Engineered for high-availability industrial control applications, the Mitsubishi Electric Q64RP is a redundant power supply module designed specifically for the MELSEC-Q Series PLC platform. This module ensures continuous, uninterrupted system operation by working in a dual-redundant configuration on compatible redundant base units. It converts an AC input voltage into stable 5V DC power to drive the CPUs, I/O modules, and co-processors mounted on the backplane.
The Q64RP is critical for process automation and infrastructure applications where unplanned downtime cannot be tolerated. In a redundant setup, if one power supply module fails, the secondary module seamlessly assumes the full load without interrupting system operation or causing CPU resets. Built-in diagnostic features, including dedicated status LEDs and contact terminal outputs, allow maintenance personnel to quickly identify and replace a faulted module while the control system remains fully energized.
| Parameter | Specification |
|---|---|
| Manufacturer | Mitsubishi Electric |
| Model / Part Number | Q64RP |
| Series | MELSEC-Q Series |
| Module Type | Redundant Power Supply Module |
| Input Voltage Range | 100 to 240 V AC (85 to 264 V AC) |
| Input Frequency | 50 / 60 Hz (+/-5%) |
| Input Apparent Power | 160 VA |
| Output Voltage | 5 V DC |
| Output Current | 8.5 A |
| Overcurrent Protection | 9.3 A or higher |
| Overvoltage Protection | 5.5 to 6.5 V |
| Efficiency | 65% or higher |
| Status Display | POWER LED (Green), ERR LED (Red) |
| Allowable Momentary Power Failure Time | Within 20 ms |
| Operating Temperature | 0 to 55 degC |
| Storage Temperature | -25 to 75 degC |
| Approximate Weight | 0.45 kg |
| Terminal Name | Function / Description |
|---|---|
| L / N | Power input terminals (100 to 240 V AC) |
| LG | Line Ground terminal (half-voltage potential filter ground) |
| FG | Frame Ground terminal (connected to protective earth) |
| ERR | Redundant power supply error output terminals (relay contact output) |