Mitsubishi Electric

Mitsubishi Electric FX3UC-32MT-LT-2 FX3UC Programmable Controller

SKU FX3UC-32MT-LT-2

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Mitsubishi Electric

  • Product No.: FX3UC-32MT-LT-2

  • Country of origin:United States

  • Product Type: Programmable Logic Controllers

  • Payment: T/T, Western Union

  • Weight: 250g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Engineered for high-density control cabinet environments, the FX3UC-32MT-LT-2 is a compact, high-performance programmable logic controller (PLC) main unit from the Mitsubishi Electric FX3UC series. This controller integrates 32 built-in I/O points, consisting of 16 DC inputs and 16 transistor sink outputs, making it highly suitable for high-speed switching and precise machine control. A key feature of this model is its integrated CC-Link/LT master interface, which enables direct connection to decentralized sensor and actuator networks without the need for additional communication modules. Its slim, connector-type design significantly reduces installation space while maintaining the advanced processing speeds and instruction sets of the FX3 family.

Features

  • Ultra-compact form factor designed to minimize control panel footprint.
  • Integrated CC-Link/LT master function for simplified, cost-effective field network deployment.
  • High-speed program execution and advanced instruction processing capabilities.
  • 32 integrated I/O points (16 inputs and 16 transistor sink outputs) utilizing space-saving ribbon connectors.
  • Expandable architecture compatible with FX-series extension blocks and special function modules.

Applications

  • Material handling and automated conveyor systems.
  • Packaging, labeling, and wrapping machinery.
  • Decentralized machine-level control networks.
  • Automated assembly lines and pick-and-place systems.

Technical Specifications

Manufacturer Mitsubishi Electric
Part Number / Model FX3UC-32MT-LT-2
Series FX3UC
Product Type Programmable Controller (Main Unit)
Total Integrated I/O 32 points
Input Points 16 points (DC inputs)
Output Points 16 points (Transistor sink outputs)
Built-in Network Interface CC-Link/LT Master
Operating Ambient Temperature 0 to 55 degC (32 to 131 degF)
Storage Ambient Temperature -25 to 75 degC (-13 to 167 degF)
Operating Ambient Humidity 5 to 95% RH (non-condensing)
Shock Resistance 147 m/s² acceleration, 11ms action time, 3 times by half-sine pulse in X, Y, and Z directions
Noise Resistance 1,000 Vp-p noise voltage, 1 us noise width, 1 ns rise time, 30 to 100 Hz period (via noise simulator)
Grounding Class D grounding (grounding resistance of 100 ohms or less)
Working Atmosphere Free from corrosive/flammable gases and excessive conductive dust
Working Altitude Less than 2000 meters
Weight Approx. 0.25 kg

Installation Guidelines

  • Mounting: Install the unit on a standard 35mm DIN rail within an enclosed, dust-free control cabinet.
  • Grounding: Ensure Class D grounding is established with a dedicated grounding wire. Grounding resistance must be 100 ohms or less.
  • Wiring: Use appropriate connector cables for the high-density I/O terminals to prevent loose connections and signal interference.
  • Ventilation: Maintain adequate clearance above and below the unit to ensure natural convection cooling and prevent thermal buildup.

FAQ

What is the main advantage of the FX3UC-32MT-LT-2 controller?

The FX3UC-32MT-LT-2 features an ultra-compact design with a built-in CC-Link/LT master interface, allowing direct connection to decentralized I/O networks without requiring an external master module.

What type of outputs does this PLC use?

This unit is equipped with 16 transistor sink outputs, which are ideal for high-speed switching applications.

What are the grounding requirements for the FX3UC-32MT-LT-2?

It requires Class D grounding with a grounding resistance of 100 ohms or less to ensure stable operation and noise immunity.

What is the operating temperature range for this programmable controller?

The operating ambient temperature range is 0 to 55 degC (32 to 131 degF).

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.