Description

Engineered for high-reliability process automation, the Honeywell 900C50-0360-00 serves as a central processing unit (CPU) within the Honeywell HC900 process controller platform. This module handles execution of complex control loops, sequential logic, and data acquisition tasks for medium-scale industrial environments. By providing dual-port Ethernet capabilities and modular architecture, the C50 CPU ensures seamless connectivity to Human-Machine Interfaces (HMIs), supervisory control systems (SCADA), and distributed smart I/O racks.

The hardware architecture of this CPU module is optimized for continuous processing applications, supporting both non-redundant and redundant controller configurations. It coordinates real-time digital and analog input/output processing, PID loop execution, and diagnostic monitoring across the backplane bus, maintaining process integrity in demanding industrial settings.

Features

  • Dual Ethernet Communication: Equipped with integrated Ethernet ports supporting Modbus TCP/IP and peer-to-peer protocols.
  • Redundancy Capability: Supports high-availability redundant CPU architecture to eliminate single points of failure.
  • Advanced Process Control: Capable of managing numerous analog control loops and thousands of discrete I/O points.
  • Diagnostics & Status LEDs: Real-time hardware diagnostics displayed via LED indicators for CPU status, communication state, and fault detection.
  • Flash Memory: Non-volatile flash memory for secure storage of control programs, configuration files, and system firmware.

Applications

  • Burner Management Systems (BMS) and boiler control
  • Water and wastewater filtration and distribution systems
  • Chemical and pharmaceutical batch reactor processing
  • Thermal processing, industrial furnaces, and kiln control
  • General pipeline monitoring and SCADA RTU integration

Technical Specifications

Manufacturer Honeywell
Model Number 900C50-0360-00
Series HC900 Series
Module Type Controller C50 CPU Module
Supported I/O Capacity Up to 2000 I/O points (configuration dependent)
Communication Protocols Modbus TCP/IP, Honeywell Peer-to-Peer (ELN)
Physical Ports Ethernet RJ45, Serial RS-485 / RS-232
Redundancy Support Yes
Operating Temperature 0 to 60 degC
Storage Temperature -40 to 85 degC
Relative Humidity 10% to 90% non-condensing
Shipping Weight 10.0 kg

Connections and Interfaces

Port/Terminal Function Description
Ethernet Port 1 (10/100 Base-T) Primary network connection, SCADA, HMI, and peer-to-peer communication
Ethernet Port 2 (10/100 Base-T) Redundant network link or secondary host interface
RS-485 Serial Port Modbus RTU Master/Slave link to local instruments or serial displays
RS-232 Port Local configuration, diagnostic tools, and engineering software connection

Installation Guidelines

  • Rack Mounting: Secure the CPU module firmly into the designated controller slot of the HC900 chassis before applying power.
  • Grounding: Ensure the chassis rack is connected to a low-impedance functional earth ground to minimize electromagnetic interference (EMI).
  • Thermal Management: Maintain a minimum clearance of 50 mm above and below the chassis for proper natural convection cooling. Do not block the ventilation slots.
  • Hot-Swapping: Observe system redundancy status before removing any CPU modules from active systems to prevent unexpected process shutdowns.

Compliance and Certifications

  • CE Compliant
  • UL Listed (US and Canada)
  • CSA Certified
  • FM Approved for Class I, Division 2 Hazardous Locations

FAQ

What is the primary function of the Honeywell 900C50-0360-00?

It is the central processing unit (CPU) for the Honeywell HC900 system, executing control logic, processing multi-channel loop algorithms, and managing system communication.

Does the 900C50-0360-00 CPU module support redundancy?

Yes, as a C50 class controller CPU, it supports fully redundant processor configurations to maximize uptime in critical control environments.

Which communication protocols are natively supported by this CPU?

The CPU natively supports Modbus TCP/IP (Client and Server), Serial Modbus RTU, and Honeywell proprietary peer-to-peer (ELN) communications over Ethernet.

What are the safe operating temperature limits for the C50 CPU?

The module is designed to operate reliably within an ambient temperature range of 0 to 60 degC.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Electromagnetic Induction in Industrial Coils

Understand how industrial coils create magnetic force, induce voltage, generate switching transients, and fail in relays, solenoids, transformers, motors, and proximity sensors. in service.

Designing Power and Communication Redundancy

Design control-system redundancy by mapping shared dependencies, separating power and network paths, defining failover behavior, exposing degraded operation, and proof-testing every tolerated fault.

Troubleshooting Industrial Control Cabinets Systematically

A structured control-cabinet troubleshooting method covering safe work, drawings, power paths, branch protection, DC supplies, return circuits, PLC outputs, fault records and repair verification.

Measuring Voltage in Industrial Control Circuits

A practical voltage-testing guide for industrial control panels, covering reference points, meter selection, live-dead-live checks, voltage drop, ghost voltage, stored energy and intermittent faults.

Building a Verifiable Lockout Tagout Procedure

A practical lockout tagout guide covering hazardous-energy identification, isolation, stored-energy control, verification, group work, temporary testing, restoration, inspections and audits.

Designing Compressed-Air Preparation at the Machine

A field guide to point-of-use compressed-air preparation covering filters, regulators, drains, dryers, lubrication, pressure loss, isolation, monitoring, commissioning and leak testing.