Implementing 3-Switch XOR Ladder Logic with Internal Bit
Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.
Processing high-precision industrial signals within CC-Link network architectures, the AJ65VBTCU-68DAVN functions as a high-density digital-to-analog interface module. This remote device station converts digital inputs from the host controller into analog voltage signals across 8 independent channels. Engineered for installation within control panels, it delivers precise analog references to drive speed controllers, control valves, and actuator systems.
The AJ65VBTCU-68DAVN utilizes high-performance D/A conversion circuitry to complete signal processing at a rate of 1 ms per channel. The electrical design isolates communication lines and analog outputs through photocouplers, while the internal power supply system and analog circuits are isolated via transformer barriers. This high-isolation framework prevents ground loops and safeguards against industrial noise and transient surges in challenging electromagnetic environments.
| Administrative | Manufacturer | Mitsubishi Electric |
| Model / Part Number | AJ65VBTCU-68DAVN | |
| Product Type | CC-Link Digital-Analog Conversion Unit | |
| Output Characteristics | Analog Channels | 8 outputs (8 channels) |
| Output Voltage Range | DC -10 to +10 V (External load: 2 kOhm to 1 MOhm) | |
| Digital Input Range | -4096 to +4095 | |
| D/A Conversion Speed | 1 ms / channel | |
| Absolute Maximum Output | +/- 12 V | |
| Resolution & Accuracy | Voltage Output 0 to 5 V | 0 to 4000 (Resolution: 1.25 mV) |
| Voltage Output -10 to 10 V | -4000 to 4000 (Resolution: 2.5 mV) | |
| Accuracy (Relative to Max Value) | +/- 0.2% (at 25 +/- 5 degC); +/- 0.3% (at 0 to 55 degC) | |
| Electrical & Power | Unit Power Supply Voltage | DC 24 V (Allowable range: DC 20.4 to 26.4 V, ripple within 5%) |
| Current Consumption | 0.15 A (at 24 VDC) | |
| Inrush Current | 4.3 A, 1.2 ms or less | |
| Isolation & Protection | Circuit Isolation Method | Photocoupler isolation (Communication and analog output); Transformer isolation (Power supply and analog output); Non-isolated between output channels |
| Withstand Voltage | 500 V AC for 1 minute (Between power supply/communication block and analog outputs) | |
| Output Protection | Short-circuit protection included | |
| Network Parameters | Station Type | Remote device station (Ver.1 or Ver.2 remote device station) |
| Occupied Stations | Ver.1: 3 stations; Ver.2: 1 station (Extended cyclic setting: 4 times) | |
| Communication Cable Compatibility | Ver.1.10 compatible CC-Link dedicated cable (e.g., FANC-110SBH, FA-CBL200PSBH, CS-110) | |
| External Connections | One-touch connectors for communication, power/FG, and I/O (sold separately) | |
| Mechanical & Environmental | Dimensions (H x W x D) | 115 mm x 41 mm x 67 mm |
| Weight / Shipping Weight | 0.16 kg / 1.0 kg | |
| Operating Ambient Temperature | 0 to 55 degC (Storage: -20 to 75 degC) | |
| Protection Rating | IP1XB |
Global Express Shipping
Returns & Warranty

Processing high-precision industrial signals within CC-Link network architectures, the AJ65VBTCU-68DAVN functions as a high-density digital-to-analog interface module. This remote device station converts digital inputs from the host controller into analog voltage signals across 8 independent channels. Engineered for installation within control panels, it delivers precise analog references to drive speed controllers, control valves, and actuator systems.
The AJ65VBTCU-68DAVN utilizes high-performance D/A conversion circuitry to complete signal processing at a rate of 1 ms per channel. The electrical design isolates communication lines and analog outputs through photocouplers, while the internal power supply system and analog circuits are isolated via transformer barriers. This high-isolation framework prevents ground loops and safeguards against industrial noise and transient surges in challenging electromagnetic environments.
| Administrative | Manufacturer | Mitsubishi Electric |
| Model / Part Number | AJ65VBTCU-68DAVN | |
| Product Type | CC-Link Digital-Analog Conversion Unit | |
| Output Characteristics | Analog Channels | 8 outputs (8 channels) |
| Output Voltage Range | DC -10 to +10 V (External load: 2 kOhm to 1 MOhm) | |
| Digital Input Range | -4096 to +4095 | |
| D/A Conversion Speed | 1 ms / channel | |
| Absolute Maximum Output | +/- 12 V | |
| Resolution & Accuracy | Voltage Output 0 to 5 V | 0 to 4000 (Resolution: 1.25 mV) |
| Voltage Output -10 to 10 V | -4000 to 4000 (Resolution: 2.5 mV) | |
| Accuracy (Relative to Max Value) | +/- 0.2% (at 25 +/- 5 degC); +/- 0.3% (at 0 to 55 degC) | |
| Electrical & Power | Unit Power Supply Voltage | DC 24 V (Allowable range: DC 20.4 to 26.4 V, ripple within 5%) |
| Current Consumption | 0.15 A (at 24 VDC) | |
| Inrush Current | 4.3 A, 1.2 ms or less | |
| Isolation & Protection | Circuit Isolation Method | Photocoupler isolation (Communication and analog output); Transformer isolation (Power supply and analog output); Non-isolated between output channels |
| Withstand Voltage | 500 V AC for 1 minute (Between power supply/communication block and analog outputs) | |
| Output Protection | Short-circuit protection included | |
| Network Parameters | Station Type | Remote device station (Ver.1 or Ver.2 remote device station) |
| Occupied Stations | Ver.1: 3 stations; Ver.2: 1 station (Extended cyclic setting: 4 times) | |
| Communication Cable Compatibility | Ver.1.10 compatible CC-Link dedicated cable (e.g., FANC-110SBH, FA-CBL200PSBH, CS-110) | |
| External Connections | One-touch connectors for communication, power/FG, and I/O (sold separately) | |
| Mechanical & Environmental | Dimensions (H x W x D) | 115 mm x 41 mm x 67 mm |
| Weight / Shipping Weight | 0.16 kg / 1.0 kg | |
| Operating Ambient Temperature | 0 to 55 degC (Storage: -20 to 75 degC) | |
| Protection Rating | IP1XB |
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
United States
|