Omron CS1W-AD081-V1 CS Series Analog Input Unit

Omron CS1W-AD081-V1 CS Series Analog Input Unit

Only 5 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: CS1W-AD081-V1

  • Country of origin:Japan

  • Product Type: Analog Input Modules

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Dimensions: 155 x 135 x 45 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for seamless integration into Sysmac CS-Series PLC backplanes, the Omron CS1W-AD081-V1 Analog Input Unit provides high-density, multi-channel analog-to-digital signal conversion. This Special I/O Unit supports 8 independent analog input channels, allowing direct connection to industrial sensors, transmitters, and flowmeters. Each channel can be configured individually for diverse signal ranges, ensuring maximum system flexibility without requiring dedicated signal conditioning hardware. The module offers selectable high-resolution conversion profiles and robust noise-filtering parameters to deliver clean, reliable process variables to the CPU rack.

Key Features

  • Individual Channel Configuration: Select voltage or current input ranges independently for each of the 8 channels.
  • Selectable Resolution: Configurable conversion resolutions of 1/8,000 or 1/4,000 to match process accuracy requirements.
  • High-Speed Conversion: Operates at a conversion speed of up to 250 microseconds per point (settable to 1 millisecond per point).
  • Detachable Connections: Includes a 21-point detachable M3 screw terminal block for efficient field wiring and rapid module replacement.
  • Peak Hold Function: Stores maximum conversion values during high-speed transient monitoring cycles.

Applications

  • Chemical processing and multi-zone temperature logging.
  • Flow rate, hydraulic pressure, and level monitoring in water treatment infrastructure.
  • Pumping station control loops utilizing 4 to 20 mA feedback transmitters.
  • Factory automation and process integration on Sysmac CS1G, CS1H, and CS1D control platforms.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number CS1W-AD081-V1
Unit Type CS-Series Special I/O Unit
Number of Analog Inputs 8 inputs (non-isolated between channels, isolated from PLC bus)
Input Signal Ranges (Voltage) 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to +10 V
Input Signal Ranges (Current) 4 to 20 mA
Conversion Resolution 1/8,000 (settable to 1/4,000 via DM parameters)
Conversion Speed 250 microseconds/point max. (settable to 1 ms/point)
External Wiring Terminals 21-point detachable terminal block (M3 self-raising screws)
Internal Power Consumption 120 mA max. at 5 VDC, 90 mA max. at 26 VDC
Operating Temperature 0 to 55 degC
Country of Origin Japan
Shipping Weight (Calculated) 3.0 kg (including shipping protection and original OEM box)
Package Dimensions (Calculated) 155 x 135 x 45 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The CS1W-AD081-V1 is a direct replacement for the legacy, non-V1 CS1W-AD081 module. The "V1" suffix indicates enhanced internal filtering capabilities and optimized CPU bus communication protocols. When migrating older applications to this V1 hardware, ensure that your CX-Programmer I/O table is updated to reflect the V1 designation to prevent configuration mismatch faults (H-type I/O errors) during hardware download cycles.

Application Pitfalls & Engineering Notes

Note that the channels on the CS1W-AD081-V1 are isolated from the internal PLC logic bus, but are not isolated from channel to channel. They share a common ground line (COM). If you connect field transmitters that have differing ground potentials or use active loop-powered transmitters without 3-way isolation barriers, ground loops will occur. This will distort analog readings and could potentially damage the module's multiplexer circuitry. If channel-to-channel isolation is a project requirement, you must use external isolation signal converters or step up to a fully isolated analog module series.

Commissioning & Wiring Tips

To configure a channel for a 4 to 20 mA current input, you must bridge the voltage input terminal (V IN) with the current input terminal (I IN) using a jumper wire on the detachable terminal block. This short engages the internal precision 250-ohm shunt resistor. Failure to bridge these terminals when selecting current mode in the software configuration will result in an input out-of-range flag. Shielded twisted-pair cables are mandatory for all analog runs, and shields should be grounded at a single, clean grounding point (GR terminal) on the PLC panel side.

Installation Guidelines

CRITICAL WARNING

Always completely de-energize the PLC rack, CPU, and all external power supplies connected to field devices before mounting or removing the analog input module or detach/attach the M3 terminal block. Performing hot-swapping procedures will cause irreparable damage to the internal bus transceiver logic and will immediately void the manufacturer warranty.

1

Configure Unit Number: Set the two rotary switches on the front panel of the CS1W-AD081-V1 to select the desired unit number (MACH No.) within the allowable range (0 to 95). Ensure this does not conflict with existing special I/O units on the same bus.

2

Mount Unit to Backplane: Align the bottom hook of the module with the slot on the backplane, and swing the module upward until it seats firmly. Secure the top mounting screw to ensure robust grounding and mechanical connection.

3

Wire Field Signals: Connect the field sensor leads to the detachable 21-point terminal block. For current inputs, verify the V IN and I IN shorting jumper is securely installed. Tighten all M3 terminal screws to 0.5 N-m torque.

4

Software Parameters Download: In CX-Programmer, open the IO Table, register the module, and access the "Special I/O Unit Settings" to enable each channel, select range values, and specify conversion speed before executing a CPU download.

Loading product navigation…

How are current inputs and voltage inputs configured on the terminal block?

For current inputs (4 to 20 mA), you must externally bridge the respective channel's voltage input terminal (V IN) and current input terminal (I IN) on the M3 block. This connects the internal 250-ohm precision shunt resistor. For voltage inputs, the signal wire connects directly to V IN, leaving I IN open.

Are the individual channels on the module isolated from each other?

No. The analog input channels are isolated from the internal PLC bus circuitry, but they are not isolated from channel to channel. They share a common analog return ground path (COM).

What is the difference between the legacy CS1W-AD081 and the CS1W-AD081-V1?

The V1 version includes optimized signal-filtering routines, improved diagnostic flags, and enhanced data transmission speeds across the PLC bus. The V1 is fully backward compatible but must be declared properly in the CX-Programmer I/O tables.

How is the analog resolution toggled between 1/4,000 and 1/8,000?

Resolution is adjusted via software configuration in the DM Area settings assigned to the Special I/O Unit. Changing the resolution dynamically alters the scaling register values read by the CPU.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Recently Viewed Products

Technical knowledge

Electric Actuators Designed to Replace Fluid Power Systems: A Practical Industrial Automation Guide

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Math Operations Using OpenPLC for Industrial Automation Applications

This article explains how PLC systems perform core mathematical operations such as addition, subtraction, multiplication, division, modulo, and exponentiation within industrial automation. It shows...

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...