Designed for micro-spot laser sensing and highly detailed parts verification, the Omron E3C-LDA11 functions as a high-precision photoelectric sensor separate digital amplifier. This high-performance DIN-rail mount unit connects to separate Omron laser photoelectric sensor heads, providing dual-channel digital monitoring and high-speed processing directly inside electrical enclosures. By separating the optical head from the processing electronics, the E3C-LDA11 keeps critical evaluation circuitry isolated from demanding field conditions while offering NPN outputs, dual digital displays, and extensive parameter customization via intuitive tactile keys.
| Parameter | Specification |
|---|---|
| Manufacturer | Omron |
| Model Number | E3C-LDA11 |
| Product Type | Photoelectric Sensor Separate Digital Amplifier |
| Supply Voltage | 12 to 24 VDC plus/minus 10% (ripple p-p 10% max.) |
| Current Consumption | 45 mA maximum |
| Control Output | NPN open collector, load current 50 mA max., residual voltage 1 V max. |
| Light Source Capability | Compatible with E3C-LD series sensor heads (Red Laser) |
| Protection Circuits | Power supply reverse polarity protection, output short-circuit protection, mutual interference prevention |
| Ingress Protection Rating | IP50 (IEC 60529) |
| Ambient Operating Temperature | -10 to +55 degC (no icing or condensation) |
| Connection Method | Pre-wired cable (standard length 2 meters) |
| Net Weight | 0.1 kg |
| Shipping Weight (Calculated) | 1.0 kg (with protective transport packaging) |
| Wire Color | Signal Name | Function / Description |
|---|---|---|
| Brown | +V (VCC) | Power Supply Input: 12 to 24 VDC |
| Blue | 0 V (GND) | Power Supply Ground / Common Reference |
| Black | OUT 1 | NPN Open Collector Control Output (Main detection signal) |
| White | OUT 2 / INPUT | NPN Output 2 (Self-diagnostic/Alarm) or External Input line (Configurable) |
The E3C-LDA11 utilizes NPN output logic. If your system architecture uses PNP (typically standard in European automotive and material handling panels), you must specify model E3C-LDA41 instead. Do not mix NPN and PNP models in the same localized terminal bank without signal conversion modules. This amplifier is specifically calibrated to operate with the E3C-LD series laser head units; attempting to connect older, non-laser photoelectric heads may damage the physical emitter interface or throw sensor-mismatch error codes.
When packing multiple E3C-LDA11 units together on a single DIN rail, heat dissipation must be taken into account. Although the nominal operating range extends to +55 degC, side-by-side array installations of more than five units under continuous load can lead to thermal accumulation, shifting internal clock frequencies and altering precise threshold values. We recommend inserting 5mm spacer plates between blocks of five units to preserve baseline thermal equilibrium.
During commissioning, verify that the laser head's connection cable is securely locked into the amplifier side-port prior to supplying 24VDC control voltage. Hot-plugging the sensor head can induce transient electrical spikes that degrade the laser diode. Ground the DIN rail thoroughly to mitigate electromagnetic interference, which can otherwise trigger false microsecond-level detection signals in high-speed sensing modes.
Global Express Shipping
Returns & Warranty

Designed for micro-spot laser sensing and highly detailed parts verification, the Omron E3C-LDA11 functions as a high-precision photoelectric sensor separate digital amplifier. This high-performance DIN-rail mount unit connects to separate Omron laser photoelectric sensor heads, providing dual-channel digital monitoring and high-speed processing directly inside electrical enclosures. By separating the optical head from the processing electronics, the E3C-LDA11 keeps critical evaluation circuitry isolated from demanding field conditions while offering NPN outputs, dual digital displays, and extensive parameter customization via intuitive tactile keys.
| Parameter | Specification |
|---|---|
| Manufacturer | Omron |
| Model Number | E3C-LDA11 |
| Product Type | Photoelectric Sensor Separate Digital Amplifier |
| Supply Voltage | 12 to 24 VDC plus/minus 10% (ripple p-p 10% max.) |
| Current Consumption | 45 mA maximum |
| Control Output | NPN open collector, load current 50 mA max., residual voltage 1 V max. |
| Light Source Capability | Compatible with E3C-LD series sensor heads (Red Laser) |
| Protection Circuits | Power supply reverse polarity protection, output short-circuit protection, mutual interference prevention |
| Ingress Protection Rating | IP50 (IEC 60529) |
| Ambient Operating Temperature | -10 to +55 degC (no icing or condensation) |
| Connection Method | Pre-wired cable (standard length 2 meters) |
| Net Weight | 0.1 kg |
| Shipping Weight (Calculated) | 1.0 kg (with protective transport packaging) |
| Wire Color | Signal Name | Function / Description |
|---|---|---|
| Brown | +V (VCC) | Power Supply Input: 12 to 24 VDC |
| Blue | 0 V (GND) | Power Supply Ground / Common Reference |
| Black | OUT 1 | NPN Open Collector Control Output (Main detection signal) |
| White | OUT 2 / INPUT | NPN Output 2 (Self-diagnostic/Alarm) or External Input line (Configurable) |
The E3C-LDA11 utilizes NPN output logic. If your system architecture uses PNP (typically standard in European automotive and material handling panels), you must specify model E3C-LDA41 instead. Do not mix NPN and PNP models in the same localized terminal bank without signal conversion modules. This amplifier is specifically calibrated to operate with the E3C-LD series laser head units; attempting to connect older, non-laser photoelectric heads may damage the physical emitter interface or throw sensor-mismatch error codes.
When packing multiple E3C-LDA11 units together on a single DIN rail, heat dissipation must be taken into account. Although the nominal operating range extends to +55 degC, side-by-side array installations of more than five units under continuous load can lead to thermal accumulation, shifting internal clock frequencies and altering precise threshold values. We recommend inserting 5mm spacer plates between blocks of five units to preserve baseline thermal equilibrium.
During commissioning, verify that the laser head's connection cable is securely locked into the amplifier side-port prior to supplying 24VDC control voltage. Hot-plugging the sensor head can induce transient electrical spikes that degrade the laser diode. Ground the DIN rail thoroughly to mitigate electromagnetic interference, which can otherwise trigger false microsecond-level detection signals in high-speed sensing modes.
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
Japan
|