Honeywell

Honeywell 10106/2/1 Fail-Safe Line-Monitored Digital Input Module

SKU 10106/2/1

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: 10106/2/1

  • Country of origin:United States

  • Product Type: Fail-Safe Digital Input Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 400g

  • Dimensions: 2.5 x 14 x 19.1 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Honeywell 10106/2/1 is a 16-channel fail-safe digital input module for Honeywell FSC systems. It is designed for 24/48 VDC NAMUR field inputs with line monitoring and earth-fault supervision.

The module uses NAMUR input characteristics and monitors field circuits rather than only reading ON/OFF states. This makes the 10106/2/1 suitable where input wiring faults must be distinguished from normal process status. Honeywell FSC documentation identifies it as a fail-safe line-monitored digital input module with earth fault monitor.

Features

  • 16 digital input channels
  • Fail-safe input processing
  • NAMUR input interface
  • 24/48 VDC field input application
  • Line-monitored input circuits
  • Earth-fault monitoring
  • 1.4 to 1.9 mA switching level
  • 0.2 mA hysteresis
  • Maximum 50 Ohm field-wire resistance
  • Short-circuit-protected 8 V loop supply

Applications

  • Safety-related digital input acquisition
  • NAMUR sensor and contact monitoring
  • Field wiring supervision
  • ESD and interlock input processing
  • Honeywell FSC I/O replacement

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Product Number 10106/2/1
Product Type Fail-Safe Line-Monitored Digital Input Module
System Honeywell FSC
Number of Channels 16
Input Type NAMUR, DIN 19234
Field Input Application 24/48 VDC
Switch Level 1.4 to 1.9 mA
Hysteresis 0.2 mA +/-0.05 mA
Field Wire Resistance 50 Ohm maximum
8 V Loop Supply 7.9 to 8.7 V
Loop Supply Current 170 mA, short-circuit protected
Dimensions 2.5 x 14 x 19.1 cm

Power Requirements

Supply Current
5 VDC 160 mA
24 VDC 110 mA

Earth-Fault Monitoring

Parameter Specification
Earth Connection Monitor 1
Input Resistance Typically 0.5 MOhm
Input Resistance Range -40 V < U < +40 V
Test Current Typically 0.5 mA
Output Voltage Typically 0.5 VDC
Maximum Field Fault Voltage 250 VAC

Replacement Notes

  • Match the complete 10106/2/1 model number.
  • Confirm the existing field circuits use the NAMUR configuration.
  • Preserve channel wiring and line-monitoring arrangements during replacement.
  • Modules with suffix code 22100 have a documented restriction when used with 10106/A/2 converter modules.

FAQ

What is the Honeywell 10106/2/1 used for?

The Honeywell 10106/2/1 is a 16-channel fail-safe digital input module for NAMUR field signals in Honeywell FSC systems, with line and earth-fault monitoring.

How many inputs does the Honeywell 10106/2/1 provide?

The Honeywell 10106/2/1 provides 16 digital input channels using NAMUR input characteristics for monitored field circuits.

Does the Honeywell 10106/2/1 monitor field wiring faults?

The Honeywell 10106/2/1 provides line monitoring and an earth-fault monitor, allowing the FSC system to supervise field wiring in addition to reading digital input states.

What should be checked before replacing a Honeywell 10106/2/1?

The Honeywell 10106/2/1 replacement should match the exact module number, NAMUR field configuration, channel wiring, line-monitoring arrangement, and any suffix-specific hardware restrictions.

View all FAQs →

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.