Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks
Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.
Manufacturer: Lenze
Product No.: EVS9329-ESV004
Country of origin:Germany
Product Type: Servo drives
Barcode: 85044095
Payment: T/T, Western Union
Weight: 12500g
Dimensions: 35,00cm x 25,00cm x 25,00cm
Shipping port: Xiamen
Warranty: 12 months
The Lenze EVS9329-ESV004 (EVS9329-ESV004) is a high-capacity servo inverter from the 9300-Series, engineered for rigorous motion control tasks in large-scale industrial automation. Rated for 30.0 kW, this unit provides the substantial torque and high-dynamic response required for demanding applications such as heavy-duty material handling, large-format printing presses, and multi-axis synchronised machinery. By maintaining tight control over motor speed and position, this inverter mitigates mechanical wear and enhances overall cycle throughput, serving as a cornerstone for reliable, long-term industrial operations.
The EVS9329-ESV004 utilizes the 9300-Series modular platform, allowing for flexible integration into complex control hierarchies.
| Feature | Specification |
| Model | EVS9329-ESV004 |
| Brand | Lenze |
| Range | 9300-Series |
| Type | Servo drives |
| Power Rating | 30.0 kW |
| Weight | 12.50 kg |
| Dimensions | 35.00 x 25.00 x 25.00 cm |
| Enclosure Rating | IP20 |
| Origin | Germany |
Is the EVS9329-ESV004 compatible with my existing 30.0 kW 9300-Series setup?
Yes, this model is a direct functional replacement within the 9300-Series range. If replacing a failed unit, ensure the firmware version and parameter configuration file (GDC/L-force Engineer) are accurately mapped to the new drive for seamless integration.
Does this drive require specialized cooling in the control cabinet?
Given the 30.0 kW rating, the drive generates significant thermal energy. You must ensure the cabinet is equipped with adequate forced-air ventilation. Maintain a minimum vertical clearance of 100 mm above and below the drive to prevent derating caused by localized heat buildup.
What precautions are necessary for the DC bus connection in high-power setups?
When sharing DC buses across multiple axes, ensure proper fusing for each drive and verify that the collective regenerative energy can be managed by your braking resistor or regenerative power supply module to prevent bus overvoltage faults.