Mitsubishi Electric

Mitsubishi Electric FX5-C32EX/DS MELSEC iQ-F Series Extension Input Module

SKU FX5-C32EX/DS

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Mitsubishi Electric
  • Product No.: FX5-C32EX/DS
  • Origin United States
  • Product Type: Extension Modules
  • Payment: T/T, Western Union
  • Weight: 1.5 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

Designed to scale the digital input capacity of compact industrial control systems, the FX5-C32EX/DS serves as a high-density digital input extension module for the Mitsubishi Electric MELSEC iQ-F series PLC. This expansion unit interfaces seamlessly via a space-saving connector-type hookup, offering 32 dedicated discrete input channels. By utilizing a compact block format with connector wiring, it optimizes electrical cabinet space while simplifying high-point-count field-wiring architectures.

Features

  • Provides 32 discrete digital input points to extend controller capability.
  • Compatible with the high-performance Mitsubishi Electric MELSEC iQ-F series backplane.
  • Connector-type interface reduces wiring complexity and physical footprint inside the control panel.
  • Low internal current consumption ensures minimal thermal load on the system power supply.
  • Designed for rugged industrial environments with robust electrical isolation.

Applications

  • High-density machinery control panels
  • Factory automation and assembly lines
  • Material handling and conveyor systems
  • Packaging and processing equipment

Technical Specifications

Manufacturer Mitsubishi Electric
Model / Part Number FX5-C32EX/DS
Series MELSEC iQ-F Series
Module Type Extension Input Module (Connector Type)
Total Input/Output Points 32 points
Input Points 32 points
Output Points 0 points
Input Type 24 V DC (sink)
Connection Type Connector
Internal 5 V DC Power Consumption 120 mA
Internal 24 V DC Power Consumption 130 mA
Shipping Weight 1.5 kg

Installation Guidelines

  • Always disconnect all external power sources before mounting or wiring the extension module to prevent electrical shock or equipment damage.
  • Mount the module securely on a standard 35 mm DIN rail or directly to the panel using appropriate mounting brackets.
  • Ensure adequate ventilation clearance around the module as specified in the MELSEC iQ-F hardware manual.
  • Use designated mating connectors and proper crimping tools to ensure secure field wire connections.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the FX5-C32EX/DS module?
The FX5-C32EX/DS is a 32-point digital input extension module designed to expand the input capacity of Mitsubishi Electric MELSEC iQ-F series PLC systems using a compact connector interface.
What is the input rating and logic configuration of this extension module?
It features 32 inputs rated at 24 V DC configured for sink input operations.
What are the internal power supply requirements for the FX5-C32EX/DS?
The module consumes 120 mA from the internal 5 V DC power supply and 130 mA from the 24 V DC power supply provided via the PLC expansion bus.
Does this module include traditional screw terminals?
No, this module utilizes high-density connector-type interfaces instead of traditional screw terminal blocks to minimize panel space.
Reviews

FX5-C32EX/DS

Stock & lead time on request

Call
1 of 1

Mitsubishi Electric FX5-C32EX/DS MELSEC iQ-F Series Extension Input Module

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FX5-C32EX/DS

  • Country of origin:United States

  • Product Type: Extension Modules

  • Payment: T/T, Western Union

  • Weight: 1500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed to scale the digital input capacity of compact industrial control systems, the FX5-C32EX/DS serves as a high-density digital input extension module for the Mitsubishi Electric MELSEC iQ-F series PLC. This expansion unit interfaces seamlessly via a space-saving connector-type hookup, offering 32 dedicated discrete input channels. By utilizing a compact block format with connector wiring, it optimizes electrical cabinet space while simplifying high-point-count field-wiring architectures.

Features

  • Provides 32 discrete digital input points to extend controller capability.
  • Compatible with the high-performance Mitsubishi Electric MELSEC iQ-F series backplane.
  • Connector-type interface reduces wiring complexity and physical footprint inside the control panel.
  • Low internal current consumption ensures minimal thermal load on the system power supply.
  • Designed for rugged industrial environments with robust electrical isolation.

Applications

  • High-density machinery control panels
  • Factory automation and assembly lines
  • Material handling and conveyor systems
  • Packaging and processing equipment

Technical Specifications

Manufacturer Mitsubishi Electric
Model / Part Number FX5-C32EX/DS
Series MELSEC iQ-F Series
Module Type Extension Input Module (Connector Type)
Total Input/Output Points 32 points
Input Points 32 points
Output Points 0 points
Input Type 24 V DC (sink)
Connection Type Connector
Internal 5 V DC Power Consumption 120 mA
Internal 24 V DC Power Consumption 130 mA
Shipping Weight 1.5 kg

Installation Guidelines

  • Always disconnect all external power sources before mounting or wiring the extension module to prevent electrical shock or equipment damage.
  • Mount the module securely on a standard 35 mm DIN rail or directly to the panel using appropriate mounting brackets.
  • Ensure adequate ventilation clearance around the module as specified in the MELSEC iQ-F hardware manual.
  • Use designated mating connectors and proper crimping tools to ensure secure field wire connections.

What is the primary function of the FX5-C32EX/DS module?

The FX5-C32EX/DS is a 32-point digital input extension module designed to expand the input capacity of Mitsubishi Electric MELSEC iQ-F series PLC systems using a compact connector interface.

What is the input rating and logic configuration of this extension module?

It features 32 inputs rated at 24 V DC configured for sink input operations.

What are the internal power supply requirements for the FX5-C32EX/DS?

The module consumes 120 mA from the internal 5 V DC power supply and 130 mA from the 24 V DC power supply provided via the PLC expansion bus.

Does this module include traditional screw terminals?

No, this module utilizes high-density connector-type interfaces instead of traditional screw terminal blocks to minimize panel space.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...