1 of 3

Honeywell 51109693-100B Universal Control Network (UCN) 4-Port Drop Cable Tap Ground Module

Honeywell 51109693-100B Universal Control Network (UCN) 4-Port Drop Cable Tap Ground Module

Only 6 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 51109693-100B

  • Country of origin:United States

  • Product Type: Universal Control Network Tap Blocks

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 240g

  • Dimensions: 12.0 cm x 9.8 cm x 4.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Honeywell 51109693-100B is a specialized network interface components designed for the Universal Control Network (UCN) within legacy TotalPlant Solution (TPS) and TDC 3000 Distributed Control Systems (DCS). This module serves as a ruggedized 4-port drop cable tap ground block, facilitating secure coax interface coupling and precise grounding infrastructure for critical high-speed control data lines.

Engineered strictly for harsh industrial control environments, the 51109693-100B establishes robust branch connections from the primary UCN trunk line to individual nodes such as High-Performance Process Managers (HPM), Network Interface Modules (NIM), or Advanced Process Managers (APM). By providing high-integrity shielding terminations and static discharge paths, the module actively prevents common-mode noise propagation, ground-loop disruptions, and signal attenuation along the network segment. Its industrial-grade passive architecture ensures uninterrupted physical layer operations and uniform impedance matching necessary for continuous multi-node industrial process synchronization.

Features

  • Features an integrated 4-port drop cable connection infrastructure enabling dual or multi-node transceiver drops from a localized point.
  • Incorporates a dedicated low-resistance grounding bus bar interface to drain induced EMI/RFI interference away from coax cores.
  • Maintains strict physical layer attenuation parameters to ensure signal integrity across extended TDC 3000 network topologies.
  • Designed with heavy-duty cast aluminum or specialized shielding material to shield inner high-frequency junctions from ambient industrial noise.
  • Employs tight-tolerance BNC or specialized coax termination mechanisms minimizing insertion losses and reflection coefficients.

Applications

  • Distributed Control System (DCS) physical layer installation in petrochemical plants and oil refineries running Honeywell TDC 3000 / TPS platforms.
  • Specialized grounding and drop distribution for high-reliability communications between HPM subsystems and Network Interface Modules (NIM).
  • Power generation utility networks requiring isolated and noise-immune fieldbus topologies across long physical distances.
  • Pulp, paper, and heavy manufacturing processing lines utilizing legacy coaxial-based corporate process control infrastructures.

Technical Specifications

Parameter Specifications
Manufacturer Honeywell
Model Number 51109693-100B
Alternative Part Identifier 51201395-100 Kit Reference
Device Type Universal Control Network (UCN) Drop Cable Tap Ground Block
Port Configuration 4-Port Distribution / Drop Capacity
Network Interface Coaxial Cable Trunk Line Drop Tap
Country of Origin USA
Physical Dimensions (H x W x D) 12.0 cm x 9.8 cm x 4.0 cm
Net Weight 0.24 kg
Housing Construction High-density shielded industrial enclosure

Connections/Interfaces

Connector Pin Function
Trunk In Primary Coaxial UCN Cable Input Segment
Trunk Out Continuous Primary Coaxial UCN Cable Output Continuation
Drop Port 1 Node Branch Drop Line Connection 1
Drop Port 2 Node Branch Drop Line Connection 2
Drop Port 3 Node Branch Drop Line Connection 3
Drop Port 4 Node Branch Drop Line Connection 4
GND Stud Main Earth Reference Low-Impedance Grounding Connection

Installation Guidelines

  • Grounding Requirements: Secure the main external ground lug directly to the local instrumentation clean ground bus bar via a low-impedance braided copper strap. Avoid chaining ground paths across multiple separate mechanical frames.
  • Shielding and EMI Isolation: Ensure complete coaxial outer shield continuity through the terminal clamps to prevent RF leakage and high-frequency common-mode industrial noise entry.
  • Cable Routing Precautions: Route incoming and outgoing trunk cables through dedicated low-voltage data conduits, maintaining a minimum 300mm clearance from high-voltage AC supply lines or variable frequency drive outputs.
  • Drop Cable Bend Radius: Adhere strictly to the OEM coax specifications regarding minimum bend radii during installation inside local field marshaling panels to prevent structural dielectric deformation.

FAQ

  • What is the core function of the 51109693-100B within a Honeywell DCS network?

    The module acts as a localized 4-port drop junction and signal grounding block on the Universal Control Network, linking primary coax trunks to node transceivers without degrading impedance characteristics.

  • Does this unit require external active power loops to run?

    No, this is an entirely passive mechanical and electrical interface unit designed for signal division, impedance maintenance, and grounding mitigation across coaxial lines.

  • Can unused drop ports be left open during active system runtime?

    No, all unused drop terminals on active network lines should be fitted with compatible high-frequency impedance terminators to avoid signal reflections and potential frame corruption errors.

  • What mounting orientation is ideal for maximizing environmental resilience?

    The module should be mounted inside a dust-proof NEMA/IP-rated control enclosure, preferably with the drop connectors facing downwards to avoid moisture ingress or debris accumulation within the female barrels.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White Silver
Country of origin
United States

Recently Viewed Products

Technical knowledge

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...

Single-Axis Motion Control Setup with CMZ Servo Drives

This tutorial explores the commissioning of a single-axis servo motion system using a CMZ SBD drive, covering hardware setup, axis scaling, homing configuration, and safe motion verification for...

Mitsubishi FX PLC Integration With FR-D700 VFD and HMI Control

This tutorial explains how Mitsubishi FX PLCs integrate with FR-D700 VFDs and HMI panels for forward/reverse motor control. It covers wiring logic, parameter configuration, ladder programming, and...