Omron NJ101-9020 Sysmac NJ1 CPU Module with Database Connection

Omron NJ101-9020 Sysmac NJ1 CPU Module with Database Connection

Only 2 item(s) left in stock
  • Manufacturer: Omron

  • Product No.: NJ101-9020

  • Country of origin:Japan

  • Product Type: PLC CPU Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Dimensions: 90 mm x 90 mm x 90 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

Designed for direct transactional synchronization between machine-level automation and enterprise SQL databases, the Omron NJ101-9020 functions as a high-performance central processing unit within the Sysmac NJ platform. This controller eliminates the need for intermediate PC-based middleware or gateway computers by hosting an integrated SQL client. It enables real-time data logging, quality tracking, and recipe retrieval directly from the CPU to database servers over standard Ethernet. Built on a unified Sysmac architecture, the unit combines sequence control, motion configuration, and IT connectivity into a single, cohesive processing core.

Features

  • Direct SQL Integration: Built-in instructions support direct connection to Microsoft SQL Server, Oracle, MySQL, PostgreSQL, and Firebird.
  • Unified Control Platform: Execution of logic control, motion setup, and IT networking tasks within a single execution cycle.
  • Spooling Functionality: Automatically buffers SQL transactions to an industrial SD card in the event of an IT network failure, preventing data loss.
  • Secure Industrial Communications: Features isolated Ethernet ports for separate machine-level control (EtherCAT) and factory-level networking (EtherNet/IP).
  • Robust I/O Scalability: Supports expansion through the local CJ-series I/O bus and remote EtherCAT junctions.

Applications

  • Traceability and Serialization: Real-time storage of assembly metrics, barcode scans, and test results in pharmaceutical or automotive plants.
  • Recipe Management Systems: On-demand retrieval of product parameters and batch configurations directly from server-side ERP/MES databases.
  • Predictive Maintenance: Continuous logging of high-frequency machine variables, run-hours, and vibration profiles to central analytics databases.
  • Automated Warehousing: Direct communication with Warehouse Management Systems (WMS) for pallet routing and sorter control.

Technical Specifications

Manufacturer Omron
Model Number NJ101-9020
Series Sysmac NJ1
Primary Task Cycle Time 1.0 ms
Variables Memory Capacity 0.5 MB
Program Capacity 5 MB
Supported Databases Microsoft SQL Server, Oracle, MySQL, PostgreSQL, Firebird
Built-in Communication Ports 1x EtherCAT Master, 1x EtherNet/IP, 1x USB 2.0 (Type-B)
Max. EtherCAT Remote Nodes 64
Local Expansion Bus CJ-series I/O Bus
Max. Local Expansion Units 40 (requires CJ-series Expansion Racks)
Operating Temperature 0 to 55 degC
Dimensions (H x W x D) 90 mm x 90 mm x 90 mm
Net Weight 550 g
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Port / Terminal Interface Type & Purpose
EtherNet/IP Port RJ45. Used for database connections, Sysmac Studio programming, tag data links, and generic TCP/IP messaging.
EtherCAT Port RJ45. Dedicated master port for high-speed synchronous I/O, servo drives, and vision sensors.
USB Port USB 2.0 Type-B. Direct local interface for system configuration, firmware updates, and offline diagnostics.
SD Card Slot Supports SD/SDHC cards for database spooling buffer, database log storage, and user program backups.

Empirical Engineering Insights

Alternative Models & Compatibility

The NJ101-9020 is a specialized database variant. It differs from the standard NJ101-9000 by including built-in SQL middleware client structures. When replacing a standard NJ101 series processor, ensure that Sysmac Studio has the appropriate database connection license activated to compile the database function blocks (_DB_Insert, _DB_Select, etc.).

Application Pitfalls & Engineering Notes

When utilizing direct-to-database connections, you must install an industrial-grade SD memory card (such as Omron HMC-SD291) to serve as a spooling buffer. Standard commercial SD cards cannot handle the rapid write cycles required during network-offline spooling and will fail prematurely, leading to Event Code 0x14600000 (Spool Memory Overrun). Additionally, ensure that the current draw on the local CJ-series bus does not exceed the capacity of the power supply unit (e.g., NJ-PA3001).

Commissioning & Wiring Tips

Keep the EtherCAT and EtherNet/IP networks logically and physically isolated. Bridging them can lead to network jitter on the EtherCAT cycle, triggering synchronization faults. In Sysmac Studio, always pre-verify the database server credentials and port assignments using the built-in Connection Test Tool before executing program-level connect commands.

Installation Guidelines

CRITICAL WARNING

Isolate all electrical power sources from the control panel before mounting the CPU to the DIN rail or attaching CJ-series expansion modules. Touching active connections or live backplane terminals can result in severe shock or logic board destruction via electrostatic discharge.

1
Mount the CPU onto the DIN rail, ensuring the unit is securely locked in place with the bottom yellow slide locks engaged.
2
Connect the functional ground terminal of the adjacent power supply module to a dedicated class-D ground point (100 Ohm maximum ground impedance).
3
Ensure the power supply modules, CPU, and CJ end plate are locked tight using the integrated slider connectors on each unit.
4
Connect double-shielded Category 5e (or higher) STP cables to the EtherCAT master port and route them away from high-voltage motor cables.
Loading product navigation…

Can the NJ101-9020 write data directly to an SQL database without a computer?

Yes. The NJ101-9020 has a built-in SQL client instruction set that establishes a direct connection to SQL databases like MS SQL, Oracle, and MySQL via the EtherNet/IP port, bypassing any PC middleware.

What happens to the database logs if the factory network drops out?

The module uses an internal spooling mechanism that automatically writes transactional SQL commands to an installed SD memory card. When the network connection is restored, the spooled data is queued and updated in the database.

Can I use standard CJ-series I/O modules with this CPU?

Yes. The NJ101-9020 includes a CJ I/O Bus port on its side, permitting direct backplane mounting of up to 40 CJ-series expansion units.

What software is required to program this CPU?

You must use Sysmac Studio Standard Edition. The database integration settings are configured under the Database Connection CPU Unit Settings section of the software.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Recently Viewed Products

Technical knowledge

Advanced Boolean Logic with FBD PLC Programming: Practical Industrial Applications Beyond Basic Logic

The article explains several advanced Boolean logic functions used in PLC programming beyond basic AND, OR, and NOT operations. It covers how tools like truth tables, multiplexers, pulse generators,...

Boolean Logic in PLC Programming: Understanding FBD Logic Gates

Boolean logic is the foundation of every PLC program. From simple machine controls to complex industrial automation systems, logic gates determine how controllers respond to changing inputs and...

Deep-Dive Guide to Industrial Firewalls and OT Network Segmentation

Industrial firewalls play a critical role in OT cybersecurity, protecting PLC, DCS, and SCADA networks through segmentation, ingress/egress control, and IDS/IPS integration aligned with IEC 62443...

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...