Mitsubishi Electric

Mitsubishi Electric GT1275-VNBA GOT1000 Touch Screen HMI

SKU GT1275-VNBA

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Mitsubishi Electric

  • Product No.: GT1275-VNBA

  • Country of origin:United States

  • Product Type: Touch Screen HMIs

  • Payment: T/T, Western Union

  • Weight: 2300g

  • Dimensions: 340 mm x 280 mm x 125 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Facilitating high-resolution plant-floor visualization, the Mitsubishi Electric GT1275-VNBA functions as an industrial operator interface within the GOT1000 platform. This 10.4-inch TFT liquid crystal display provides sharp graphical monitoring and robust control capabilities over diverse automated systems. Operating on a universal 100 to 240VAC power supply, the unit integrates essential fieldbus and Ethernet communication options directly onto its main board, making it a reliable choice for monitoring complex industrial machinery and distributed assembly operations.

Features

  • High-Contrast Display: 10.4-inch TFT color LCD screen displaying 256 colors with a clear 640 x 480 pixel VGA resolution.
  • Versatile Power Compatibility: Accepts wide-range AC input from 100 to 240VAC (50/60Hz) to simplify integration across global regional grids.
  • Multi-Port Connectivity: Built-in Ethernet, RS-422/485, and RS-232 interfaces accommodate simultaneous multi-channel controller communication.
  • Data Management: Integrated SD memory card slot and USB port permit rapid project transfer, logging, and OS backups.
  • Industrial Durability: Front-panel rating matching IP67F environmental standards provides protection against dust, water ingress, and oil spray.

Applications

  • Automotive assembly and robotic workcell control panels.
  • Water and wastewater treatment plant visualization interfaces.
  • Packaging, food processing, and material handling machinery.
  • Distributed PLC network monitoring in central control rooms.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Number GT1275-VNBA
Series GOT1000 (GT12 Series)
Display Technology TFT Color LCD
Screen Size 10.4 inches (diagonal)
Resolution 640 x 480 pixels (VGA)
Display Colors 256 colors
Input Power Supply 100 to 240VAC (+10%, -15%)
Frequency Rating 50 / 60 Hz (+/-5%)
Power Consumption 41VA or less (at maximum load)
Inrush Current 40A or less (for 4 ms at max load)
Touch Panel Type Analog resistive
Operating Temperature 0 to 50 degC
Protection Rating IP67F (front face when panel-mounted)
Net Hardware Weight 2.3 kg (5.07 lbs)
Shipping Weight (Calculated) 3.5 kg
Package Dimensions (Calculated) 340 mm x 280 mm x 125 mm

Connections and Interfaces

Interface / Connector Function / Circuit Assignment
Ethernet (RJ45) 10BASE-T/100BASE-TX interface for high-speed PLC data link and diagnostic network configurations
RS-422/485 (D-Sub 9-Pin Female) Direct connection to FX series, Q series, or third-party serial controllers and microcontrollers
RS-232 (D-Sub 9-Pin Male) Connection port for bar code readers, personal computers, or specialized serial hardware
USB Mini-B (Device) Dedicated PC transfer interface for application screen creation and testing via GT Works3
USB Type A (Host) External storage connection for memory drives to record trends, transfer boot parameters, or load projects
SD Card Slot Expansion storage accepting SD/SDHC media card for immediate local program backups and historical logging

Alternative Models & Compatibility

The GT1275-VNBA serves as an excellent upgrade path for older GT1175 series devices. While sharing similar panel cutout dimensions, the GT1275 integrates built-in Ethernet, removing the need for auxiliary serial-to-Ethernet converters. Upgrading projects from legacy software tools is fully supported inside GT Designer3, ensuring low-risk software migration.

Application Pitfalls & Engineering Notes

To prevent thermal throttling and maintain display longevity, avoid installing the HMI in direct sunlight or within high-temperature enclosures exceeding 50 degC. When mounting inside completely closed panels, provide at least 100 mm of clear space above and below the rear ventilation slots to allow natural convective heat dissipation.

Commissioning & Wiring Tips

Always ensure that the functional ground (FG) terminal on the AC power block is connected using a dedicated ground lead (minimum 2 mm squared wire) directly to a unified machine ground. This reduces local electromagnetic interference (EMI) from neighboring variable frequency drives (VFDs) which can otherwise interfere with the HMI analog touch panel sensitivity.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all upstream electrical power supplies before performing installation, mounting, or terminal wiring. Verify that no residual voltage remains using an electrical tester to prevent severe electrical shock or damage to the unit's internal circuitry.

1

Prepare Panel Cutout

Create a panel cutout matching the standard dimensions of 289 mm x 200 mm, ensuring the panel thickness is between 2.0 mm and 4.0 mm.

2

Check Panel Gasket

Verify that the rubber water-resistant gasket is securely seated in its channel around the back bezel of the HMI unit prior to insertion.

3

Insert and Secure Mounts

Insert the HMI into the cutout from the front of the panel. Fasten the provided mounting brackets to the rear casing, tightening the screws to a precise torque of 0.36 to 0.48 N.m to ensure a dust-tight, waterproof seal.

4

Connect Power Terminals

Route 100-240VAC power lines through a class-D grounded distribution point. Connect securely to the terminals on the back, and ground the functional ground terminal immediately.

FAQ

Can I download projects to the GT1275-VNBA using Ethernet?

Yes. The HMI features an integrated RJ45 10BASE-T/100BASE-TX port. You can download and upload application projects directly through GT Works3 after configuring the communication settings to match your network subnet.

Does this model support logging data directly to local storage?

Yes, historical alarm data, event logs, and system trends can be configured within the design software to save locally onto an SD memory card or a standard USB flash drive formatted in FAT/FAT32.

What software is used to program the GT1275-VNBA HMI?

This unit is fully programmed and configured using Mitsubishi Electric's standard screen design package, GT Works3 (specifically GT Designer3).

How do I maintain the IP67F front-panel rating during installation?

You must ensure the physical mounting panel surface is flat and unwarped, the rubber gasket is completely seated, and the mounting brackets are tightened uniformly to the recommended torque of 0.36 to 0.48 N.m.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Troubleshooting Industrial Control Cabinets Systematically

A structured control-cabinet troubleshooting method covering safe work, drawings, power paths, branch protection, DC supplies, return circuits, PLC outputs, fault records and repair verification.

Measuring Voltage in Industrial Control Circuits

A practical voltage-testing guide for industrial control panels, covering reference points, meter selection, live-dead-live checks, voltage drop, ghost voltage, stored energy and intermittent faults.

Building a Verifiable Lockout Tagout Procedure

A practical lockout tagout guide covering hazardous-energy identification, isolation, stored-energy control, verification, group work, temporary testing, restoration, inspections and audits.

Designing Compressed-Air Preparation at the Machine

A field guide to point-of-use compressed-air preparation covering filters, regulators, drains, dryers, lubrication, pressure loss, isolation, monitoring, commissioning and leak testing.

Selecting Pneumatic Valve Actuation and Safe States

A practical guide to manual, pilot and solenoid pneumatic valves, covering port functions, monostable and bistable behavior, PLC outputs, safe states, commissioning and fault diagnosis.

Designing Current Shunt Measurements That Stay Accurate

A practical guide to current-shunt measurement covering resistor sizing, high-side and low-side placement, Kelvin sensing, error budgets, thermal effects, protection and commissioning tests.