Honeywell

Honeywell 2MLT-DMMA MasterLogic-200 Dust Protection Module

SKU 2MLT-DMMA

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: 2MLT-DMMA

  • Country of origin:United States

  • Product Type: Dust Protection Module

  • Payment: T/T, Western Union

  • Weight: 100g

  • Dimensions: 110 mm x 95 mm x 55 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

The Honeywell 2MLT-DMMA is a dust protection module designed for installation into unused slots on MasterLogic-200 PLC base units. It serves as a protective cover to shield internal connectors and backplane circuitry from environmental contaminants such as airborne dust and dirt, maintaining system integrity in industrial operating environments.

Features

  • Protective enclosure designed for unused I/O or option module slots on MasterLogic-200 bases.
  • Helps prevent dust and particulate accumulation on backplane connectors.
  • Maintains a clean enclosure structure in harsh industrial atmospheres.

Applications

  • Slot protection for unused base locations in MasterLogic-200 PLC control cabinets.
  • Shielding open backplane interfaces against dust during system expansion or staging.

Ordering Information

Model Description Remarks
2MLT-DMMA

Dust protection module for unused slot

MasterLogic-200 option

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model 2MLT-DMMA
Product Type Dust protection module for unused slot
System Series MasterLogic-200
Operating Temperature 0 to 55 degC
Storage Temperature -25 to +70 degC
Ambient Humidity 5 to 95%RH (Non-condensing)
Storage Humidity 5 to 95%RH (Non-condensing)
Atmosphere Free from corrosive gases and excessive dust
Altitude Less than 2,000m
Pollution Degree Less than 2
Cooling Method Air-cooling

Installation Guidelines

  • Insert the module securely into any empty module slot on a MasterLogic-200 base unit to cover exposed connector contacts.
  • Ensure the cabinet environment remains free from corrosive gases and excessive dust accumulation.

Compliance and Certifications

Certification / Standard Detail
UL UL 508 Industrial Control Equipment
CE EN 50081-2, Emissions, Industrial
CE EN 50082-2, Immunity, Industrial

FAQ

What is the Honeywell 2MLT-DMMA used for?

The Honeywell 2MLT-DMMA is a dust protection module used to cover and protect unused slots on MasterLogic-200 PLC bases.

Which system series is the 2MLT-DMMA compatible with?

The 2MLT-DMMA module is compatible with the Honeywell MasterLogic-200 PLC system.

What is the operating temperature range for the device?

The operating temperature range for the module is 0 to 55 degC.

What certifications apply to the MasterLogic-200 system components?

The system components carry UL 508 and CE industrial standards compliance.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell 2MLT-DMMA MasterLogic-200 Dust Protection Module

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.

PLC I/O Modules: Wiring, Load, and Isolation Checks

A field checklist for matching PLC digital and analog I/O to sensors, loads, commons, isolation groups, filters, and replacement settings.