Omron

Omron NS12-TS01-V2 NS Series Programmable Terminal

SKU NS12-TS01-V2

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Omron

  • Product No.: NS12-TS01-V2

  • Country of origin:Japan

  • Product Type: Programmable Terminals

  • Payment: T/T, Western Union

  • Weight: 2500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Integrating the NS12-TS01-V2 human-machine interface (HMI) into industrial automation systems provides operators with high-resolution visualization and intuitive touch control. This Omron NS Series programmable terminal features a 12.1-inch TFT color display, offering clear graphical representations of machine processes, real-time status updates, and interactive control options. Equipped with built-in Ethernet capabilities, it supports seamless integration into plant-wide host networks, facilitating reliable data transmission, PLC communications, and remote system monitoring.

Its robust mechanical construction allows for secure panel mounting in diverse industrial environments. Designed for long-term reliability in manufacturing, processing, and assembly lines, this terminal interfaces seamlessly with Sysmac controllers and standard PLCs to optimize supervisory control systems.

Features

  • High-luminance 12.1-inch TFT color display with a resolution of 800 x 600 dots.
  • Built-in Ethernet port for high-speed network integration, upload/download, and host communications.
  • Durable resistive analog touchscreen facilitating highly responsive operator inputs.
  • Sleek, industrial-grade ivory enclosure designed for clean-room and control cabinet mounting.
  • Compatible with standard Omron programming software for efficient screen design and device configuration.

Applications

  • Automotive assembly and robotic workcell monitoring
  • Packaging, labeling, and material handling systems
  • Water and wastewater treatment facility control consoles
  • Food and beverage processing and batch monitoring
  • Specialized CNC machine tool interfaces

Technical Specifications

Manufacturer Omron
Model / Part Number NS12-TS01-V2
Series NS Series
Display Type 12.1-inch TFT LED backlight
Resolution 800 x 600 dots
Ethernet Port Yes
Case Color Ivory
Rated Power Supply Voltage 24 VDC
Power Consumption 25 W maximum
Storage Temperature -20 to 60 Celsius
Ambient Operating Humidity 35% to 85% (0 to 40 Celsius), 35% to 60% (40 to 50 Celsius) without condensation
Operating Environment No corrosive gases
Weight 2.5 kg maximum

Connections and Interfaces

Interface Type Function / Description
Ethernet (RJ45) 10/100 Base-TX port for host PLC communications and configuration transfers
Serial Ports RS-232C connections for direct PLC interface and peripheral communication
Power Terminal 24 VDC input connection with dedicated grounding terminal

Installation Guidelines

  • Panel Cutout: Mount the HMI in a clean, flat panel cutout, ensuring the waterproof packing seal is properly seated to prevent ingress of dust or moisture.
  • Power & Grounding: Connect a stable 24 VDC power supply to the dedicated terminal. Ground the terminal separately to an independent class-3 ground (100 ohms or less) to minimize electromagnetic interference.
  • Ventilation: Provide at least 100 mm of clearance space around the terminal inside the enclosure to allow natural convection and prevent heat buildup.
  • Atmospheric Conditions: Avoid mounting the device in direct sunlight, highly dusty environments, or areas subject to corrosive chemical gases.

FAQ

What is the display resolution of the Omron NS12-TS01-V2?

The NS12-TS01-V2 features a 12.1-inch TFT display with a resolution of 800 x 600 dots.

What power supply is required for this HMI?

The terminal operates on a rated power supply of 24 VDC, with a maximum power consumption of 25 W.

Does this model support network connectivity?

Yes, this model includes built-in Ethernet port capability for communication and integration into host networks.

What are the storage temperature limits for this device?

The storage temperature range is -20 to 60 Celsius.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Technical knowledge

First TwinCAT PLC Project on a Beckhoff IPC

Build and verify a first TwinCAT PLC project on a Beckhoff IPC. This checklist covers target selection, EtherCAT discovery, I/O mapping, safe activation, restart tests, and commissioning records.

Commissioning OPC UA in KEPServerEX: A Field Checklist

A practical commissioning sequence for KEPServerEX OPC UA connections: define data ownership, test tags locally, configure endpoint and certificate trust, limit access, then verify failure recovery...

Set a PLC Commissioning Laptop IP Without Losing Access

Commissioning an Ethernet-connected PLC often starts with the laptop, not the controller. Learn how to record existing settings, choose a temporary address, test connectivity, and restore the plant...

Designing Automation for Combustible Dust Hazards

Combustible dust controls require more than alarms. Learn how to map dust generation, select instrumentation, design interlocks, handle failed feedback, test safe states, and maintain the full...

Hairpin Stators: Benefits, Limits, and Inspection

Hairpin windings raise slot fill and support compact traction motors, but conductor geometry, AC losses, insulation damage, weld quality, and cooling determine whether the design meets its targets.

Using Ansible for Controlled SCADA Server Changes

Use Ansible to standardize SCADA server changes without expanding OT risk. This guide covers inventories, idempotent playbooks, staged testing, credentials, logging, and practical rollback controls.