Mitsubishi Electric

Mitsubishi Electric FR-A740-0.75K FR-A700 Frequency Inverter Drive

SKU FR-A740-0.75K

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-A740-0.75K

  • Country of origin:United States

  • Product Type: Frequency Inverter Drives

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Designed for precise variable speed control, the FR-A740-0.75K is a high-performance three-phase frequency inverter module within the Mitsubishi Electric FR-A700 series. This drive provides exceptional speed and torque accuracy for low-power industrial machinery, incorporating sensorless vector control technology to deliver reliable performance even at minimal operating speeds.

The unit features built-in PLC functions, allowing users to configure customized control sequences directly on the drive without additional external hardware. Operating on a three-phase supply voltage from 380 to 480 V AC, this compact frequency inverter maintains stable output current ratings and handles momentary overloads smoothly, making it highly compatible with modern automated factory setups and distributed control systems.

Features

  • Real Sensorless Vector Control (RSV) delivers high torque output at low speeds.
  • Integrated mini-PLC capabilities for standalone application configuration.
  • Built-in USB interface for simple diagnostics, parameter tuning, and PC software connection.
  • Advanced energy-saving algorithms optimize motor performance based on actual load dynamics.
  • Robust overload handling limits damage during transient current spikes.
  • Long-life cooling fans and capacitors designed for extended service intervals.

Applications

  • Conveyor belts and automated material handling lines.
  • Packaging, labeling, and sorting machines.
  • Industrial fan, blower, and small-scale pump operations.
  • Machine tool spindles and textile production machinery.

Technical Specifications

Manufacturer Mitsubishi Electric
Model / Part Number FR-A740-0.75K
Series FR-A700
Applicable Motor Capacity 0.75 kW
Rated Output Capacity 1.8 kVA
Rated Output Current 2.3 A
Power Supply Rated Voltage Three-phase 380 to 480 V AC, 50Hz / 60Hz
Permissible AC Voltage Fluctuation 323 to 528 V AC
Permissible Frequency Fluctuation +/-5%
Overload Current Rating 150% for 60 seconds, 200% for 3 seconds (at surrounding air temperature of 50 degC)
Protective Structure Enclosed type (IP20)
Cooling Method Natural convection / self-cooling

Installation Guidelines

  • Mount the inverter vertically inside a protective electrical enclosure to prevent contamination.
  • Maintain a minimum clearance of 50 mm on both sides and 100 mm top and bottom for proper airflow.
  • Utilize shielded cables for motor connections to comply with electromagnetic compatibility (EMC) regulations.
  • Ensure the ground terminal is securely connected to a dedicated industrial earth ground.

Compliance and Certifications

  • CE Marked
  • UL Listed
  • cUL Listed

FAQ

What is the rated capacity of the Mitsubishi FR-A740-0.75K?

The FR-A740-0.75K inverter is rated for an applicable motor capacity of 0.75 kW with a rated output current of 2.3 A.

What power supply range does the FR-A740-0.75K support?

The drive accepts a three-phase input voltage range from 380 to 480 V AC at 50/60Hz, with a permissible voltage fluctuation range of 323 to 528 V AC.

What is the IP rating of this frequency inverter?

The FR-A740-0.75K features an IP20 protective structure, requiring installation inside a suitable electrical control cabinet.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.