Honeywell

Honeywell 8C-TAOX51 51306983-175 PlantCruise Series 8 Analog Output IOTA

SKU 8C-TAOX51 51306983-175

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: 8C-TAOX51 51306983-175

  • Country of origin:United States

  • Product Type: Analog Output IOTA

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 152 mm x 120 mm x 85 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Honeywell 8C-TAOX51 (part number 51306983-175) is a conformal-coated, non-redundant 6-inch Input Output Termination Assembly (IOTA) designed for PlantCruise Series 8 process control systems. It combines field wiring termination and the Analog Output Input Output Module (IOM) into a single compact area, eliminating the need for a separate electronics chassis. Operating directly from a 24 VDC carrier power bus, the unit delivers non-incendive field power distribution across 16 channels without requiring external marshalling or inline fusing. The assembly features two-level detachable screw terminals, integrated signal conditioning, and on-board connection to the I/O Link for standard 4-20 mA and HART-capable analog output operations.

Features

  • Combines field terminations and I/O module mounting in a single unit, eliminating external chassis requirements.
  • Equipped with two-level detachable terminal blocks for simple field wiring installation and maintenance.
  • Supplies non-incendive field power directly through an integrated 24 VDC bus connection on the carrier.
  • Conformal coating protection (8C designator) against humidity, dust, chemicals, and temperature extremes.
  • Vertical mounting orientation and tilted physical layout engineered for cabinet space efficiency and heat management.
  • Short-circuit protected output circuits that eliminate inline fusing needs.

Applications

  • Field wiring termination and power distribution for 16-channel 4-20 mA analog output devices.
  • Interfacing actuators, positioners, and recording instruments in Honeywell PlantCruise by Experion architectures.
  • Class 1, Division 2 hazardous area deployments requiring non-incendive field power conditioning.

Ordering Information

Model Description Size Redundancy Support
8C-TAOX51 AO IOTA, Coated 6 in (152 mm) Non-Redundant
8C-TAOX61 AO IOTA, Coated 12 in (304 mm) Redundant
8U-TAOX51 AO IOTA, Uncoated 6 in (152 mm) Non-Redundant
8U-TAOX61 AO IOTA, Uncoated 12 in (304 mm) Redundant

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model 8C-TAOX51
Part Number 51306983-175
Product Type Input Output Termination Assembly (IOTA)
System Compatibility PlantCruise Series 8
Physical Coating Conformal Coated (8C)
IOTA Size Nominal 6 inches (152 mm)
Redundancy Non-Redundant
Supported Channel Count 16 Circuits / Channels
Power Supply Input 24 VDC bus (screw-mounted to carrier bus)
Field Power Distribution Non-incendive output (no external field power required)
Terminal Connection Type Two-level detachable terminals
Maximum Wire Size Up to 12 AWG / 2.5 mm2 stranded wire
Compatible Output Modules 8C-PAOH51, 8U-PAOH51, 8C-PAON01, 8U-PAON01
Signal Output Type 4-20 mA
Output Ripple < 100 mV peak-to-peak at power line frequency across 250 ohm load
Resolution +/- 0.05% of Full Scale
Calibrated Accuracy +/- 0.35% of Full Scale (25 degC) including linearity
Settable Output Range 0 mA, 2.9 mA to 21.1 mA
Maximum Open Circuit Voltage 22 V

Connections/Interfaces

Connector / Interface Function
Detachable Field Terminals Two-level wiring terminals for 16-channel analog output field connections
Carrier Bus Connection Mechanical screw connections for receiving 24 VDC system power
IOM Mounting Interface Direct plug-in slot for Series 8 Analog Output Module
Network Connection Integrated connection to I/O Link network

Installation Guidelines

  • Mount vertically inside system cabinets to align with field wiring entry from cabinet top or bottom.
  • Ensure natural ventilation by using the tilted hardware design for thermal dissipation.
  • Screw the termination assembly directly onto the 24 VDC bussed power carrier.
  • Land field wiring on the two-level detachable terminals using stranded conductors up to 12 AWG (2.5 mm2).
  • Verify non-incendive wiring practices when installing in Class 1, Division 2 hazardous environments.

Compliance and Certifications

  • Class 1, Division 2 Hazardous Location Non-Incendive Rating

FAQ

What is the Honeywell 8C-TAOX51 51306983-175 used for?

The Honeywell 8C-TAOX51 51306983-175 is a conformal-coated 6-inch Input Output Termination Assembly (IOTA) used to hold Series 8 Analog Output modules and connect field wiring in PlantCruise process control systems.

Which system and modules are compatible with the 8C-TAOX51 IOTA?

The module belongs to the PlantCruise Series 8 architecture and supports 16-channel analog output modules, including 8C-PAOH51, 8U-PAOH51, 8C-PAON01, and 8U-PAON01.

How does the IOTA receive power?

The IOTA receives 24 VDC power directly through its mounting screws connected to the carrier power bus and distributes non-incendive power to field circuits.

What terminal wire gauge is supported by the device?

The detachable two-level field connectors on the IOTA accept stranded wire up to 12 AWG (2.5 mm2).

What is the difference between 8C-TAOX51 and 8U-TAOX51?

The 8C-TAOX51 features a conformal coating for environmental protection against dust, humidity, and chemicals, whereas the 8U-TAOX51 is uncoated.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell 8C-TAOX51 51306983-175 PlantCruise Series 8 Analog Output IOTA

Quantity
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 2 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
United States
Power source
DC Power

Technical knowledge

IC693DSM324 Replacement Checks: FSSB, Firmware and Follower Control

A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.

HIMA F3430 Replacement Checks: Contact Ratings and Safety Limits

A field-focused HIMA F3430 replacement guide covering relay contact ratings, DC load derating, fusing, F3330/F3331 differences, safety restrictions and commissioning records.

IC697PWR710 Replacement Checks: Load Budget and Dual-Rack Limits

A field-focused IC697PWR710 replacement guide covering 5 V load calculations, dual-rack limits, extension cables, input checks, protection behavior and hardware revision risks.

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks

A field checklist for diagnosing Allen-Bradley 1746-NR4 RTD and resistance inputs, including sensor curves, lead compensation, excitation current, filter timing and channel diagnostics.