Omron

Omron E5CC-RX2ADM-800 E5CC Series Digital Temperature Controller

SKU E5CC-RX2ADM-800

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Omron

  • Product No.: E5CC-RX2ADM-800

  • Country of origin:Japan

  • Product Type: Digital Temperature Controllers

  • Payment: T/T, Western Union

  • Weight: 130g

  • Dimensions: 110 mm x 65 mm x 65 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Designed for highly precise thermal process regulation, the Omron E5CC-RX2ADM-800 digital temperature controller delivers advanced PID control within a compact 48x48 mm (1/16 DIN) form factor. This instrument features a high-contrast white LCD display with 15.2 mm character heights, ensuring maximum legibility in high-density control panels. Operating on a 24 VAC/VDC auxiliary power supply, the unit integrates 2-PID control logic with automatic tuning to minimize overshoot and stabilize temperature fluctuations in demanding thermal systems. Built with a relay control output and dual auxiliary outputs, this hardware is engineered for direct integration into industrial machines, packaging lines, and environmental chambers.

Features

  • Universal Sensor Input: Direct support for multi-range thermocouples, platinum resistance thermometers (RTDs), and analog current/voltage inputs.
  • Dual Auxiliary Relays: Two independent auxiliary relay outputs for alarms, limit controls, or system interlocks.
  • Advanced Control Algorithms: High-speed sampling loop of 50 ms combined with 2-PID control and auto-tuning (AT) capabilities.
  • Enhanced Visibility: Large, easy-to-read white PV display segment contrasted against a dark background.
  • Compact Depth: Only 60 mm depth behind the panel, minimizing enclosure footprint and maximizing wiring space.

Applications

  • Plastic Extrusion & Molding: Accurate barrel zone heating control and die temperature stabilization.
  • Packaging Machinery: Precise sealing bar temperature management to ensure consistent package integrity.
  • Industrial Ovens & Furnaces: High-reliability thermal profiling and multi-stage heating curve regulation.
  • Food & Beverage Processing: Sanitation-compliant temperature monitoring and pasteurization loop control.

Technical Specifications Table

Parameter Specification Value
Manufacturer Omron
Model Code E5CC-RX2ADM-800
Supply Voltage 24 VAC (50/60 Hz) / 24 VDC
Operating Voltage Range 85% to 110% of rated supply voltage
Power Consumption Max 4.1 VA (24 VAC) / Max 2.3 W (24 VDC)
Control Output 1 Relay output (SPST-NO, 250 VAC, 3 A resistive load)
Auxiliary Outputs 2 Relay outputs (SPST-NO, 250 VAC, 3 A resistive load)
Control Method ON/OFF control or 2-PID control (with auto-tuning)
Sampling Period 50 ms
Terminal Connection Type Screw terminal block (M3)
Front Panel Dimensions 48 x 48 mm
Operating Ambient Temp -10 to 55 degC (with no condensation or icing)
Shipping Weight (Calculated) 0.35 kg
Package Dimensions (Calculated) 110 mm x 65 mm x 65 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The E5CC-RX2ADM-800 serves as a direct functional replacement for legacy models such as the E5CN-R2MD-500 series. However, when migrating to the E5CC platform, verify the wiring terminations: the E5CC uses a different physical pin layout relative to older generations. If your application relies on voltage pulse output for solid-state relays (SSRs), do not use the RX model; select the E5CC-QX2ADM-800 instead to prevent damage to the relay mechanism caused by high-frequency switching.

Application Pitfalls & Engineering Notes

Because this model is rated for 24 VAC/VDC power, it is highly sensitive to voltage drops along long DC distribution lines in control panels. Ensure that the power supply is situated close to the instrument and is isolated from heavy inductive switching devices. Running auxiliary outputs with high-current AC loads near their 3 A limit without RC snubbers will significantly shorten the electrical lifespan of the internal output relays due to contact arcing.

Commissioning & Wiring Tips

To configure parameters prior to cabinet powering, use the Omron CX-Thermo software paired with the front-panel setup port interface. This approach allows parameter configuration over a USB bus power connection, completely eliminating the need to connect 24V field power during the engineering phase. Ensure that you ground the analog shield wire of the sensor close to the panel entry point rather than routing it alongside high-voltage AC cables.

Installation Guidelines

CRITICAL WARNING: Prior to attempting physical installation, mounting, or terminal wiring, ensure that the primary electrical power source to the control cabinet is completely de-energized. Confirm the absence of residual AC/DC voltages using a calibrated digital multimeter. Failure to isolate power may cause electrical shock, physical hazard, or permanent failure of the internal logic circuits.
1
Insert the controller housing through the prepared 45x45 mm panel cutout from the front, ensuring the protective rubber gasket is correctly seated to maintain the IP66 water-resistant seal.
2
Slide the plastic mounting adapter from the rear of the panel along the controller body until the adapter clicks firmly against the panel backplate. Tighten the securing screws evenly to prevent frame distortion.
3
Terminate the universal input lines (thermocouple or RTD) using high-quality insulated crimp lugs to avoid signal noise. Route power and control output wires along dedicated low-voltage wireways separated from motor drive leads.

FAQ

Can the E5CC-RX2ADM-800 model be powered directly by standard 120 VAC or 240 VAC mains voltage?

No. The RX2ADM suffix indicates the unit is strictly designed for 24 VAC or 24 VDC auxiliary power. Connecting line voltage (100 to 240 VAC) directly to the power terminals will permanently destroy the internal electronic components.

Does this temperature controller support Pt100 RTD sensor inputs, or is it thermocouple-only?

This controller features a universal input. By configuring the input type parameter, you can configure it for multiple thermocouple types (K, J, T, E, etc.), platinum resistance thermometers (Pt100, JPt100), and analog current or voltage signals.

What is the contact rating of the primary control relay on the E5CC-RX2ADM-800?

The primary control output (Output 1) is a single-pole, single-throw, normally open (SPST-NO) relay rated for 250 VAC at 3 A under a purely resistive load.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Technical knowledge

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.

Securing Remote PLC Access Beyond the VPN

A VPN encrypts the path to an industrial network, but secure remote PLC work also needs identity controls, segmented access, change approval, logging, safe operating boundaries, and tested recovery...