Description

Optimized for high-density data acquisition, the Omron C200H-AD003 serves as a dedicated multi-channel analog input interface within legacy SYSMAC C200H, C200HS, and C200HX/HG/HE control architectures. This industrial module converts continuous analog signals from field transmitters, sensors, and instrumentation into precise digital values for direct processing by the PLC central unit. Engineered for robust performance in demanding electrical environments, it features integrated phototransistor isolation between field terminals and internal logic circuitry to protect the backplane from voltage spikes and common-mode electrical noise.

Features

  • Multi-Channel Density: Eight independent, single-ended analog input channels housed within a single-slot module width.
  • Flexible Input Ranges: Direct support for standard industrial signal ranges, including 1 to 5 VDC, 0 to 10 VDC, -10 to +10 VDC, and 4 to 20 mA current loops.
  • High-Resolution Conversion: 12-bit analog-to-digital conversion provides a clean 1/4000 full-scale resolution for highly accurate process variable reproduction.
  • System-Level Protection: Photocoupler isolation ensures galvanic separation of up to 500 VAC between field wiring terminals and the PLC internal bus.
  • Direct Rack Integration: Mounts directly onto any standard C200H CPU, Expansion, or Remote I/O backplane without requiring external conversion adapters.

Applications

  • Process Industry Monitoring: Real-time temperature, pressure, and level sensor monitoring in chemical processing and water treatment facilities.
  • Factory Automation: Interfacing with laser displacement sensors, encoders, and thickness gauges on manufacturing assembly lines.
  • HVAC Systems Control: Feedback processing from environmental sensors, relative humidity transmitters, and air-flow transducers in commercial building control.
  • Legacy Machinery Retrofits: Seamless integration with existing Omron SYSMAC systems for performance-critical signal monitoring.

Technical Specifications Table

Parameter Specification Value
Manufacturer Omron Automation and Safety
Model / Part Number C200H-AD003
Compatible Series SYSMAC C200H / C200HS / C200HX / C200HG / C200HE
Number of Analog Inputs 8 channels
Input Signal Options (Voltage) 1 to 5 VDC, 0 to 10 VDC, -10 to +10 VDC
Input Signal Options (Current) 4 to 20 mA
A/D Resolution 12-bit (1/4000 of full scale)
Conversion Time Max. 1.0 ms per channel (8.0 ms cycle for all active channels)
Overall Accuracy +/-0.5% of full scale (voltage inputs), +/-0.6% of full scale (current inputs) at 25 degC
Isolation Resistance 20 MOhm minimum at 250 VDC between input terminals and PLC ground
Internal Power Consumption 5 VDC at 0.10 A max; 26 VDC at 0.10 A max
Mounting Method Direct backplane slot mounting with locking screws
Country of Origin Japan
Shipping Weight (Calculated) 1.0 kg
Package Dimensions (Calculated) 150 mm x 130 mm x 45 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The C200H-AD003 is backward-compatible across standard C200H chassis installations. When migrating legacy platforms to contemporary CS/CJ series, note that direct physical slot migration is not supported. You must utilize a CS1W-BC series backplane with specialized bus converters, or rewrite the analog configuration registers within CX-Programmer to target native CS1W-AD series analog input units.

Application Pitfalls & Engineering Notes

This module uses a single-ended design with shared internal analog grounds (AG). It is highly susceptible to ground loops if field-side transmitters operate on different ground potentials. To prevent measurement drift or absolute offset errors, utilize external loop isolators for active transmitters that do not share a common zero-volt reference with the PLC system power supply.

Commissioning & Wiring Tips

Always route analog input cables using twisted-pair, shielded instrumentation cables. Ground the shield at the PLC-side ground terminal (GR) only; do not ground both ends of the shield to avoid induced electromagnetic currents. Keep all analog paths separated from high-current AC motor leads by a minimum distance of 200 mm.

Installation Guidelines

CRITICAL WARNING:

Never insert or remove the C200H-AD003 module from the backplane while the PLC power supply is switched on. Hot-swapping will damage the system's internal bus driver chips and invalidate hardware warranties. Prior to physical installation, ensure all supply lines are fully isolated and check for residual capacitive charges.

  1. 1 Isolate PLC Main Power: Shut down and tag out the primary AC or DC supply supplying power to the rack chassis assembly. Verify that the PLC power LED indicator is completely dark.
  2. 2 Address Configuration: Adjust the hardware rotary switches located on the front bezel of the module to assign the designated unit number in accordance with your software memory allocation map.
  3. 3 Physical Mount: Align the module hooks with the upper slot groove of the C200H backplane, tilt the unit down, and press firmly until the bottom connector seats fully into the backplane receiver.
  4. 4 Fasten Unit Screws: Secure the upper mounting and lower locking screws to ensure vibration-proof installation in industrial enclosures.
  5. 5 Terminal Block Hookup: Terminate your shielded field cables directly onto the detachable 20-point terminal assembly. Tighten terminal connection screws to a recommended torque of 0.5 N-m.
Loading product navigation…

What is the channel resolution of this module?

The module provides 12-bit analog-to-digital resolution, which translates to a digital scale representation of 1 to 4000.

Are the eight analog input channels isolated from one another?

No, the input channels share a common analog ground. They are isolated from the PLC internal bus circuitry via photocouplers, but not individually isolated from each other.

What input signal ranges are supported?

It supports selectable standard industrial ranges: 1 to 5 VDC, 0 to 10 VDC, -10 to +10 VDC, and 4 to 20 mA current loops.

Can this unit be mounted directly on CS1 series racks?

No, it is a legacy C200H form factor module. Direct mounting to a CS1 rack requires a compatibility backplane or bus adapter module.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Recently Viewed Products

Technical knowledge

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...