Honeywell

Honeywell 900B16-0001 ControlEdge HC900 16-Slot I/O Chassis

SKU 900B16-0001

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: 900B16-0001

  • Country of origin:United States

  • Product Type: I/O Chassis

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 400g

  • Dimensions: 7cm x 14cm x 14.5cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Overview

The 900B16-0001 (900B16-0001) is a high-capacity 16-slot I/O rack designed for the Honeywell ControlEdge HC900 Process & Safety Controller system. This chassis serves as the physical and communication backbone for various HC900 I/O modules, including analog inputs/outputs and digital inputs/outputs. Engineered for modularity and scalability, the 900B16-0001 supports both standard process control and SIL 2 safety-related applications, providing a ruggedized mounting platform with integrated power distribution and backplane communications.

Detailed Specifications

Feature Technical Data
Manufacturer Honeywell
Model Number 900B16-0001
Product Series ControlEdge HC900 / Series 900
Total I/O Slots 16 Slots (for I/O modules)
Reserved Slots Dedicated slots for Power Supply and Scanner/CPU
Backplane Power Distributed 5V and 24V from Power Supply Module
Mounting Type Panel Mount (Internal Cabinet)
Safety Integrity Level SIL 2 Certified (when used with appropriate modules)
Operating Temperature 0 °C to 60 °C (32 °F to 140 °F)
Construction Industrial-grade aluminum/steel hybrid
Communication High-speed internal bus for I/O scanning

Structural Capabilities

The 900B16-0001 is designed to maximize I/O density within a single rack footprint. It facilitates the "hot-swap" capability of the HC900 system, allowing modules to be replaced while the rest of the rack remains powered and operational. The chassis includes integrated grounding points and terminal block connectors for the power supply, ensuring clean power delivery to sensitive analog instrumentation. It is a critical component for large-scale boiler control, thermal processing, and water treatment applications.

FAQs

Does this chassis include the Power Supply or CPU?

No, the 900B16-0001 is the empty 16-slot rack frame. The Power Supply (e.g., 900P01) and the CPU or Scanner module must be purchased and installed separately.

Can I mix safety and non-safety modules in this rack?

Yes, the HC900 architecture allows for the coexistence of non-safety and safety-critical I/O within the same chassis, provided the system configuration adheres to the Honeywell Safety Manual guidelines.

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
DC Power

Technical knowledge

Troubleshooting Beckhoff KL1512 Counter Inputs and Mapping

A field checklist for KL1512 signal thresholds, counter direction, process data and the KL1512-to-KS1512 wiring difference.

Troubleshooting Beckhoff EPP2008-0001 Output Faults

A field checklist for EPP2008-0001 current limits, supply voltage, channel LEDs, connector coding and load-related output faults.

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.