Description
Integration of frequency inverters into centralized fieldbus networks is simplified using the E82ZAFPC010 PROFIBUS DP communication function module. Engineered specifically for the Lenze 8200-series frequency inverters, this pluggable interface module enables high-speed cyclic data exchange between a master PLC or host controller and the drive system. By establishing a reliable digital communication link, the module allows for precise control, parameterization, and real-time diagnostics of the connected drive, reducing wiring complexity and improving overall system response times.
This communication module mounts directly onto the front interface slot of the inverter, drawing its control power directly from the host drive. It supports standard PROFIBUS DP transmission rates and integrates seamlessly into existing industrial control architectures, making it a critical component for maintaining or upgrading legacy automation networks.
Features
- Designed for seamless mechanical and electrical integration with Lenze 8200-series vector inverters.
- Supports standard PROFIBUS DP communication protocol for high-speed cyclic data transfer.
- Pluggable architecture allows for rapid installation, configuration, and field replacement.
- Direct bus connection reduces hardwired control lines and simplifies diagnostic troubleshooting.
- Powered directly via the drive's internal interface slot, eliminating the need for external auxiliary power supplies.
Applications
- Factory automation and centralized machine control networks.
- Conveyor systems and material handling applications requiring synchronized drive control.
- Packaging machinery and production lines integrated via PROFIBUS DP networks.
- Water treatment and HVAC systems utilizing distributed drive architectures.
Technical Specifications
Parameter
Value
| Manufacturer |
Lenze |
| Part Number/Model |
E82ZAFPC010 |
| Series |
8200-series |
| Module Type |
Communication Function Module |
| Communication Protocol |
PROFIBUS DP |
| Product Phase |
Phase-Out |
| Weight |
0.10 kg |
| Dimensions (W x H x D) |
5.10 cm x 7.60 cm x 2.50 cm |
| Commodity Code |
85044095 |
Installation Guidelines
To ensure safe and reliable operation, adhere to the following installation procedures:
-
Power Isolation: Disconnect all electrical power from the frequency inverter and wait for the internal DC-bus capacitors to fully discharge before mounting or removing the communication module.
-
Mounting: Carefully align the module's connector pins with the interface slot on the front of the 8200-series inverter. Press firmly until the module is fully seated, and secure any integrated retaining screws to ensure solid grounding.
-
Shielding and Grounding: Use only approved, high-quality shielded twisted-pair cables specified for PROFIBUS DP networks. Ensure the cable shield is grounded at both ends to prevent electromagnetic interference (EMI) from disrupting data transmission.
-
Bus Termination: Ensure that proper bus termination resistors are activated or installed at the first and last physical nodes of the PROFIBUS network segment.