support hot swapping of mounted modules?
The Honeywell 8C-TAIXA1 51307125-175 supports Module Removal and Insertion Under Power (RIUP), enabling technicians to replace the attached analog input module without disconnecting field wiring or shutting down power to the assembly.
Reviews

8C-TAIXA1

Stock & lead time on request

Call
1 of 3

Honeywell 8C-TAIXA1 51307125-175 Series 8 Non-Redundant Analog Input IOTA Assembly Coated

Only 10 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 8C-TAIXA1

  • Country of origin:United States

  • Product Type: Analog Input IOTA

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 152 x 125 x 40 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Honeywell 8C-TAIXA1 (Part Number 51307125-175) is a non-redundant Analog Input I/O Termination Assembly (IOTA) within the Experion PKS Series 8 C300 control system platform. Designed for compact panel layouts, this 6-inch termination assembly provides physical field wiring connection terminals and mounting carrier infrastructure for 16-channel analog input modules, specifically supporting HART-enabled analog input modules such as the 8C-PAIHA1.

The Honeywell 8C-TAIXA1 51307125-175 interfaces 4-20 mA current loops from 2-wire loop-powered or 4-wire self-powered transmitters directly into the C300 controller architecture. It features factory conformal coating to shield physical traces, terminal blocks, and passive components from industrial airborne contaminants, corrosive gases, and humidity.

Serving as the physical mounting foundation, the non-redundant IOTA assembly allows field wiring to remain permanently attached to screw terminals while facilitating seamless I/O Module Removal and Insertion Under Power (RIUP). This architecture minimizes downtime during maintenance and streamlines cabinet field wiring.

Features

  • Compact Form Factor: Measures 6 inches in width, saving space on panel DIN rails while providing termination points for up to 16 analog input channels.
  • Factory Conformal Coating: Conformal coating protects trace layouts, solder joints, and terminal interconnections against aggressive chemical environments and humidity.
  • Single-Module IOTA Carrier: Built for non-redundant control configurations, accommodating a single 16-channel Series 8 Analog Input module.
  • Direct Field Transmitter Interface: Connects 4-20 mA DC signals from 2-wire loop-powered and self-powered process instrumentation.
  • Online Maintenance Support: Enables Module Removal and Insertion Under Power (RIUP) without disconnecting field wiring or interrupting power to adjacent assemblies.
  • Integral Bus Interconnects: Provides internal routing for 24 VDC system distribution and high-speed communication buses to the C300 execution environment.

Applications

  • Experion PKS Series 8 Cabinet Integration: Serves as the physical termination base for non-redundant 16-channel analog input modules.
  • Process Instrumentation Wiring: Terminates field signals from pressure transmitters, temperature transmitters, flowmeters, and level sensors.
  • Hazardous & Corrosive Plant Enclosures: Deployed in process environments requiring conformal coated termination hardware to withstand harsh atmospheric conditions.
  • Continuous Control Strategies: Relays high-density analog loop measurements directly to C300 controllers for real-time monitoring and process logic.

Technical Specifications

General

Parameter Specification
Manufacturer Honeywell
Model Number 8C-TAIXA1
Part Number 51307125-175
Product Type Non-Redundant Analog Input I/O Termination Assembly (IOTA)
System Architecture Experion PKS Series 8 C300
Redundancy Non-Redundant (Single Module)
Surface Protection Factory Conformal Coated
Supported I/O Module 8C-PAIHA1 (Analog Input with HART, 16-Channel)

Electrical & Signal Properties

Parameter Specification
Channel Capacity 16 Channels
Input Signal Type Current (4-20 mA DC through 250 Ohm)
Field Device Support 2-wire (loop-powered) or self-powered transmitters
Operating Voltage Rating 24 VDC
Maximum Input Voltage Rating +/- 30 Volts (any input referenced to common, no damage)

Physical & Mechanical

Parameter Specification
Mounting Base Width 6 inches
Hot Swappability Supports Module Removal and Insertion Under Power (RIUP)
Field Termination Type Screw-type terminal block connections

Connections / Interfaces

Interface Function
Field Terminal Blocks Terminal strip connections for 16-channel 4-20 mA transmitter loops
I/O Module Socket Multi-pin backplane connector for mounting the 8C-PAIHA1 module
System Power Bus Internal 24 VDC bus routing for module power distribution

Installation Guidelines

  1. Ensure panel DC power supplies are isolated before mounting or wiring the IOTA assembly.
  2. Secure the 8C-TAIXA1 6-inch termination assembly onto standard panel enclosure DIN rail structures using appropriate end stops.
  3. Wire field transmitters to designated channel terminals according to 2-wire or self-powered device wiring diagrams.
  4. Verify field wiring polarity and ensure proper grounding/shielding practices are implemented across signal lines.
  5. Align the corresponding Series 8 I/O module (e.g., 8C-PAIHA1) with the socket headers on the 8C-TAIXA1 assembly.
  6. Press the module firmly into place until retaining mechanical latches click into place.
  7. Apply 24 VDC system power and verify power and channel status indicators on the mounted module.

Configuration / Commissioning / Replacement Guidelines

Configuration Guidelines

  • Assign physical channel numbers in Honeywell Control Builder to match the field terminal assignments on the 8C-TAIXA1 assembly.
  • Select correct input channel modes (4-20 mA current loop settings) within the Experion software environment.

Commissioning Recommendations

  • Perform loop checks by verifying current signals at the 8C-TAIXA1 field terminal screws with a calibrated process calibrator prior to system sign-off.
  • Ensure all field signal shield lines are ground-terminated at the dedicated cabinet ground bar and isolated from the IOTA base.

Replacement Recommendations

  • Module Removal and Insertion Under Power (RIUP) allows replacing the mounted I/O module without removing field wires from the 8C-TAIXA1 assembly.
  • If replacing the 8C-TAIXA1 termination base itself, turn off 24 VDC field power, disconnect field signal terminals, unlatch the mounted I/O module, and unmount the base from the DIN rail.
Loading product navigation…

What is the function of the Honeywell 8C-TAIXA1 51307125-175 termination assembly?

The Honeywell 8C-TAIXA1 51307125-175 Series 8 non-redundant Analog Input IOTA serves as a 6-inch mounting base and field wiring connection point for 16-channel analog input modules like the 8C-PAIHA1 within Honeywell Experion PKS C300 DCS networks.

Which I/O module mounts onto the Honeywell 8C-TAIXA1 51307125-175 base?

The Honeywell 8C-TAIXA1 51307125-175 non-redundant IOTA is engineered specifically to host 16-channel Series 8 analog input modules, such as the 8C-PAIHA1 HART-enabled analog input module.

What is the key difference between 8C-TAIXA1 and 8C-TAIXB1 IOTA assemblies?

The Honeywell 8C-TAIXA1 51307125-175 is a 6-inch non-redundant single-module IOTA base, whereas the 8C-TAIXB1 is a 12-inch redundant IOTA assembly designed to hold two redundant analog input modules.

Does the Honeywell 8C-TAIXA1 51307125-175 support hot swapping of mounted modules?

The Honeywell 8C-TAIXA1 51307125-175 supports Module Removal and Insertion Under Power (RIUP), enabling technicians to replace the attached analog input module without disconnecting field wiring or shutting down power to the assembly.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...