Honeywell

Honeywell FC-TSGASH-1624P Safety Manager Field Termination Assembly

SKU FC-TSGASH-1624P V1.0

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: FC-TSGASH-1624P V1.0
  • Origin United States
  • Product Type: Field Termination Assembly
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.65 kg
  • Dimensions: 225 x 109 x 60 mm (L x W x H)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell FC-TSGASH-1624P Safety Manager Field Termination Assembly

Quantity

Product Description

Description

The Honeywell FC-TSGASH-1624P V1.0 is a safe gas and flame detector input Field Termination Assembly (FTA) designed as an interface module between 0–20 mA field transmitters and the SAI-1620m safe high-density analog input module within Honeywell Safety Manager systems. Featuring 16 input channels, this assembly supports both safety-related and non-safety-related instrumentation loops in industrial safety instrumented systems (SIS).

Each channel on the FC-TSGASH-1624P V1.0 incorporates a high-precision 500 Ohm resistor to convert input current signals into 0–4 VDC levels for processing by the SAI-1620m module with 0.1% accuracy. To safeguard connected instrumentation and loop wiring, every channel is individually protected by a 500 mA fast-acting fuse. The module routes input signals to single or redundant SAI-1620m modules using standard SICC-0001/Lx system interconnection cables.

In addition to primary signal conversion, the FC-TSGASH-1624P V1.0 features dedicated interfaces for HART communication. By providing direct connection points for multiplexer solutions from MTL or Pepperl+Fuchs (P+F), the module enables online HART diagnostic passthrough without disrupting safety loop integrity. The assembly is built on a DIN EN rail snap-in footprint and powered via a 24 VDC external supply line.

Features

  • 16-Channel Analog Interface: Accommodates up to sixteen 0–20 mA (0–25 mA maximum) gas and flame detector loops with a shared common 0 V connection.
  • Precision Signal Conversion: High-accuracy 500 Ohm onboard resistors convert input current signals to 0–4 VDC output levels for the SAI-1620m module.
  • Individual Channel Fusing: Equipped with 500 mA Schurter fuses (5x20 mm) per channel to protect field power lines and field devices against short-circuit events.
  • Integrated HART Multiplexer Support: Dedicated onboard CN2 and CN3 connectors enable direct integration with Pepperl+Fuchs and MTL HART multiplexer solutions using standard cable assemblies.
  • Dedicated Shield Connections: Features 16 dedicated screw terminals designed for field cable shield grounding, optimizing noise immunity in critical monitoring applications.
  • External Power Supply Voltage Monitoring: Allows Safety Manager software to continuously monitor connected 24 VDC supply voltage levels through the safe high-density analog input chassis.
  • Dual DIN Rail Compatibility: Mounting provision supports both TS32 and TS35 x 7.5 DIN EN rails for flexible cabinet installations.

Applications

  • Safety Instrumented Systems (SIS): Field wiring termination for combustible gas, toxic gas, and optical flame detectors connected to Honeywell Safety Manager systems.
  • Process Safety Management: Analog input signal conditioning and HART diagnostic integration for critical 2-wire and 3-wire field transmitters.
  • HART Asset Management Integration: Passthrough connection point for MTL4850 or Pepperl+Fuchs HART multiplexers to support remote instrument calibration and device health monitoring.

Technical Specifications

General

Parameter Specification
Manufacturer Honeywell
Exact Model Number FC-TSGASH-1624P V1.0
Part Number TSGASH-1624P
Product Type Safe Gas/Flame Detector Input Field Termination Assembly (FTA)
System Platform Safety Manager
Input Channels 16 Analog Inputs
Accuracy 0.1%

Electrical & Input Ratings

Parameter Specification
Power Supply Requirement 24 VDC external, 2.5 mA (without field loads)
Input Current Range 0–25 mA (0–20 mA nominal)
Input Resistance 500 Ohm (+/- 5%)
Output Voltage to SAI-1620m 0–4 VDC
Output Voltage to HART Multiplexer Max. 11 V peak-to-peak
HART Series Impedance > 2 uF

Protection & Fusing

Parameter Specification
Fuse Rating 500 mA
Fuse Dimensions 5 x 20 mm
Fuse Manufacturer & Part Number Schurter 0001.2501
Fuse Voltage Ratings 250 VAC / 300 VDC
Fuse Derating Curve Linear from 0.5 A at 25 degC to 0.35 A at 70 degC ambient

Mechanical & Environmental

Parameter Specification
Dimensions (L x W x H) 225 x 109 x 60 mm (8.86 x 4.29 x 2.36 in)
Used Rail Length 226 mm (8.90 in)
Compatible DIN EN Rails TS32 / TS35 x 7.5
Screw Terminal Wire Diameter Max. 2.5 mm2 (AWG 14)
Screw Terminal Strip Length 7 mm (0.28 in)
Screw Terminal Tightening Torque 0.5 Nm (0.37 ft-lb)

