Executing automation routines via a stored program architecture, the Omron CP1L-M30DT-D micro-PLC delivers high-performance processing coupled with integrated Ethernet communications. Designed to fit within compact panel layouts, this CP1L series CPU module utilizes a cyclic scan processing method with immediate I/O refreshing, enabling high-speed response times for complex machinery. The unit supports versatile programming options, allowing engineers to write logic using standardized ladder diagrams and Structured Text (ST) inside function blocks, ensuring seamless integration into modern industrial control architectures.

Features

  • Flexible Programming Environment: Supports up to 128 function block definitions and 256 instances using ladder logic and Structured Text (ST).
  • High-Speed Instruction Execution: Executes basic logical instructions in 0.55 us minimum and special instructions in 4.1 us minimum.
  • Robust Task Management: Manages up to 288 concurrent tasks, structured as 32 cyclic tasks and 256 interrupt tasks.
  • Integrated Analog Channel: Features one onboard analog input (0 to 10 VDC range) with a 1/256 resolution for basic voltage monitoring without auxiliary cards.
  • Expandable Hardware Design: Allows physical expansion of system capacity by connecting up to 3 CP-series expansion or I/O units.

Applications

  • Packaging and labeling machinery requiring high-speed execution.
  • Material handling systems, conveyor control, and sorting systems.
  • Pump control panels and water distribution systems requiring embedded Ethernet telemetry.
  • Custom machine-tool automation utilizing interrupt inputs and high-speed counter modes.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number CP1L-M30DT-D
Control Method Stored program method
I/O Control Method Cyclic scan with immediate refreshing
Program Capacity 10K steps
Basic Instruction Execution Time 0.55 us (microseconds) minimum
Special Instruction Execution Time 4.1 us (microseconds) minimum
Common Processing Time 0.4 ms
Input Area 1,600 bits (100 words), CIO 0 to CIO 99
Output Area 1,600 bits (100 words), CIO 100 to CIO 199
Work Bits 8,192 bits (512 words), W0 to W511
Holding Area 8,192 bits (512 words), H0 to H511
Timers 4,096 timer numbers (T0 to T4095)
Interrupt Inputs 6 inputs (Response time: 0.3 ms)
Interrupt Counter Mode 6 inputs (Response frequency: 5 kHz max), 16-bit up/down
Analog Controls 1 adjustment dial (Setting range: 0 to 255)
Onboard Analog Input 1 input (0 to 10 V, 1/256 resolution, non-isolated)
Shipping Weight (Calculated) 3.00 kg (with protective distribution packaging)

Empirical Engineering Insights

Alternative Models & Compatibility

The CP1L-M30DT-D requires a nominal 24 VDC power source, as indicated by the trailing "-D" suffix. Care must be taken not to substitute this model directly with the "-A" variant (e.g., CP1L-M30DT-A), which operates on 100-240 VAC mains power. Converting programs from older CP1E systems to CP1L is fully supported within CX-Programmer, though physical terminal configuration differences must be verified prior to downloading the updated task structures.

Application Pitfalls & Engineering Notes

The integrated 0-10 VDC analog input is non-isolated. Deploying this input in environments with high electromagnetic interference (EMI) or severe ground potential differences can corrupt analog measurements. For reliable performance, keep signal cables as short as possible, route them away from variable frequency drive (VFD) output cables, and use high-quality shielded twisted-pair wiring. If isolation is critical, use an external signal isolator before routing to the controller.

Commissioning & Wiring Tips

When configuring the embedded Ethernet interface, ensure the local subnet of your programming workstation matches the PLC default IP allocation. High-speed interrupt inputs (configured for 5 kHz counter operations) require low-capacitance cabling to avoid pulse signal dampening. Ensure the functional ground (FG) terminal is securely tied to a low-impedance earth ground to maximize internal noise filtering performance.

Installation Guidelines

CRITICAL WARNING

Isolate all electrical power sources before attempting mounting, removal, or connection of the CPU module. Confirm that the input voltage matches the specified 24 VDC threshold. Failure to disconnect active field wiring or applying incorrect input voltages can result in permanent hardware failure, circuit damage, or electric shock.

1 Mount the CPU module securely onto standard 35 mm DIN rail or directly to the panel backplate using the mounting screws, ensuring adequate ventilation spacing of at least 50 mm above and below the unit.
2 Connect the external 24 VDC power supply to the dedicated power terminals. Double-check polarity configuration to prevent internal fuse degradation.
3 Ground the PLC functional ground (FG) terminal directly to the panel main earth ground bar using a low-impedance conductor of at least 2.0 mm square.
4 Terminate industrial Ethernet and high-speed I/O field cables, keeping signal lines separate from high-voltage AC lines to minimize signal interference.

FAQ

What is the power supply requirement for this controller?

The 'D' suffix in the model code indicates a 24 VDC power supply requirement. Do not connect AC mains power directly to this unit.

What is the resolution of the built-in analog input?

The onboard analog input has a resolution of 1/256 with an input range of 0 to 10 VDC. Note that this integrated analog channel is non-isolated.

How many expansion units can be connected?

A maximum of 3 CP-series expansion units or expansion I/O units can be directly connected to expand system capabilities.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Technical knowledge

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.

Securing Remote PLC Access Beyond the VPN

A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...