Description
Designed for high-integrity safety and control applications, the FC-QPP-0002 serves as a core processing component within proprietary Honeywell industrial automation systems. This quad processor module provides robust computational execution and diagnostics, enabling fault-tolerant operations in demanding environments. The module manages critical safety logic execution, interfacing with dedicated backplane architectures to maintain continuous, high-availability monitoring of process parameters.
Features
- Quad-processing architecture designed for high system availability and fault tolerance.
- Continuous short-circuit protection on field output channels.
- Integrated reverse polarity protection on low-level inputs.
- Extensive diagnostic coverage monitoring internal module temperatures and power supply integrity.
- Passive cooling design optimized for standard rack mounting.
Applications
- Emergency Shutdown Systems (ESD)
- Fire and Gas Detection Systems (F&G)
- Burner Management Systems (BMS)
- Critical process control applications in chemical, oil, and gas industries
Technical Specifications
| Manufacturer |
Honeywell |
| Part Number/Model |
FC-QPP-0002 |
| Module Type |
Quad Processor |
| Operating Temperature (Outside) |
-5 degC to +70 degC (+23 degF to +158 degF) |
| Operating Temperature (Inside) |
-5 degC to +70 degC (+23 degF to +158 degF) |
| Storage Temperature |
-40 degC to +85 degC (-40 degF to +185 degF) |
| Relative Humidity |
10% to 95% (non-condensing) |
| 24 V Supply Voltage |
24 Vdc (-15% to +30%) |
| 24 V Supply Current |
max. 25 mA |
| 5 V Supply Voltage |
5 Vdc (+/- 5%) |
| 5 V Supply Current |
max. 1.2 A |
| Output Supply Voltage |
15 to 31 Vdc |
| Output Resistance |
approx. 1.1 kOhm |
| Short Circuit Protection |
Continuous |
| Input Voltage (High) |
15 to 32 Vdc |
| Input Voltage (Low) |
< 4 V (reverse polarity protected) |
| Input Current |
approx. 8 mA at 24 Vdc |
| Output Current |
750 mA per output |
| Dimensions (H x W x D) |
176 x 88.5 x 212 mm |
| Weight |
1.3 kg |
Installation Guidelines
- Verify that the system chassis or rack is completely powered down before inserting or removing the processor module.
- Ensure adequate clearance around the module assembly to allow for natural convection cooling, keeping ambient temperatures within the specified limits.
- Properly ground the system rack in accordance with local electrical codes and industrial standards to minimize electromagnetic interference.
- Check all field wiring connections for reverse polarity and voltage compatibility before commissioning.
Compliance and Certifications