Connections / Interfaces

Interface / Pin Function
Screw Terminals 1 to 64 Field wiring connections arranged in 16 groups of 4 screw terminals, including dedicated channel ground terminals
Ground Screw Terminals Top left ground connections for earth bonding field cable shields
Power Connector (+) Pin 1 connected to +24 VDC bus bar via Weidmuller BVZ 7.62HP/02/180F SN connector
Power Connector (-) Pin 2 connected to 0 VDC bus bar via Weidmuller BVZ 7.62HP/02/180F SN connector
CN1 Connector Interface for SICC-0001/Lx cable to SAI-1620m analog input module
CN2 Connector Dedicated interface for Pepperl+Fuchs HART multiplexer units (KFD0-HMS-16 or KFD2-HMM-16 via K-MH26 cable)
CN3 Connector Dedicated interface for MTL HART multiplexer units (MTL4850 via MTL FLAT20-2.2 cable)

Installation Guidelines

  1. Pre-Installation Inspection: Verify physical integrity and check that all 16 channel fuses (500 mA, 5x20 mm) are fully seated in their respective holders before mounting.
  2. DIN Rail Mounting: Snap the assembly securely onto a standard TS32 or TS35 x 7.5 DIN rail within the control cabinet, allowing at least 226 mm of clear rail width.
  3. Power Wiring Connection: Strip external 24 VDC power conductors to 8 mm (0.28 in). Connect the supply lines to the included keyed Weidmuller BVZ 7.62HP 2-pole plug, ensuring proper polarity (+ to Pin 1, - to Pin 2), and engage the red locking slides.
  4. Field Signal Wiring: Connect 2-wire or 3-wire gas and flame detectors to screw terminal groups 1 through 64. Strip wires to 7 mm (0.28 in) and tighten terminal screws to a torque of 0.5 Nm.
  5. Shield Grounding: Connect individual field cable shield drain wires to the dedicated shield terminal on each channel group and bond cabinet earth ground to the top-left ground screw connections.
  6. System Interconnection: Connect the SICC-0001/Lx cable from connector CN1 on the FTA to the primary (or redundant pair) SAI-1620m module in the Safety Manager chassis.

Commissioning & Maintenance Recommendations

  • External Power Verification: Confirm that Safety Manager software detects normal external supply voltage levels across the assembly via the SAI-1620m module diagnostic interface.
  • Fuse Replacement: If a transmitter loop fails, check the corresponding channel fuse (F1 to F16). Replace blown fuses exclusively with Schurter 0001.2501 (500 mA, 5x20 mm, 250 VAC / 300 VDC) fuses to maintain safety compliance.
  • HART Integration Check: When using external HART multiplexers, verify that the dedicated CN2 (P+F) or CN3 (MTL) ribbon cables are fully seated and that loop communications function without signal attenuation.

Compliance and Certifications

  • CE Mark: European Conformity
  • TUV: Safety Approved for High-Integrity Applications
  • UL Listed: Underwriters Laboratories Standard Compliance
  • CSA Certified: Canadian Standards Association Certified
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What primary function does the Honeywell FC-TSGASH-1624P V1.0 serve in a Safety Manager system?
The Honeywell FC-TSGASH-1624P V1.0 acts as a field termination assembly that interfaces 16 field-mounted 0–20 mA gas or flame detectors with the SAI-1620m safe high-density analog input module, providing signal conditioning, power distribution, and channel fusing.
How does the Honeywell FC-TSGASH-1624P V1.0 handle HART protocol communications?
The assembly features dedicated onboard connectors CN2 and CN3 to interface directly with HART multiplexer units from Pepperl+Fuchs (KFD0-HMS-16 / KFD2-HMM-16) or MTL (MTL4850), allowing HART diagnostic data pass-through without interrupting safety inputs.
What type of fuses are required for channel protection on the Honeywell FC-TSGASH-1624P V1.0?
Each channel on the assembly utilizes a 500 mA fast-acting fuse. The manufacturer specified replacement is a Schurter 0001.2501 fuse measuring 5x20 mm with ratings of 250 VAC and 300 VDC.
How connects power to the Honeywell FC-TSGASH-1624P V1.0 module?
External 24 VDC power connects through a 2-pole keyed Weidmuller BVZ 7.62HP/02/180F SN connector, where Pin 1 connects to the +24 VDC bus bar and Pin 2 connects to the 0 VDC bus bar.
Reviews

