Honeywell

Honeywell CC-PCF901 Series C Control Firewall Module

SKU CC-PCF901

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: CC-PCF901

  • Country of origin:United States

  • Product Type: PLC Control Firewall Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 25.4 x 15.2 x 7.6 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Managing Fault Tolerant Ethernet (FTE) traffic within the Experion PKS control network requires robust physical layer routing, which is exactly what the Honeywell CC-PCF901 Control Firewall Module delivers. This industrial hardware module acts as a dedicated security and routing interface, distributing critical FTE cabling directly to multiple Series C Fieldbus Interface Modules (FIMs) and internal cabinet network nodes. By implementing the Honeywell CC-PCF901 within your control topology, you establish a reliable hardware-level defense against network disturbances, isolating critical C300 Controllers and associated Series C I/O modules from external network traffic anomalies.

Features

  • FTE Distribution: Provides clean, structured distribution of Fault Tolerant Ethernet connections inside the cabinet.
  • Controller Protection: Safeguards sensitive Honeywell C300 controllers and Series C I/O modules from broadcast storms and network congestion.
  • IOTA Mounting: Direct installation onto the CF9 Input/Output Termination Assembly (IOTA) simplifies cabling and cabinet architecture.
  • Industrial Hardening: Conformal coated construction protects internal circuitry against harsh process environments and particulate contamination.
  • Low Power Footprint: Highly efficient internal power conversion minimizes cabinet thermal loading and auxiliary power draw.

Applications

  • Honeywell Experion PKS process automation environments.
  • In-cabinet FTE network isolation and signal distribution hubs.
  • Petrochemical, power generation, and critical refining control architectures.
  • Distributed Control System (DCS) cybersecurity hardening configurations.

Technical Specifications

Parameter Specification Value
Manufacturer Honeywell
Model Number CC-PCF901
Series Name Experion PKS Series C
Module Type Control Firewall Module (CFM)
Nominal Supply Voltage 24 VDC
Current Consumption 0.112 A (112 mA) @ 24 VDC
Compatible IOTA Base CC-TCF901 (CF9 Termination Assembly)
Network Interface Fault Tolerant Ethernet (FTE)
Conformal Coating Standard G3 compliance for harsh environments
Operating Temperature 0 to 60 degC
Shipping Weight (Calculated) 2.0 kg
Package Dimensions (Calculated) 25.4 x 15.2 x 7.6 cm

Alternative Models & Compatibility

The CC-PCF901 is designed exclusively for Honeywell Series C architecture. It cannot be used interchangeably with legacy Series A or PMIO hardware assemblies. Ensure that your current Experion control software version supports the CF9 IOTA hardware before deploying replacement components.

Commissioning & Wiring Tips

Always verify the integrity of the ground path on the CC-TCF901 IOTA prior to snapping the module onto the base. Faulty or high-impedance cabinet grounding can result in erratic FTE signal degradation or hardware-level communication dropouts. Use high-quality shielded Ethernet cables for external FTE lines routing to the IOTA structure.

Installation Guidelines

CRITICAL WARNING Before performing any maintenance or swapping the control module, verify that the 24VDC system supply is completely powered down. Hot-swapping network components without system preparation can lead to electrostatic discharge damage or trigger unexpected controller switchovers.
1 Power down the relevant sector of the cabinet or the targeted IOTA base power feed.
2 Mount the CC-PCF901 module securely onto the CC-TCF901 (CF9) Input/Output Termination Assembly until the latch clicks.
3 Connect the FTE Yellow and FTE Green networks directly to their respective designated RJ45 physical ports.
4 Re-energize the assembly and verify the internal network link diagnostic LEDs display normal operational statuses.

FAQ

What is the primary function of the Honeywell CC-PCF901?

The CC-PCF901 serves as a physical layer Control Firewall Module within the Honeywell Experion PKS Series C environment. It distributes Fault Tolerant Ethernet (FTE) cabling configurations safely to multiple local control nodes, isolating sensitive C300 controllers from network disturbances.

Which termination assembly is compatible with this module?

The CC-PCF901 mounts directly on the CC-TCF901 CF9 Input/Output Termination Assembly (IOTA) base.

What are the electrical power requirements for this firewall unit?

The module requires a clean nominal 24 VDC input supply, with a rated operational current draw of approximately 0.112 Amps (112 mA).

Can the CC-PCF901 be used in corrosive process atmospheres?

Yes, this Honeywell module features a conformal coating that meets G3 classification requirements, protecting sensitive components against corrosion and humidity.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.

Securing Remote PLC Access Beyond the VPN

A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...