Lenze

Lenze I55AE137B10V10000S i550 Series AC Inverter Drive

SKU I55AE137B10V10000S

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Lenze

  • Product No.: I55AE137B10V10000S

  • Country of origin:Germany

  • Product Type: AC Inverter Drives

  • Barcode: 85371091

  • Payment: T/T, Western Union

  • Weight: 800g

  • Dimensions: 6.0 cm x 21.4 cm x 13.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Engineered for space-restricted control cabinets, the Lenze I55AE137B10V10000S frequency inverter delivers precise speed and torque regulation for low-power motor systems. This compact drive converts single-phase 230V mains power into a variable-frequency three-phase output, making it highly suitable for running small three-phase AC motors from standard single-phase utility grids. As part of the reliable Lenze i550 series, this unit features a slim profile and high energy efficiency, minimizing thermal load inside industrial enclosures.

Key Features

  • Phase Conversion: Efficiently converts 1-phase 230 VAC input to 3-phase 230 VAC output for standard industrial motors.
  • Compact Footprint: Slim design allows side-by-side mounting in control panels, optimizing cabinet space.
  • IP20 Protection: Designed for clean, dry industrial environments with standard finger-safe terminal connections.
  • Scalable Integration: Fully compatible with the modular Lenze i500 range of communication and interface options.

Applications

  • Conveyor Systems: Precise speed control for small-scale material handling and packaging lines.
  • Pumps and Fans: Energy-efficient flow regulation in commercial HVAC and fluid transfer systems.
  • Machine Tooling: Spindle and auxiliary axis control in light-duty manufacturing machinery.

Technical Specifications

Parameter Value
Manufacturer Lenze
Model Number I55AE137B10V10000S
Series i550 Series
Rated Power 0.37 kW (0.5 HP)
Input Voltage 230 VAC (1-Phase)
Output Voltage 230 VAC (3-Phase)
Enclosure Protection Rating IP20
Dimensions (W x H x D) 6.0 cm x 21.4 cm x 13.0 cm
Weight 0.80 kg
Country of Origin Germany
Commodity Code 85371091

Empirical Engineering Insights

Alternative Models & Compatibility

The i550 series serves as the modern, high-efficiency replacement for legacy Lenze 8200 vector series drives. When migrating older systems to the i550 platform, parameter sets must be converted using the Lenze Easy Starter software tool, as direct parameter file transfers are not supported due to differences in firmware architecture.

Application Pitfalls & Engineering Notes

Because this unit is IP20 rated, it relies heavily on convective airflow for cooling. In enclosed control panels, maintain a minimum clearance of 50 mm above and below the drive. Failure to provide adequate clearance under continuous 0.37 kW loads can lead to premature thermal tripping or overtemperature faults (Fault Code 0x2310).

Commissioning & Wiring Tips

Always ground the motor cable shield directly to the metal mounting plate using low-impedance EMC shield clamps. This prevents high-frequency common-mode currents from leaking into nearby sensor wiring, which can cause intermittent signal corruption on analog feedback loops.

Installation Guidelines

CRITICAL WARNING: Ensure all incoming AC power sources are completely de-energized and locked out before attempting installation or wiring. Wait at least 5 minutes after disconnecting power to allow the internal DC-bus capacitors to fully discharge to safe voltage levels.
1
Mount the drive vertically on a flat, vibration-free metal backplate inside a clean, dust-free enclosure.
2
Connect the single-phase 230 VAC mains supply to the L1 and N input terminals, ensuring proper protective earth (PE) grounding.
3
Wire the three-phase motor leads to the U, V, and W output terminals using shielded motor cable.
4
Verify all terminal screw torques conform to Lenze specifications before energizing the unit for commissioning.

FAQ

What is the input phase requirement for this drive?

This drive accepts a single-phase 230 VAC input and outputs a three-phase 230 VAC supply to the motor.

Can I use this drive in a washdown environment?

No, this unit has an IP20 protection rating and must be installed inside a suitable NEMA or IP-rated enclosure to protect it from moisture and conductive dust.

What software is used to configure this inverter?

Configuration and parameter backup are performed using the Lenze Easy Starter software platform via a compatible interface module.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 6
Only 6 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Designing H-Bridge Motor Drives Without Shoot-Through

A practical guide to H-bridge motor drives covering switching states, dead time, inductive current paths, PWM choices, protection, PCB layout, PLC interfacing, and staged commissioning tests.

Designing Mitsubishi FX PLC Sequences with STL and RET

Learn how Mitsubishi FX PLC STL and RET instructions structure conveyor and pneumatic sequences, with practical state design, transition logic, timeouts, diagnostics, and safe restart boundaries.

Selecting and Troubleshooting DIN Valve Connectors

A practical guide to selecting, wiring and diagnosing DIN-style valve connectors, including form identification, coil voltage, suppression, polarity, sealing, release-time effects and commissioning...

PLC or Microcontroller for Arc-Welding Motion Control?

A PLC and a microcontroller can both generate step-and-direction motion, but arc welding exposes major differences in EMC, I/O protection, diagnostics, maintainability, safety integration, and...

Piezo Pneumatic Valves: Precision, Power, and Design Limits

Piezo pneumatic valves offer low holding power and fine proportional control, but they are not universal solenoid replacements. This guide covers driver electronics, flow limits, contamination, fail...

Sensor Timer Functions: When Local Delay Helps PLC Logic

Built-in sensor timers can reject chatter, stretch short pulses, and simplify local timing—but they do not replace PLC diagnostics or safety logic. Learn how to apply on-delay, off-delay, and...