FC-TSGASH-1624P V1.0

Stock & lead time on request

Call
1 of 4

Honeywell FC-TSGASH-1624P Safety Manager Field Termination Assembly

Only 8 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: FC-TSGASH-1624P V1.0

  • Country of origin:United States

  • Product Type: Field Termination Assembly

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 650g

  • Dimensions: 225 x 109 x 60 mm (L x W x H)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Honeywell FC-TSGASH-1624P V1.0 is a safe gas and flame detector input Field Termination Assembly (FTA) designed as an interface module between 0–20 mA field transmitters and the SAI-1620m safe high-density analog input module within Honeywell Safety Manager systems. Featuring 16 input channels, this assembly supports both safety-related and non-safety-related instrumentation loops in industrial safety instrumented systems (SIS).

Each channel on the FC-TSGASH-1624P V1.0 incorporates a high-precision 500 Ohm resistor to convert input current signals into 0–4 VDC levels for processing by the SAI-1620m module with 0.1% accuracy. To safeguard connected instrumentation and loop wiring, every channel is individually protected by a 500 mA fast-acting fuse. The module routes input signals to single or redundant SAI-1620m modules using standard SICC-0001/Lx system interconnection cables.

In addition to primary signal conversion, the FC-TSGASH-1624P V1.0 features dedicated interfaces for HART communication. By providing direct connection points for multiplexer solutions from MTL or Pepperl+Fuchs (P+F), the module enables online HART diagnostic passthrough without disrupting safety loop integrity. The assembly is built on a DIN EN rail snap-in footprint and powered via a 24 VDC external supply line.

Features

  • 16-Channel Analog Interface: Accommodates up to sixteen 0–20 mA (0–25 mA maximum) gas and flame detector loops with a shared common 0 V connection.
  • Precision Signal Conversion: High-accuracy 500 Ohm onboard resistors convert input current signals to 0–4 VDC output levels for the SAI-1620m module.
  • Individual Channel Fusing: Equipped with 500 mA Schurter fuses (5x20 mm) per channel to protect field power lines and field devices against short-circuit events.
  • Integrated HART Multiplexer Support: Dedicated onboard CN2 and CN3 connectors enable direct integration with Pepperl+Fuchs and MTL HART multiplexer solutions using standard cable assemblies.
  • Dedicated Shield Connections: Features 16 dedicated screw terminals designed for field cable shield grounding, optimizing noise immunity in critical monitoring applications.
  • External Power Supply Voltage Monitoring: Allows Safety Manager software to continuously monitor connected 24 VDC supply voltage levels through the safe high-density analog input chassis.
  • Dual DIN Rail Compatibility: Mounting provision supports both TS32 and TS35 x 7.5 DIN EN rails for flexible cabinet installations.

Applications

  • Safety Instrumented Systems (SIS): Field wiring termination for combustible gas, toxic gas, and optical flame detectors connected to Honeywell Safety Manager systems.
  • Process Safety Management: Analog input signal conditioning and HART diagnostic integration for critical 2-wire and 3-wire field transmitters.
  • HART Asset Management Integration: Passthrough connection point for MTL4850 or Pepperl+Fuchs HART multiplexers to support remote instrument calibration and device health monitoring.

Technical Specifications

General

Parameter Specification
Manufacturer Honeywell
Exact Model Number FC-TSGASH-1624P V1.0
Part Number TSGASH-1624P
Product Type Safe Gas/Flame Detector Input Field Termination Assembly (FTA)
System Platform Safety Manager
Input Channels 16 Analog Inputs
Accuracy 0.1%

Electrical & Input Ratings

Parameter Specification
Power Supply Requirement 24 VDC external, 2.5 mA (without field loads)
Input Current Range 0–25 mA (0–20 mA nominal)
Input Resistance 500 Ohm (+/- 5%)
Output Voltage to SAI-1620m 0–4 VDC
Output Voltage to HART Multiplexer Max. 11 V peak-to-peak
HART Series Impedance > 2 uF

Protection & Fusing

Parameter Specification
Fuse Rating 500 mA
Fuse Dimensions 5 x 20 mm
Fuse Manufacturer & Part Number Schurter 0001.2501
Fuse Voltage Ratings 250 VAC / 300 VDC
Fuse Derating Curve Linear from 0.5 A at 25 degC to 0.35 A at 70 degC ambient

Mechanical & Environmental

Parameter Specification
Dimensions (L x W x H) 225 x 109 x 60 mm (8.86 x 4.29 x 2.36 in)
Used Rail Length 226 mm (8.90 in)
Compatible DIN EN Rails TS32 / TS35 x 7.5
Screw Terminal Wire Diameter Max. 2.5 mm2 (AWG 14)
Screw Terminal Strip Length 7 mm (0.28 in)
Screw Terminal Tightening Torque 0.5 Nm (0.37 ft-lb)

