1 of 1

Omron E5CC-RX2ADM-800 E5CC Series Digital Temperature Controller

Omron E5CC-RX2ADM-800 E5CC Series Digital Temperature Controller

Only 7 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: E5CC-RX2ADM-800

  • Country of origin:Japan

  • Product Type: Digital Temperature Controllers

  • Payment: T/T, Western Union

  • Weight: 130g

  • Dimensions: 110 mm x 65 mm x 65 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for highly precise thermal process regulation, the Omron E5CC-RX2ADM-800 digital temperature controller delivers advanced PID control within a compact 48x48 mm (1/16 DIN) form factor. This instrument features a high-contrast white LCD display with 15.2 mm character heights, ensuring maximum legibility in high-density control panels. Operating on a 24 VAC/VDC auxiliary power supply, the unit integrates 2-PID control logic with automatic tuning to minimize overshoot and stabilize temperature fluctuations in demanding thermal systems. Built with a relay control output and dual auxiliary outputs, this hardware is engineered for direct integration into industrial machines, packaging lines, and environmental chambers.

Features

  • Universal Sensor Input: Direct support for multi-range thermocouples, platinum resistance thermometers (RTDs), and analog current/voltage inputs.
  • Dual Auxiliary Relays: Two independent auxiliary relay outputs for alarms, limit controls, or system interlocks.
  • Advanced Control Algorithms: High-speed sampling loop of 50 ms combined with 2-PID control and auto-tuning (AT) capabilities.
  • Enhanced Visibility: Large, easy-to-read white PV display segment contrasted against a dark background.
  • Compact Depth: Only 60 mm depth behind the panel, minimizing enclosure footprint and maximizing wiring space.

Applications

  • Plastic Extrusion & Molding: Accurate barrel zone heating control and die temperature stabilization.
  • Packaging Machinery: Precise sealing bar temperature management to ensure consistent package integrity.
  • Industrial Ovens & Furnaces: High-reliability thermal profiling and multi-stage heating curve regulation.
  • Food & Beverage Processing: Sanitation-compliant temperature monitoring and pasteurization loop control.

Technical Specifications Table

Parameter Specification Value
Manufacturer Omron
Model Code E5CC-RX2ADM-800
Supply Voltage 24 VAC (50/60 Hz) / 24 VDC
Operating Voltage Range 85% to 110% of rated supply voltage
Power Consumption Max 4.1 VA (24 VAC) / Max 2.3 W (24 VDC)
Control Output 1 Relay output (SPST-NO, 250 VAC, 3 A resistive load)
Auxiliary Outputs 2 Relay outputs (SPST-NO, 250 VAC, 3 A resistive load)
Control Method ON/OFF control or 2-PID control (with auto-tuning)
Sampling Period 50 ms
Terminal Connection Type Screw terminal block (M3)
Front Panel Dimensions 48 x 48 mm
Operating Ambient Temp -10 to 55 degC (with no condensation or icing)
Shipping Weight (Calculated) 0.35 kg
Package Dimensions (Calculated) 110 mm x 65 mm x 65 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The E5CC-RX2ADM-800 serves as a direct functional replacement for legacy models such as the E5CN-R2MD-500 series. However, when migrating to the E5CC platform, verify the wiring terminations: the E5CC uses a different physical pin layout relative to older generations. If your application relies on voltage pulse output for solid-state relays (SSRs), do not use the RX model; select the E5CC-QX2ADM-800 instead to prevent damage to the relay mechanism caused by high-frequency switching.

Application Pitfalls & Engineering Notes

Because this model is rated for 24 VAC/VDC power, it is highly sensitive to voltage drops along long DC distribution lines in control panels. Ensure that the power supply is situated close to the instrument and is isolated from heavy inductive switching devices. Running auxiliary outputs with high-current AC loads near their 3 A limit without RC snubbers will significantly shorten the electrical lifespan of the internal output relays due to contact arcing.

Commissioning & Wiring Tips

To configure parameters prior to cabinet powering, use the Omron CX-Thermo software paired with the front-panel setup port interface. This approach allows parameter configuration over a USB bus power connection, completely eliminating the need to connect 24V field power during the engineering phase. Ensure that you ground the analog shield wire of the sensor close to the panel entry point rather than routing it alongside high-voltage AC cables.

Installation Guidelines

CRITICAL WARNING: Prior to attempting physical installation, mounting, or terminal wiring, ensure that the primary electrical power source to the control cabinet is completely de-energized. Confirm the absence of residual AC/DC voltages using a calibrated digital multimeter. Failure to isolate power may cause electrical shock, physical hazard, or permanent failure of the internal logic circuits.
1
Insert the controller housing through the prepared 45x45 mm panel cutout from the front, ensuring the protective rubber gasket is correctly seated to maintain the IP66 water-resistant seal.
2
Slide the plastic mounting adapter from the rear of the panel along the controller body until the adapter clicks firmly against the panel backplate. Tighten the securing screws evenly to prevent frame distortion.
3
Terminate the universal input lines (thermocouple or RTD) using high-quality insulated crimp lugs to avoid signal noise. Route power and control output wires along dedicated low-voltage wireways separated from motor drive leads.
Loading product navigation…

Can the E5CC-RX2ADM-800 model be powered directly by standard 120 VAC or 240 VAC mains voltage?

No. The RX2ADM suffix indicates the unit is strictly designed for 24 VAC or 24 VDC auxiliary power. Connecting line voltage (100 to 240 VAC) directly to the power terminals will permanently destroy the internal electronic components.

Does this temperature controller support Pt100 RTD sensor inputs, or is it thermocouple-only?

This controller features a universal input. By configuring the input type parameter, you can configure it for multiple thermocouple types (K, J, T, E, etc.), platinum resistance thermometers (Pt100, JPt100), and analog current or voltage signals.

What is the contact rating of the primary control relay on the E5CC-RX2ADM-800?

The primary control output (Output 1) is a single-pole, single-throw, normally open (SPST-NO) relay rated for 250 VAC at 3 A under a purely resistive load.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...