Honeywell

Honeywell 900C50-0360-00 HC900 Controller C50 CPU Module

SKU 900C50-0360-00

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: 900C50-0360-00

  • Country of origin:United States

  • Product Type: Controller CPUs

  • Payment: T/T, Western Union

  • Weight: 10000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Engineered for high-reliability process automation, the Honeywell 900C50-0360-00 serves as a central processing unit (CPU) within the Honeywell HC900 process controller platform. This module handles execution of complex control loops, sequential logic, and data acquisition tasks for medium-scale industrial environments. By providing dual-port Ethernet capabilities and modular architecture, the C50 CPU ensures seamless connectivity to Human-Machine Interfaces (HMIs), supervisory control systems (SCADA), and distributed smart I/O racks.

The hardware architecture of this CPU module is optimized for continuous processing applications, supporting both non-redundant and redundant controller configurations. It coordinates real-time digital and analog input/output processing, PID loop execution, and diagnostic monitoring across the backplane bus, maintaining process integrity in demanding industrial settings.

Features

  • Dual Ethernet Communication: Equipped with integrated Ethernet ports supporting Modbus TCP/IP and peer-to-peer protocols.
  • Redundancy Capability: Supports high-availability redundant CPU architecture to eliminate single points of failure.
  • Advanced Process Control: Capable of managing numerous analog control loops and thousands of discrete I/O points.
  • Diagnostics & Status LEDs: Real-time hardware diagnostics displayed via LED indicators for CPU status, communication state, and fault detection.
  • Flash Memory: Non-volatile flash memory for secure storage of control programs, configuration files, and system firmware.

Applications

  • Burner Management Systems (BMS) and boiler control
  • Water and wastewater filtration and distribution systems
  • Chemical and pharmaceutical batch reactor processing
  • Thermal processing, industrial furnaces, and kiln control
  • General pipeline monitoring and SCADA RTU integration

Technical Specifications

Manufacturer Honeywell
Model Number 900C50-0360-00
Series HC900 Series
Module Type Controller C50 CPU Module
Supported I/O Capacity Up to 2000 I/O points (configuration dependent)
Communication Protocols Modbus TCP/IP, Honeywell Peer-to-Peer (ELN)
Physical Ports Ethernet RJ45, Serial RS-485 / RS-232
Redundancy Support Yes
Operating Temperature 0 to 60 degC
Storage Temperature -40 to 85 degC
Relative Humidity 10% to 90% non-condensing
Shipping Weight 10.0 kg

Connections and Interfaces

Port/Terminal Function Description
Ethernet Port 1 (10/100 Base-T) Primary network connection, SCADA, HMI, and peer-to-peer communication
Ethernet Port 2 (10/100 Base-T) Redundant network link or secondary host interface
RS-485 Serial Port Modbus RTU Master/Slave link to local instruments or serial displays
RS-232 Port Local configuration, diagnostic tools, and engineering software connection

Installation Guidelines

  • Rack Mounting: Secure the CPU module firmly into the designated controller slot of the HC900 chassis before applying power.
  • Grounding: Ensure the chassis rack is connected to a low-impedance functional earth ground to minimize electromagnetic interference (EMI).
  • Thermal Management: Maintain a minimum clearance of 50 mm above and below the chassis for proper natural convection cooling. Do not block the ventilation slots.
  • Hot-Swapping: Observe system redundancy status before removing any CPU modules from active systems to prevent unexpected process shutdowns.

Compliance and Certifications

  • CE Compliant
  • UL Listed (US and Canada)
  • CSA Certified
  • FM Approved for Class I, Division 2 Hazardous Locations

FAQ

What is the primary function of the Honeywell 900C50-0360-00?

It is the central processing unit (CPU) for the Honeywell HC900 system, executing control logic, processing multi-channel loop algorithms, and managing system communication.

Does the 900C50-0360-00 CPU module support redundancy?

Yes, as a C50 class controller CPU, it supports fully redundant processor configurations to maximize uptime in critical control environments.

Which communication protocols are natively supported by this CPU?

The CPU natively supports Modbus TCP/IP (Client and Server), Serial Modbus RTU, and Honeywell proprietary peer-to-peer (ELN) communications over Ethernet.

What are the safe operating temperature limits for the C50 CPU?

The module is designed to operate reliably within an ambient temperature range of 0 to 60 degC.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

IC693DSM324 Replacement Checks: FSSB, Firmware and Follower Control

A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.

HIMA F3430 Replacement Checks: Contact Ratings and Safety Limits

A field-focused HIMA F3430 replacement guide covering relay contact ratings, DC load derating, fusing, F3330/F3331 differences, safety restrictions and commissioning records.

IC697PWR710 Replacement Checks: Load Budget and Dual-Rack Limits

A field-focused IC697PWR710 replacement guide covering 5 V load calculations, dual-rack limits, extension cables, input checks, protection behavior and hardware revision risks.

IC693CPU313 Memory Retention and Expansion Limits Before Replacement

A practical replacement guide for the GE Fanuc IC693CPU313, covering its embedded five-slot architecture, memory backup, firmware-dependent capacity and why it cannot use Series 90-30 expansion racks.

Bently Nevada 3500/40M vs 3500/42M: I/O and Channel Checks Before Replacement

A field-focused comparison of Bently Nevada 3500/40M and 3500/42M monitor inputs, channel-pair configuration, rear I/O options, external termination hardware and firmware checks before replacement.

Allen-Bradley 1746-NR4 RTD Faults: Wiring, Excitation, and Filter Checks