Connections / Interfaces

Interface / Pin Function
Screw Terminals 1 to 64 Field wiring connections arranged in 16 groups of 4 screw terminals, including dedicated channel ground terminals
Ground Screw Terminals Top left ground connections for earth bonding field cable shields
Power Connector (+) Pin 1 connected to +24 VDC bus bar via Weidmuller BVZ 7.62HP/02/180F SN connector
Power Connector (-) Pin 2 connected to 0 VDC bus bar via Weidmuller BVZ 7.62HP/02/180F SN connector
CN1 Connector Interface for SICC-0001/Lx cable to SAI-1620m analog input module
CN2 Connector Dedicated interface for Pepperl+Fuchs HART multiplexer units (KFD0-HMS-16 or KFD2-HMM-16 via K-MH26 cable)
CN3 Connector Dedicated interface for MTL HART multiplexer units (MTL4850 via MTL FLAT20-2.2 cable)

Installation Guidelines

  1. Pre-Installation Inspection: Verify physical integrity and check that all 16 channel fuses (500 mA, 5x20 mm) are fully seated in their respective holders before mounting.
  2. DIN Rail Mounting: Snap the assembly securely onto a standard TS32 or TS35 x 7.5 DIN rail within the control cabinet, allowing at least 226 mm of clear rail width.
  3. Power Wiring Connection: Strip external 24 VDC power conductors to 8 mm (0.28 in). Connect the supply lines to the included keyed Weidmuller BVZ 7.62HP 2-pole plug, ensuring proper polarity (+ to Pin 1, - to Pin 2), and engage the red locking slides.
  4. Field Signal Wiring: Connect 2-wire or 3-wire gas and flame detectors to screw terminal groups 1 through 64. Strip wires to 7 mm (0.28 in) and tighten terminal screws to a torque of 0.5 Nm.
  5. Shield Grounding: Connect individual field cable shield drain wires to the dedicated shield terminal on each channel group and bond cabinet earth ground to the top-left ground screw connections.
  6. System Interconnection: Connect the SICC-0001/Lx cable from connector CN1 on the FTA to the primary (or redundant pair) SAI-1620m module in the Safety Manager chassis.

Commissioning & Maintenance Recommendations

  • External Power Verification: Confirm that Safety Manager software detects normal external supply voltage levels across the assembly via the SAI-1620m module diagnostic interface.
  • Fuse Replacement: If a transmitter loop fails, check the corresponding channel fuse (F1 to F16). Replace blown fuses exclusively with Schurter 0001.2501 (500 mA, 5x20 mm, 250 VAC / 300 VDC) fuses to maintain safety compliance.
  • HART Integration Check: When using external HART multiplexers, verify that the dedicated CN2 (P+F) or CN3 (MTL) ribbon cables are fully seated and that loop communications function without signal attenuation.

Compliance and Certifications

  • CE Mark: European Conformity
  • TUV: Safety Approved for High-Integrity Applications
  • UL Listed: Underwriters Laboratories Standard Compliance
  • CSA Certified: Canadian Standards Association Certified
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell FC-TSGASH-1624P Safety Manager Field Termination Assembly

What primary function does the Honeywell FC-TSGASH-1624P V1.0 serve in a Safety Manager system?

The Honeywell FC-TSGASH-1624P V1.0 acts as a field termination assembly that interfaces 16 field-mounted 0–20 mA gas or flame detectors with the SAI-1620m safe high-density analog input module, providing signal conditioning, power distribution, and channel fusing.

How does the Honeywell FC-TSGASH-1624P V1.0 handle HART protocol communications?

The assembly features dedicated onboard connectors CN2 and CN3 to interface directly with HART multiplexer units from Pepperl+Fuchs (KFD0-HMS-16 / KFD2-HMM-16) or MTL (MTL4850), allowing HART diagnostic data pass-through without interrupting safety inputs.

What type of fuses are required for channel protection on the Honeywell FC-TSGASH-1624P V1.0?

Each channel on the assembly utilizes a 500 mA fast-acting fuse. The manufacturer specified replacement is a Schurter 0001.2501 fuse measuring 5x20 mm with ratings of 250 VAC and 300 VDC.

How connects power to the Honeywell FC-TSGASH-1624P V1.0 module?

External 24 VDC power connects through a 2-pole keyed Weidmuller BVZ 7.62HP/02/180F SN connector, where Pin 1 connects to the +24 VDC bus bar and Pin 2 connects to the 0 VDC bus bar.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Dots
Country of origin
United States

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...