Honeywell

Honeywell 8C-TAOX61 51306981-175 Series 8 Analog Output Module

SKU 8C-TAOX61 51306981-175

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: 8C-TAOX61 51306981-175

  • Country of origin:United States

  • Product Type: Analog Output Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 350g

  • Dimensions: 15.0 x 10.0 x 5.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Honeywell 8C-TAOX61 (model 51306981-175) is a high-density analog output module engineered for the Experion PKS Series 8 distributed control architecture. This module interfaces control system logic directly with plant-floor actuators, control valves, and positioners by converting digital controller values into precise analog current or voltage signals. It mounts onto dedicated Series 8 I/O carriers and communicates internally via the system's high-speed I/O link.

Designed for continuous process control environments, the 8C-TAOX61 supports multi-channel output deployment to streamline panel layout and reduce footprint within marshalling cabinets. It incorporates channel-to-channel isolation and diagnostic monitoring to detect open loops, short circuits, and field-power anomalies, feeding status alerts back to the Experion C300 controller or redundant controller architecture.

Features

  • Native component of the Honeywell Experion PKS Series 8 I/O platform
  • Supports multi-channel analog output configurations for precision control devices
  • Provides optical isolation between field outputs and system logic circuitry
  • On-board diagnostic reporting for open-circuit and short-circuit fault detection
  • Hot-swappable module design permits replacement without shutting down the entire node

Applications

  • Proportional control valve positioning in refining and chemical units
  • Speed reference generation for variable frequency drives
  • Analog setpoint transmission to secondary instrumentation and recorders
  • Actuator control loops within continuous process manufacturing

Technical Specifications

Parameter Specification
Brand Honeywell
Series Experion PKS Series 8
Catalog Number / Model 8C-TAOX61
Part Number 51306981-175
Module Type Analog Output Module
Operating Temperature 0 degC to 60 degC
Storage Temperature -40 degC to 85 degC
Relative Humidity 5% to 95% non-condensing
Country of Origin United States

Compliance and Certifications

  • CE compliant for European Union directives
  • UL listed for industrial control equipment
  • CSA certified for hazardous locations Class 1, Division 2 (when installed per applicable guidelines)

FAQ

What control system is the Honeywell 8C-TAOX61 designed for?

The 8C-TAOX61 is built specifically for the Honeywell Experion PKS Series 8 distributed control system platform.

Is the 8C-TAOX61 module hot-swappable?

Yes, Series 8 I/O modules support hot-swapping, allowing replacement on an active carrier without powering down the entire node.

What is the part number associated with model 8C-TAOX61?

The corresponding Honeywell part number is 51306981-175.

What diagnostics does the output module provide?

The module monitors loop continuity and reports faults such as open circuits, short circuits, and channel-level errors back to the Experion controller.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 3 item(s) left in stock
Quantity
View full details
Loading product navigation…

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...

Commissioning a Linear Axis Without Hiding Mechanical Faults

A linear axis should be proven mechanically before aggressive tuning begins. This commissioning workflow covers scaling, direction, limits, homing, STO, low-speed tests, and evidence-based tuning for...

Interposing Relays: Isolation, Load Matching, and Diagnostics

Interposing relays protect PLC and DCS interfaces by separating voltage domains, matching output capacity to field loads, and making faults easier to isolate. This guide explains selection,...