1 of 1

KL9510 | BECKHOFF | Power Supply Terminal 5 V to 15 V DC

KL9510 | BECKHOFF | Power Supply Terminal 5 V to 15 V DC

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KL9510

  • Country of origin:Germany

  • Product Type: Power supply unit terminals 5 V

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The KL9510 is a versatile power supply terminal from Beckhoff, part of a series (including KL9505, KL9508, KL9510, KL9512, and KL9515) engineered to generate specific regulated output voltages from a standard 24 V DC input. This module provides a stable output voltage to the local Bus Terminal system, distributing power efficiently via the integrated power contacts to downstream terminals. Featuring built-in status monitoring, the KL9510 utilizes power LEDs to provide immediate visual feedback on the terminal's operating state.

Features

  • Generates regulated output voltage from 24 V DC input
  • Power distribution to adjacent Bus Terminals via power contacts
  • Integrated power LEDs for real-time operating state indication
  • Compact design for seamless integration into the Bus Terminal system
  • Compatible with the broader range of Beckhoff power supply unit terminals

Technical Specifications

Feature Specification
Manufacturer Beckhoff
Model KL9510
Input Voltage 24 V DC
Output Voltage 10 V DC
Compatibility KL95xx Series
Electrical Isolation No isolation between input and output U0
Indicators Power LEDs

Installation Guidelines

  • Integration: The KL9510 is designed to be snapped onto standard 35 mm DIN rails. Ensure the power contacts are correctly aligned to allow for voltage distribution to neighboring terminals.
  • Power Distribution: Note that the output voltage generated is supplied to downstream Bus Terminals through the power contacts. Ensure that the total current draw of the connected terminal segment does not exceed the rated limits.
  • Electrical Safety: The input and output voltages are not electrically isolated. Ensure your system design accounts for this non-isolated configuration when connecting to peripheral sensors or actuators.
  • Monitoring: Use the integrated power LEDs as a primary diagnostic tool to confirm that the terminal is receiving input power and successfully generating the required output voltage.

What is the input and output voltage of the KL9510?

The KL9510 accepts a 24 V DC input and generates a 10 V DC output.

Are the input and output voltages electrically isolated?

No, the input voltage and the output voltage are not electrically isolated in the KL9510.

How is power supplied to other Bus Terminals?

Power is distributed to adjacent Bus Terminals via the module's internal power contacts.

How do I check the operating status of the terminal?

You can monitor the operating state by checking the integrated power LEDs on the front of the terminal.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
White
Country of origin
Germany
Power source
DC Power

Recently Viewed Products

Technical knowledge

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...