Description

Engineered for high-precision motion control within the MELSEC-Q PLC environment, the QD75P4N positioning module provides multi-axis control capabilities for complex automation tasks. This module manages up to four independent or interpolated axes, facilitating exact path trajectory and speed control for machinery automation.

Utilizing an open collector pulse train output, the QD75P4N coordinates smoothly with external servo drives and stepping motor amplifiers. It stores up to 600 positioning data points per axis, allowing for sophisticated multi-step operations without overloading the main CPU capacity. The unit supports both incremental and absolute position detection methods, making it adaptable to varied industrial field configurations.

Features

  • Four-axis control capability supporting independent axis configuration and linear interpolation.
  • Open collector pulse output structure reaching a maximum output rate of 200 kpulse/s.
  • Rapid start response time of 1.5 ms for 1-axis speed control operations.
  • Extensive internal storage holding up to 600 positioning sequences per axis.
  • Dual-coordinate method implementation supporting both absolute and incremental positioning profiles.
  • Low internal thermal footprint with a 5 VDC current consumption of only 0.36 A.

Applications

  • Multi-axis pick-and-place gantry systems
  • Packaging, wrapping, and labeling machinery
  • Material handling systems and synchronized conveyor lines
  • Automated assembly and test fixtures

Technical Specifications

Manufacturer Mitsubishi Electric
Part Number/Model QD75P4N
Series MELSEC-Q Series
Product Type Positioning Unit
Number of Control Axes 4 axes
Positioning Data Storage 600 data sequences / axis
Output Pulse Method Open collector output
Maximum Output Pulse Rate 200 kpulse/s
1-Axis Speed Control Start Time 1.5 ms
Trajectory Control Methods Increment method, absolute method
Internal Current Consumption (5 VDC) 0.36 A
Shipping Weight 3.0 kg

Installation Guidelines

To ensure operational safety and signal integrity when installing the QD75P4N module, execute the following steps:

  • Power Isolation: Shut down all external power supplies and the PLC rack power before mounting or removing the positioning module.
  • Module Retention: Securely seat the module onto the MELSEC-Q base unit guide slot and tighten the module fixing screw to prevent shifting due to machine vibration.
  • Cable Routing: Route the 40-pin drive interface cables away from high-voltage AC mains power lines and motor drive outputs to mitigate electrical noise interference.
  • Shield Grounding: Ground the shield drain wire of the command signal cables to the designated panel earth bar near the PLC rack.

FAQ

How many axes can the QD75P4N module control?

The QD75P4N is capable of controlling up to 4 axes, supporting independent configurations as well as interpolation sequences.

What is the maximum pulse output rate of the QD75P4N?

The module features an open collector pulse output method with a maximum output rate of 200 kpulse/s.

How much positioning data can be stored on the QD75P4N?

The QD75P4N can store up to 600 positioning data points per axis directly on the module.

Does the QD75P4N support absolute positioning systems?

Yes, the module supports both the incremental method and the absolute system method for trajectory coordinate control.

What is the internal 5V current consumption of this unit?

The QD75P4N draws an internal current of 0.36 A from the 5 VDC bus on the MELSEC-Q base unit.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.