Product Overview

The Lenze E94AYCER (E94AYCER) is a specialized Ethernet communication extension module designed to expand the connectivity of the 9400-series servo drive family. By integrating this module, system integrators can transition from traditional fieldbus architectures to high-speed Ethernet-based networks, enabling real-time data exchange, remote diagnostic capabilities, and seamless synchronization within complex multi-axis motion control systems. Its design prioritizes ease of integration, allowing for plug-and-play functionality that minimizes downtime during system upgrades or the deployment of new automation nodes.

Technical Configuration

The E94AYCER serves as the communication gateway for the 9400-series, translating drive-internal parameters into standardized Ethernet protocol packets.

  • Communication Interface: Provides high-speed Ethernet connectivity, supporting the high-bandwidth requirements of modern industrial networks.
  • System Integration: Built specifically for the 9400-series platform, the module mounts directly to the drive, maintaining a clean and compact cabinet footprint.
  • Protocol Support: Facilitates integration with standard automation controllers (PLCs) and HMI interfaces, enabling centralized control of drive parameters, status monitoring, and motion profile management.
  • Diagnostic Utility: Enables remote access to the drive's internal diagnostic registers, allowing maintenance personnel to troubleshoot performance issues or perform firmware updates via a standard network connection.

Technical Specifications

Feature Specification
Model E94AYCER
Brand Lenze
Range 9400-series
Type Ethernet Extension Module
Weight 0.18 kg
Dimensions 14.90 x 7.40 x 6.90 cm
Commodity Code 85049090
Operational Status Active

Frequently Asked Questions

Is the E94AYCER compatible with all 9400-series servo drives?

Yes, the E94AYCER is designed for the 9400-series architecture. However, always ensure your drive's firmware is compatible with the latest version of the Ethernet communication module to avoid connection errors or protocol mismatch.

Does this module require specific cabling for installation?

You should use high-quality, shielded Ethernet (RJ45) cabling (typically Category 5e or 6) designed for industrial environments to prevent signal attenuation or packet loss due to electromagnetic interference (EMI) near motor cables.

Can this module be used for real-time motion control (e.g., EtherCAT)?

The E94AYCER is an Ethernet extension module. While it handles standard Ethernet connectivity, verify the specific version of the module against your required protocol (e.g., Profinet, EtherNet/IP, or EtherCAT) as these are often protocol-specific variants.

Engineering Integration and Operational Protocols

  • Shielding and Routing: When installing the module, ensure Ethernet cables are routed in separate cable trays away from high-power motor leads or AC power lines. Inductive interference from high-power cables can degrade network performance and lead to intermittent drive communication timeouts.
  • Installation Steps: Power down the servo drive entirely before attempting to install or remove the communication module. Align the module’s pins with the drive’s communication slot and press firmly until the locking mechanism engages. Ensure the module is seated squarely to prevent pin damage.
  • Network Addressing: Once installed, assign a unique IP address to the module within your automation network. Using a static IP address is recommended to prevent addressing conflicts that could arise if a DHCP server dynamically reassigns addresses.
  • Commissioning: Use the Lenze configuration software to define the module's role within the network. Perform a communication test between the PLC and the drive to confirm that heartbeat signals and process data are exchanging correctly before enabling the servo motor for full-load operation.
Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 8
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
White Greyish White Silver
Country of origin
Germany

Technical knowledge

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.