Description
The Omron CJ1W-NC413 is a high-density, 4-axis position control module designed for integration with the Omron SYSMAC CJ-series PLC systems. Functioning as a high-speed Special I/O Unit, this module provides precise, open-loop multi-axis positioning via open-collector pulse train outputs. It enables seamless command execution and positioning profiles for stepping motor drivers and servo drives. Designed for demanding automated systems, the CJ1W-NC413 optimizes motion paths and high-speed feed rates while minimizing CPU processing overhead by handling motion profiles independently on the module.
Features
- Supports independent or coordinated control of up to 4 axes from a single PLC slot.
- Generates open-collector pulse train outputs suitable for stepping motors and servo drives.
- Features high-speed positioning operations with rapid pulse start times.
- Supports continuous positioning, interrupt feeding, and absolute/relative positioning sequences.
- Utilizes a high-density connector interface to minimize space within the control cabinet.
Applications
- Packaging machinery and automated labeling systems.
- Pick-and-place gantry systems and material handling systems.
- Assembly line automation and multi-axis indexing tables.
- Semiconductor manufacturing and electronic component insertion machinery.
Technical Specifications
Parameter
Specification
| Manufacturer |
Omron |
| Model / Part Number |
CJ1W-NC413 |
| Series |
SYSMAC CJ Series |
| Module Type |
Position Control Unit (Special I/O Unit) |
| Number of Controlled Axes |
4 axes |
| Control Method |
Open-loop control via pulse train output |
| Output Type |
Open collector |
| I/O Allocated Words |
20 words (Special I/O Unit Area) |
| External Power Supply Requirements |
24V DC |
| Operating Temperature |
0 to 55 degC |
| Storage Temperature |
-20 to 75 degC |
| Ambient Operating Humidity |
10% to 90% RH (non-condensing) |
Installation Guidelines
- Ensure the PLC rack power supply is completely switched off before mounting or removing the CJ1W-NC413 module.
- Connect the external 24V DC power supply specifically dedicated to the output circuit to protect against electrical noise and command signal degradation.
- Use shielded, twisted-pair cables for pulse train command lines and ground the shield at the drive end to mitigate electromagnetic interference (EMI).
- Maintain adequate clearance around the PLC rack to ensure proper convection cooling within the specified ambient temperature range of 0 to 55 degC.