Mitsubishi Electric

Mitsubishi Electric FX2N-16MR-DS FX2N Series Base Unit

SKU FX2N-16MR-DS

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Mitsubishi Electric

  • Product No.: FX2N-16MR-DS

  • Country of origin:United States

  • Product Type: PLC Base Units

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 13cm x 9cm x 8.7cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Integrated control and high-speed processing define the FX2N-16MR-DS, a compact base unit belonging to the renowned FX2N series of programmable logic controllers. Engineered for robust execution in heavy-duty environments, this controller features 8 digital inputs and 8 relay outputs, managed within a space-saving chassis. Operating on a 24V DC power supply, it offers an efficient architecture for localized machine automation and decentralized control tasks. The unit serves as the processing foundation, allowing seamless integration with auxiliary expansion blocks and specialized communication modules to scale overall system capacity as needed.

Features

  • Equipped with 8 digital inputs (24V DC, sink/source selectable) and 8 relay outputs for versatile load switching.
  • Powered via 24V DC, suitable for mobile applications, control panels, and field-mounted enclosures.
  • Expandable bus connection allows the integration of additional digital, analog, and communication expansion blocks.
  • Integrated run/stop switch on the front panel for simplified testing and local maintenance.
  • High-speed processing capability suitable for real-time logic execution, sequencing, and timing tasks.
  • Removable terminal blocks facilitate direct, secure wiring and rapid module replacement.

Applications

  • Pumping stations and automated water treatment systems.
  • Conveyor networks, sorting systems, and material handling lines.
  • HVAC control systems and building automation distribution panels.
  • Packaging, labeling, and small-scale assembly machinery.

Technical Specifications

ParameterSpecification
Manufacturer Mitsubishi Electric
Model / Part Number FX2N-16MR-DS
Series FX2N Series
Product Type PLC Base Unit
Power Supply Voltage 24V DC
Allowable Power Range 20.4V DC to 26.4V DC
Number of Integrated Inputs 8 Inputs
Input Type 24V DC (Sink / Source)
Number of Integrated Outputs 8 Outputs
Output Type Relay
Max. Switching Voltage 250V AC / 30V DC
Response Time Approx. 10 ms (Relay response)
Mounting Type 35mm DIN Rail or Direct Screw Mounting
Ambient Operating Temperature 0 to 55 degC
Storage Temperature -20 to 70 degC

Connections and Interfaces

Terminal LabelFunction / Assignment
24V / 0V 24V DC Power Input Terminals
FG Frame Ground / Protective Earth
X0 - X7 DC Digital Input Channels (0 to 7)
COM (Inputs) Common Terminal for Input Wiring
Y0 - Y7 Relay Output Channels (0 to 7)
COM0 - COM2 Common Terminals for Relay Output Groups

Installation Guidelines

  • Mounting: Attach securely to a standard 35mm DIN rail or screw directly to an earthed backplane panel. Keep a minimum spacing of 50mm on all sides for passive cooling and terminal access.
  • Grounding: Connect the FG (Frame Ground) terminal to a dedicated, low-impedance functional ground (Class D grounding, 100 ohms or less) to minimize electromagnetic interference.
  • Wiring: Route high-voltage AC output wires separate from low-voltage DC input and communication signal cables to avoid signal crosstalk. Use crimp terminals matching the M3 terminal screws.

FAQ

What is the power supply requirement for the FX2N-16MR-DS?

The FX2N-16MR-DS operates on a nominal 24V DC power supply, with an allowable operational range of 20.4V DC to 26.4V DC.

What type of outputs are available on this unit?

This PLC base unit features 8 electromagnetic relay outputs, capable of switching both AC and DC loads up to a maximum of 250V AC or 30V DC.

Can the I/O capacity of the FX2N-16MR-DS be expanded?

Yes, the FX2N-16MR-DS can be expanded by connecting standard FX series digital, analog, and specialized communication expansion blocks.

What range of ambient temperatures can the module withstand during operation?

The module is rated for safe operation in ambient temperatures ranging from 0 to 55 degC.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.