Engineered for high-speed, high-capacity machine control, the Omron CJ2H-CPU68 central processing unit serves as the core processor for CJ2-series programmable logic controllers. This unit manages complex automation tasks with a large 400K step user memory and a highly optimized execution cycle. Designed for panel-mounted environments, it delivers exceptional operational speed with basic instruction times as low as 0.016 us. The integrated memory architectures support extensive function block definitions, automatic address allocations, and broad data logging capabilities via optional memory cards, making it a reliable standard for demanding industrial processing architectures.

Key Features

  • High-Speed Execution: Basic instruction execution at 0.016 us minimum and special instructions at 0.048 us minimum.
  • Massive Memory Capacity: Features 400K steps of program memory to accommodate complex logic and large program structures.
  • Flexible Data Allocations: Access to EM Area force-setting/resetting across Banks 0 to 18 hex, with automatic address allocation on Banks 11 to 18 hex.
  • Extensive I/O Architecture: Supports up to 2560 logical I/O bits to handle extensive fieldbus and physical digital/analog point systems.
  • Robust Task Management: Accommodates up to 128 cyclic task flags and supports up to 2048 function block definitions and instances.

Applications

  • High-speed packaging and sorting machinery.
  • Multi-axis coordinated motion control systems.
  • Automotive assembly line PLC networks.
  • Process instrumentation control panels requiring fast scan times.

Technical Specifications

Parameter Value
Manufacturer Omron
Model Number CJ2H-CPU68
Series CJ2 Family / CJ2H
Enclosure Rating Mounted in a panel
Grounding Requirement Less than 100 Ohms
Current Consumption 0.42 A at 5 VDC
User Program Memory 400K steps
I/O Capacity 2560 bits
Overhead Processing Time 100 us
Basic Instruction Execution 0.016 us minimum
Special Instruction Execution 0.048 us minimum
EM Area Force-Set/Reset Banks 0 - 18 hex
Automatic Address Allocation Banks 11 - 18 hex
Cyclic Task Flags 128 flags
Memory Card Compatibility 128 MB, 256 MB, or 512 MB
Function Block Definitions 2048 maximum
Function Block Instances 2048 maximum
Communications Method Half-duplex, Start-stop synchronization
Baud Rate Range 0.3 to 115.2 kbps
Maximum Serial Distance 15 meters max
Physical Dimensions 6.5 cm x 4.9 cm x 9.0 cm
Net Weight 0.2 kg
Shipping Weight (Calculated) 2.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

When migrating legacy systems from the CJ1 series (e.g., CJ1H or CJ1G) to the CJ2H architecture, the physical footprint remains highly compatible, but memory map allocations require verification in CX-Programmer. The CJ2H series utilizes an expanded Extended Memory (EM) bank structure up to 18 hex, which is significantly larger than previous generations. Ensure that peripheral tool versions are updated to support the CJ2H instruction set to prevent compilation errors during download.

Application Pitfalls & Engineering Notes

A common point of failure in high-speed applications is over-allocating force-set/reset memory flags in non-designated EM banks. In this unit, ensure that force-setting/resetting operations remain confined to Banks 0 through 18 hex, and that automatic memory allocations do not overwrite manual configurations in Banks 11 through 18 hex. Also, monitor the 100 us overhead processing time; when executing massive functional block nesting (up to the 2048 limit), scan times can lengthen if execution paths are not carefully structured.

Commissioning & Wiring Tips

For reliable communication performance, functional grounding must be strictly verified. The grounding path must maintain a resistance of less than 100 Ohms to mitigate high-frequency electrical noise from nearby variable frequency drives (VFDs). When utilizing the built-in serial communication port at higher baud rates (such as 115.2 kbps), use double-shielded twisted-pair cabling and do not exceed the 15-meter maximum distance limit to avoid transmission errors.

Installation Guidelines

CRITICAL WARNING: Prior to mounting or wiring the CPU module, disconnect all external power supplies to the rack. Failure to completely de-energize the system may cause electrical shock, physical damage to the internal CMOS circuitry of the module, or unpredictable system behaviors.
1
Align the lock claws on the upper and lower portions of the CPU module with the adjacent power supply module on the CJ-series backplane.
2
Carefully press the module straight onto the bus connector until it clicks securely into place, ensuring no pins are bent.
3
Slide the yellow lock levers on the top and bottom of the module forward to lock the unit securely to the backplane.
4
Connect the functional ground terminal to a dedicated ground point keeping the impedance strictly under 100 Ohms.

What is the processing speed of the CPU module for basic and special instructions?

The module executes basic instructions in a minimum of 0.016 microseconds and special instructions in a minimum of 0.048 microseconds, keeping cyclic overhead processing to approximately 100 microseconds.

Which Extended Memory (EM) banks support force-setting and resetting?

Force-setting and resetting operations are compatible with EM Area Banks 0 through 18 hex. Automated address allocation is assigned specifically to Banks 11 through 18 hex.

What functional grounding specification is required for this PLC unit?

To prevent high-frequency noise interference in demanding industrial panel layouts, a dedicated functional grounding connection with a resistance of less than 100 Ohms must be installed.

What is the maximum supported memory card size for data storage?

This unit is compatible with standard industrial-grade CompactFlash memory cards in capacities of 128 MB, 256 MB, or 512 MB.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...