Lenze

Lenze E82ZAFCC 8200-Series CAN/System Bus Function Module

SKU E82ZAFCC

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Lenze

  • Product No.: E82ZAFCC

  • Country of origin:Germany

  • Product Type: Function Modules

  • Barcode: 85044095

  • Payment: T/T, Western Union

  • Weight: 100g

  • Dimensions: 15,20cm x 10,20cm x 10,20cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Product Overview

The Lenze E82ZAFCC (E82ZAFCC) is a specialized function module engineered to expand the communication capabilities of the 8200-series inverter range. Serving as a dedicated interface for CAN/System Bus protocols, this module allows for seamless integration of the drive into distributed automation architectures. By providing a reliable communication link between the drive and the higher-level control network, the E82ZAFCC facilitates high-speed data exchange, precise motion synchronization, and centralized diagnostic monitoring. This is particularly vital in industrial applications such as multi-axis transport systems and automated assembly lines, where maintaining consistent bus communication is critical to preventing system-wide faults and optimizing machine cycle times.

Technical Configuration

The E82ZAFCC is designed as a plug-in expansion module that mounts directly to the 8200-series inverter hardware, ensuring a robust and vibration-resistant physical connection. Its internal logic is dedicated to interpreting CAN/System Bus telegrams, translating them into drive commands with minimal latency. The hardware is built with industrial-grade transceivers capable of maintaining signal integrity over extended cabling distances within high-EMI environments. The module features standardized terminals for bus connectivity, allowing for easy integration into existing network topologies while requiring minimal cabinet space. Its efficient energy footprint ensures it operates well within the thermal limits of the host drive, supporting reliable performance throughout the lifecycle of the automation system.

Technical Specifications

Feature Specification
Model E82ZAFCC
Brand Lenze
Series 8200-series
Product Type Function modules
Weight 0.10 kg
Dimensions 15.20 x 10.20 x 10.20 cm
Lifecycle Status Phase-Out
Bus Protocol CAN / System Bus
Commodity Code 85044095

FAQs

Is the E82ZAFCC compatible with all 8200-series inverters?

Yes, this module is the standard interface for CAN/System Bus communications across the 8200-series platform. Verify that your specific inverter firmware supports the intended bus communication functions.

How is the module addressed on the CAN bus?

Node addressing and baud rate settings are typically configured via the drive's parameter menu, which recognizes the module upon power-up. Refer to the 8200-series system manual for specific parameter indices.

What is the significance of the phase-out status for this module?

The phase-out status indicates that the component is nearing the end of its lifecycle. We maintain active original stock to provide reliable replacements for existing installations, ensuring your network communication remains stable.

What are the common symptoms of a module communication failure?

Symptoms include "Bus Off" errors on the host PLC, intermittent communication timeouts, or drive fault codes indicating a loss of control-link synchronization. Always check the physical bus termination resistors at both ends of the line if communication issues persist.

Installation and Operational Guidelines

  • Bus Termination: To ensure reliable CAN bus communication, always install a 120-ohm termination resistor at both extreme ends of the network. Failure to terminate the bus correctly can lead to signal reflections and erratic data transmission.

  • Signal Shielding: Use twisted-pair, shielded cabling for all CAN/System Bus connections. Ensure the shield is properly grounded at a single point to prevent ground loops, which can induce noise into the sensitive communication circuitry.

  • Handling Precautions: As a sensitive communication interface, the E82ZAFCC is susceptible to electrostatic discharge (ESD). Always handle the module by its casing and utilize a grounded wrist strap during installation or removal from the drive housing to protect the internal electronic components.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 6
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
White Greyish White
Country of origin
Germany

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...