Designed for seamless integration into high-speed automation networks, the NZ2GF2B1N-16D serves as a reliable CC-Link IE Field Network remote digital input block. This module enables efficient data acquisition by interfacing field sensors directly with a centralized controller over industrial Ethernet. Featuring a 16-point digital input capacity, it provides flexible configuration options for positive or negative common wiring schemes, optimizing it for diverse sensor types in modern manufacturing environments.

The physical design of the NZ2GF2B1N-16D highlights operational efficiency and maintenance simplicity. It utilizes a two-piece screw terminal block, allowing maintenance personnel to replace the electronic module without disconnecting the field wiring, thereby minimizing system downtime. Utilizing a highly efficient 1-wire connection scheme, it reduces panel wiring complexity while maintaining high signal integrity and noise immunity under demanding industrial conditions.

Features

  • High-Speed Communication: Designed specifically as a slave station for the high-bandwidth CC-Link IE Field Network.
  • Efficient Field Wiring: 1-wire connection type simplifies layout design and reduces installation labor.
  • Two-Piece Terminal Block: Detachable screw-type connection allows module replacement without disturbing existing wiring.
  • Flexible Input Configuration: Supports both positive common and positive/negative shared common connections.
  • Robust Physical Build: Compact block-type remote module designed for DIN-rail or panel-mount enclosures.

Applications

  • Automotive assembly lines and conveyor systems
  • Water and wastewater processing plants
  • Packaging machinery and material handling equipment
  • General factory automation and multi-axis assembly systems

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model / Part Number NZ2GF2B1N-16D
Module Category CC-Link IE Field Network block-type remote module
Input Type DC Input Module
Number of Input Points 16 points
I/O Specification Positive common, positive common/negative common shared type
External Connection Method Two-piece screw terminal block
Wiring Scheme 1-wire type
Module Version N (Improved version)
Weight 0.31 kg

Installation Guidelines

  • Mounting: Securely mount the module on a standard 35mm DIN rail or directly to an electrical enclosure backplane using appropriate screws.
  • Wiring: Ensure all terminal screws are torqued to the manufacturer-specified values to prevent loose connections or high-resistance contact.
  • Grounding: Connect the protective earth (PE) terminal to the functional ground of the control panel using a low-impedance conductor to ensure optimal noise suppression.
  • Thermal Management: Maintain adequate clearance around the module vents to facilitate natural convection and prevent heat buildup within the enclosure.

Compliance and Certifications

  • CE Compliant
  • UL / cUL Listed
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What network protocol does the NZ2GF2B1N-16D use?
The NZ2GF2B1N-16D is designed for the CC-Link IE Field Network, serving as a remote block-type slave module.
How many input points are supported by this module?
This module features 16 digital DC input points.
What is the benefit of the two-piece screw terminal block?
The two-piece terminal block design allows the unit to be detached and replaced without disconnecting the individual field wires, reducing maintenance downtime.
Does the NZ2GF2B1N-16D support both positive and negative common wiring?
Yes, it supports positive common and positive common/negative common shared type configurations.
Reviews

NZ2GF2B1N-16D

Stock & lead time on request

Call
1 of 1

Mitsubishi Electric NZ2GF2B1N-16D CC-Link IE Field Network DC Input Module

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: NZ2GF2B1N-16D

  • Country of origin:United States

  • Product Type: DC Input Modules

  • Payment: T/T, Western Union

  • Weight: 310g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for seamless integration into high-speed automation networks, the NZ2GF2B1N-16D serves as a reliable CC-Link IE Field Network remote digital input block. This module enables efficient data acquisition by interfacing field sensors directly with a centralized controller over industrial Ethernet. Featuring a 16-point digital input capacity, it provides flexible configuration options for positive or negative common wiring schemes, optimizing it for diverse sensor types in modern manufacturing environments.

The physical design of the NZ2GF2B1N-16D highlights operational efficiency and maintenance simplicity. It utilizes a two-piece screw terminal block, allowing maintenance personnel to replace the electronic module without disconnecting the field wiring, thereby minimizing system downtime. Utilizing a highly efficient 1-wire connection scheme, it reduces panel wiring complexity while maintaining high signal integrity and noise immunity under demanding industrial conditions.

Features

  • High-Speed Communication: Designed specifically as a slave station for the high-bandwidth CC-Link IE Field Network.
  • Efficient Field Wiring: 1-wire connection type simplifies layout design and reduces installation labor.
  • Two-Piece Terminal Block: Detachable screw-type connection allows module replacement without disturbing existing wiring.
  • Flexible Input Configuration: Supports both positive common and positive/negative shared common connections.
  • Robust Physical Build: Compact block-type remote module designed for DIN-rail or panel-mount enclosures.

Applications

  • Automotive assembly lines and conveyor systems
  • Water and wastewater processing plants
  • Packaging machinery and material handling equipment
  • General factory automation and multi-axis assembly systems

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model / Part Number NZ2GF2B1N-16D
Module Category CC-Link IE Field Network block-type remote module
Input Type DC Input Module
Number of Input Points 16 points
I/O Specification Positive common, positive common/negative common shared type
External Connection Method Two-piece screw terminal block
Wiring Scheme 1-wire type
Module Version N (Improved version)
Weight 0.31 kg

Installation Guidelines

  • Mounting: Securely mount the module on a standard 35mm DIN rail or directly to an electrical enclosure backplane using appropriate screws.
  • Wiring: Ensure all terminal screws are torqued to the manufacturer-specified values to prevent loose connections or high-resistance contact.
  • Grounding: Connect the protective earth (PE) terminal to the functional ground of the control panel using a low-impedance conductor to ensure optimal noise suppression.
  • Thermal Management: Maintain adequate clearance around the module vents to facilitate natural convection and prevent heat buildup within the enclosure.

Compliance and Certifications

  • CE Compliant
  • UL / cUL Listed

What network protocol does the NZ2GF2B1N-16D use?

The NZ2GF2B1N-16D is designed for the CC-Link IE Field Network, serving as a remote block-type slave module.

How many input points are supported by this module?

This module features 16 digital DC input points.

What is the benefit of the two-piece screw terminal block?

The two-piece terminal block design allows the unit to be detached and replaced without disconnecting the individual field wires, reducing maintenance downtime.

Does the NZ2GF2B1N-16D support both positive and negative common wiring?

Yes, it supports positive common and positive common/negative common shared type configurations.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...