Honeywell

Honeywell MC-PLAM02 51304362-150 Low-Level Multiplexer IOP

SKU MC-PLAM02 51304362-150

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: MC-PLAM02 51304362-150

  • Product Type: Low-Level Multiplexer IOP

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 620g

  • Dimensions: 3 cm × 31.8 cm × 27.8 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Product overview

The Honeywell MC-PLAM02, part number 51304362-150, is the conformally coated low-level multiplexer I/O processor (LLMux IOP) used in Honeywell Process Manager/HPM and later Experion migration contexts. Historical planning records associate the processor with up to 32 low-level thermocouple, RTD or millivolt inputs through the correct field termination assembly.

Technical specifications

Manufacturer Honeywell
Model MC-PLAM02
Part number 51304362-150
Product type Low-Level Multiplexer IOP
Coating / compliance identifier Conformally coated, CE-compliant assembly in historical planning tables
Input role Low-level thermocouple, RTD and millivolt multiplexed inputs
Documented capacity Up to 32 inputs with the correct FTA/configuration
System context TDC 3000 Process Manager / HPM; migration-dependent Experion use
Listing-reference dimensions 3 × 31.8 × 27.8 cm
Listing-reference net weight 0.62 kg

Compatibility and replacement boundary

The IOP does not define the field wiring by itself. Confirm the paired FTA, sensor type, database configuration, scan requirements, coating/revision and controller release. Do not substitute MC-PLAM02 for a different low-level analog processor solely because the connector format appears similar.

Dimensions and shipping

Estimated package: 40 × 36 × 10 cm; estimated shipping weight 1.4 kg. Use antistatic protection and confirm warehouse measurements.

FAQ

What is MC-PLAM02 51304362-150?

It is a conformally coated Honeywell low-level analog multiplexer I/O processor.

How many inputs can it support?

Historical system planning records describe up to 32 low-level inputs when used with the correct FTA and configuration.

Does the card accept field wires directly?

The processor works with a matched field termination assembly; verify the installed FTA and cabling.

Which signals are associated with LLMux service?

Thermocouple, RTD and low-level millivolt measurements are typical, but the configured sensor types must be checked in the control database.

Are the package values exact?

No. They are estimated for shipping and must be confirmed by the warehouse.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 5 item(s) left in stock
Quantity
View full details
Loading product navigation…

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

No detailed specifications found for this SKU.

Technical knowledge

1746-A7 Chassis Replacement Checks: Slots, Power and Interconnects

An engineering checklist for replacing an Allen-Bradley 1746-A7: verify chassis series, backplane loading, slot plan, interconnect cables, mounting, grounding and receiving condition.

IC200MDL650 Replacement Checks: Logic Polarity, Filters, and Commons

A field replacement guide for GE Fanuc IC200MDL650 covering revision-dependent negative logic, four common groups, 24 VDC thresholds, input filtering, carrier checks and commissioning records.

IC697CPX935 Replacement Checks: Memory, Ports, and Rack Power

A field-focused IC697CPX935 replacement guide covering fast memory, firmware-dependent serial behavior, rack power, cooling, I/O architecture and backup records.

IC693DSM324 Replacement Checks: FSSB, Firmware and Follower Control

A field-focused IC693DSM324 replacement guide covering Series 90-30 host checks, FSSB servo-chain records, 5 V power budget, firmware limits, follower control and commissioning.

HIMA F3430 Replacement Checks: Contact Ratings and Safety Limits

A field-focused HIMA F3430 replacement guide covering relay contact ratings, DC load derating, fusing, F3330/F3331 differences, safety restrictions and commissioning records.

IC697PWR710 Replacement Checks: Load Budget and Dual-Rack Limits

A field-focused IC697PWR710 replacement guide covering 5 V load calculations, dual-rack limits, extension cables, input checks, protection behavior and hardware revision risks.