What Is SCADA? Supervisory Control Without Replacing the PLC
SCADA sits above PLCs and RTUs: it acquires field data, alarms operators, and issues supervisory commands across plants and remote assets—without replacing local deterministic control.

Providing high-performance vector control for heavy-duty industrial applications, the Mitsubishi Electric FR-A740-15K frequency inverter delivers precise motor regulation across demanding operational profiles. This variable frequency drive (VFD) from the FR-A700 Series is engineered for complex systems requiring high torque, exceptional speed accuracy, and advanced motor control dynamics. Operating on a 400V class three-phase input, it handles a nominal motor output of 15 kW, making it a reliable component in heavy machinery, extrusion lines, cranes, and continuous manufacturing systems.
Equipped with Real Sensorless Vector (RSV) control and advanced vector control algorithms, the drive achieves outstanding speed and torque performance without requiring encoder feedback. The integrated PLC functionality allows users to customize control sequences directly within the inverter, reducing external hardware overhead and simplifying system integration.
| Parameter | Value / Specification |
|---|---|
| Manufacturer | Mitsubishi Electric |
| Model Number | FR-A740-15K |
| Inverter Series | FR-A700 |
| Voltage Class | 400V Class (Three-Phase 380 to 480 VAC, 50/60 Hz) |
| Permissible AC Voltage Fluctuation | 323 to 528 VAC (50Hz/60Hz) |
| Applicable Motor Capacity | 15 kW |
| Rated Output Current | 31 A |
| Overload Current Rating | 150% 60 seconds, 200% 3 seconds (at ambient temperature of 50 degC) |
| Cooling Method | Forced Air Cooling |
| Enclosure Rating | IP20 (Open Type) |
| Net Weight | 7.5 kg |
| Shipping Weight (Calculated) | 9.0 kg |
| Terminal Group | Functional Assignment |
|---|---|
| R/L1, S/L2, T/L3 | Main 3-phase AC power supply input terminals. |
| U, V, W | 3-phase AC output connections to the induction motor. |
| P/+, PR | Connection terminal for optional external brake resistor. |
| STF / STR | Forward rotation start / Reverse rotation start control terminals. |
| 10, 2, 5 | Analog input terminals (0 to 10 VDC, 4 to 20 mA) for external frequency references. |
When migrating or sourcing drop-in replacements, note that the FR-A740-15K shares functional equivalents within the newer FR-A840-00380-E2-60 (A800 series). Parameter transfer from the A700 to the A800 series can be automated via the FR Configurator2 software. However, verify terminal assignment modifications, as the control terminal blocks differ in wiring entry formats (screw terminals on the A700 vs. spring clamp terminals on the A800).
If operating in high ambient conditions (above 40 degC), the carrier frequency should be adjusted downward (Parameter 72) to prevent premature thermal overcurrent faults (E.THT). Avoid continuous operation below 6 Hz without supplementary external motor cooling fan kits, as standard self-cooled motors will experience severe thermal degradation at reduced speeds due to diminished internal fan velocity.
Always ensure that Parameter 9 (Electronic Thermal O/L Relay) is set to match the nameplate current of the connected motor; the factory default corresponds to the maximum rating of the VFD and may fail to protect smaller motors. Install control signals using shielded twisted-pair cables with the shield grounded only at the drive end (Terminal 5) to mitigate electromagnetic interference in analog circuits.
Isolate all input AC power before performing any terminal modifications or inspection routines. Wait a minimum of 10 minutes after physical power disconnection for the internal DC-bus capacitors to fully discharge. Verify that the DC-bus voltage between terminals P/+ and N/- is below 45 VDC using a calibrated digital multimeter before proceeding with touch operations.
Mount the inverter vertically inside an IP54 enclosure if the environment is dusty or humid, ensuring a minimum clearance of 10 cm above and below the unit for unobstructed heat dissipation.
Ensure the physical ground connection meets standard industrial safety requirements (Earth resistance under 10 ohms). Use a thick copper protective conductor connected to the drive's PE terminal.
Confirm that power cable routing is physically separated from control and encoder feedback signaling paths to minimize capacitive coupling noise.
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
United States
|