Honeywell

Honeywell MU-KFTA05 51201420-005 TPS Process Manager FTA Cable

SKU MU-KFTA05 51201420-005

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: MU-KFTA05 51201420-005

  • Country of origin:United States

  • Product Type: FTA Cable

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 350g

  • Dimensions: 200 mm x 150 mm x 30 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Honeywell MU-KFTA05 51201420-005 is a Field Termination Assembly (FTA) cable designed for integration within the Honeywell TotalPlant Solution (TPS) Process Manager system architecture. It connects Field Termination Assemblies to I/O Processors (IOP) in Process Manager (PM), Advanced Process Manager (APM), and High Process Manager (HPM) system environments. Engineered for industrial automation and process control, this interconnecting cable facilitates system wiring between cabinet-mounted I/O card files and field interface points.

Features

  • System Interconnection: Connects I/O Processors (IOP) directly to Field Termination Assemblies (FTA) within Process Manager subsystem configurations.
  • Industrial Construction: Manufactured to Honeywell Process Manager specifications for signal integrity and system wiring.
  • System Integration: Fully compatible with Honeywell Process Manager, APM, and HPM card file assemblies and FTAs.

Applications

  • Honeywell TPS Process Manager I/O subsystem interconnections
  • Advanced Process Manager (APM) and High Process Manager (HPM) cabinet wiring
  • Connecting I/O Processors to Field Termination Assemblies

Ordering Information

Model Number Description
MU-KFTA05 FTA Cable

Technical Specifications

Category Parameter Specification
General Model Number MU-KFTA05
  Part Number 51201420-005
  System Compatibility Honeywell TPS Process Manager, APM, HPM
  Component Type Field Termination Assembly (FTA) Cable

Installation Guidelines

  • Cable Routing: Route the FTA cable through designated wiring channels within the cabinet to avoid excessive strain or sharp bends.
  • Connection Security: Ensure both cable connectors are properly seated and secured to the I/O Processor card file and Field Termination Assembly connectors.
  • Cabinet Environment: Install within process control cabinets maintaining operational ambient temperatures and protection from physical damage.

FAQ

What is the primary function of the cable?

The cable connects Field Termination Assemblies to I/O Processors within the Process Manager system architecture.

Which system platforms support this component?

The cable is compatible with Honeywell Process Manager, Advanced Process Manager, and High Process Manager systems.

What is the part number associated with this model?

The model MU-KFTA05 corresponds to part number 51201420-005.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.